Record Power DX1000 Original Instruction Manual

Record Power DX1000 Original Instruction Manual

Fine filter 45 litre extractor

Advertisement

Original Instruction Manual
DX1000
Fine Filter 45 Litre Extractor
Version 3.1
January 2014
It is important to register your product as soon as possible in order to receive efficient after sales
support and be entitled to the full 5 year guarantee. Your statutory rights are not affected.
Kg
Always wear safety glasses when
using woodworking equipment.
To register this product please visit
www.recordpower.info
Please see back cover for contact details.
i
Always read the instructions
provided before using
woodworking equipment.
Kg
Important
For your safety read instructions carefully
before assembling or using this product.
Save this manual for future reference.

Advertisement

Table of Contents
loading

Summary of Contents for Record Power DX1000

  • Page 1 Original Instruction Manual DX1000 Fine Filter 45 Litre Extractor Version 3.1 January 2014 To register this product please visit www.recordpower.info It is important to register your product as soon as possible in order to receive efficient after sales support and be entitled to the full 5 year guarantee. Your statutory rights are not affected.
  • Page 2: Table Of Contents

    Contents 1. Explanation of Symbols 2. General Health & Safety Guidance 3. Additional Health & Safety Guidance for Dust Extractors 4. Record Power Guarantee 5. Specifications 6. Contents of the Package 7. Assembly & Operation 8. Electrical Connection & Wiring Diagram 9.
  • Page 3: Explanation Of Symbols

    1. Explanation of Symbols THE SYMBOLS AND THEIR MEANINGS SHOWN BELOW MAY BE USED THROUGHOUT THIS MANUAL. PLEASE ENSURE THAT YOU TAKE THE APPROPRIATE ACTION WHEREVER THE WARNINGS ARE USED. Mandatory Instructions Warning Read and fully understand the instruction manual Indicates a risk of severe personal injury or before attempting to use the machine.
  • Page 4 2. General Health & Safety Guidance cont. 7. Remove adjusting keys and wrenches circuit, overload and earth leakage protection. • Ensure that all adjusting wrenches and keys are removed before switching • The voltage of the machine must correspond to the voltage of the mains the machine ‘ON’.
  • Page 5 2. General Health & Safety Guidance cont. the relevant section of the manual for details of the specific dust extraction 30. Check for damaged parts requirements for this machine. • Before each use of the machine, it should be carefully checked to determine that it will operate properly and perform its intended function.
  • Page 6: Additional Health & Safety Guidance For Dust Extractors

    3. Additional Health & Safety for Dust Extractors 1. Safe Operation • All Record Power dust extractors are designed solely for use with • Floor standing dust extractors should be positioned on a level floor. wood dust and chippings. Do not use the machine to remove vapours,...
  • Page 7: Record Power Guarantee

    Guarantee This Guarantee does not confer any rights other than those expressly Record Power guarantees that for a period of 5 years from the date of set out above and does not cover any claims for consequential loss or purchase the components of qualifying Products (see clauses 1.2.1 to damage.
  • Page 8: Specifications

    5. Specifications Filtration: 0.5 Micron Capacity: 45 litres Weight: 11 kg Air Flow: 53 litres / second Motor: 1 kW Size: H620 x W530 x D360 mm Sound Pressure: LPA< 75 dB (A) Sound Power: LWA< 85 dB (A) 6. Contents of the Package Inside the shipping container you will find the following: 1.
  • Page 9: Assembly & Operation

    7. Assembly & Operation 1. Attach one end of the flexible hose to the machine inlet and secure with the jubilee clip supplied (Fig 7.1). 2. Place the cartridge filter with open end uppermost inside a paper filter-bag and fold the top edges of the paper bag down inside the cartridge (Fig 7.2).
  • Page 10: Electrical Connection & Wiring Diagram

    Restarting In the Event of a Power Failure In the event of a power failure, first turn the power switch to the off position and In the Event of a Blockage then locate and rectify the source of the failure. If the fault is within the power If a blockage in the collection hose of the machine occurs, switch it off circuit of the workshop, there may be an underlying cause (circuit overload immediately by pressing the power switch to the off position and wait for the...
  • Page 11: Dust Extraction

    20 minutes every hour. 0.5 micron filtration Record Power offer a range of high quality dust extractors, we offer both drum and bag type extractors which filter down 0.5 micron providing protection from harmful fine dusts.
  • Page 12: Maintenance

    10. Maintenance WARNING: Before any type Fig. 10.1 Cartridge of maintenance is carried Filter out, it is important That the machine is switched off and disconnected from the power supply. Replacing the Filters The filters should be inspected every time the unit is emptied and particularly if any reduction in Cartridge performance is noted.
  • Page 13: Parts Diagram & List

    11. Parts Diagram & List...
  • Page 14 11. Parts Diagram & List - Cont. Description Ref. Number Quantity switch KND2-12/2-250V pan head screw M4X10 GB/T818-2000 switch mount plate JMDE0201011101 lid cover JMDE0201011000 M16 strain release JL91046300 power cord 2-B43102200-483 I type hex nut M4 GB/T6170-2000 JMDE0201014000 packing washer JMDE0201040004 motor packing washer JMDE0201040001...
  • Page 15 EU Declaration Of Conformity Cert No: EU / DX1000 / 1 RECORD POWER LIMITED, Centenary House, 11 Midland Way, Barlborough Links, Chesterfield, Derbyshire S43 4XA declares that the machinery described:- Type: High Filtration Dust Extractor Model No: DX1000 Serial No .................
  • Page 16 Woodworking Machinery & Accessories United Kingdom Eire Australia New Zealand Record Power Ltd Record Power Ltd Tools 4 Industry Tools 4 Industry Centenary House, 11 Midland Way Centenary House, 11 Midland Way Po Box 3844 Po Box 276079 Barlborough Links, Chesterfield...