Download Print this page

Phenix Technologies VMS-3 Manual

Portable power supply

Advertisement

Quick Links

PORTABLE POWER SUPPLY
MODEL NUMBER VMS-3
VERSION 1.1
Copyright © Phenix Technologies, Inc.
Rev 10/11/2019 (Format)
VMS-3

Advertisement

loading
Need help?

Need help?

Do you have a question about the VMS-3 and is the answer not in the manual?

Questions and answers

Summary of Contents for Phenix Technologies VMS-3

  • Page 1 PORTABLE POWER SUPPLY MODEL NUMBER VMS-3 VERSION 1.1 Copyright © Phenix Technologies, Inc. Rev 10/11/2019 (Format) VMS-3...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS Section Number DANGER / GENERAL SAFETY PRECAUTIONS INTRODUCTION AND TECHNICAL SPECIFICATIONS CONTROL AND METERING DESCRIPTION OPERATION AND CALIBRATION CIRCUIT DIAGRAM SYMBOLS ELECTRICAL DRAWINGS PARTS LIST RECOMMENDED SPARE PARTS PARTS ORDERING INFORMATION RETURNED MATERIAL CUSTOMER COMMENTS / SUGGESTIONS VMS-3...
  • Page 3 DANGER / WARNINGS WARNING !! Complete Grounding of this unit is necessary for the safe operation of this equipment. Disconnect inputs before ungrounding this equipment VMS-3...
  • Page 4 • DO NOT operate damaged equipment. Remove power, and do not use the equipment until safe operation can be verified by service- trained personnel. Phenix Technologies, Inc. assumes no liability for unsafe or improper use of test equipment. VMS-3...
  • Page 5 The VMS-3 allows the user to dial in an output voltage or current to determine the operational voltage or current levels of various electro-mechanical devices. Both the voltage and current output levels can be simultaneously read and monitored with the highly accurate, onboard meters.
  • Page 6 TECHNICAL SPECIFICATIONS Model: VMS-3 Portable Power Supply Input: 115/120 Volts, 10 Amps, 60 Hz, Single Phase Output: 0-120VAC; 10AAC MAX through binding posts (Will not reach 120VAC with the 115VAC input. Output will be 0-115VAC) 0-150VDC; 5ADC MAX through binding posts...
  • Page 7: Control And Metering Description

    AC/DC Output Selector Switch. Toggle to select either AC or DC output. AC Supply Binding Posts. Connect included output leads here to apply AC voltage to a test object. DC Supply Binding Posts. Connect included output leads here to apply DC voltage to a test object. VMS-3...
  • Page 8 CONTROL AND METERING DESCRIPTION Figure 1: VMS-3 Front Panel                               ...
  • Page 9: Operation And Calibration

    Upon completion of testing, turn off main power by switching off the main breaker before disconnecting the output leads from the test component. WARNING : For safety reasons, dial back the Main Variac knob to its zeroed-out position before and after each use. VMS-3...
  • Page 10 The onboard digital Voltmeters and Ammeters will also hold their normally calibrated settings during the lifetime of your VMS-3 for all normal indoor operations. In the rare case that any meter needs calibration adjustments, the procedure for doing so should be performed by qualified technical personnel such as the Phenix Technologies Service Department during a scheduled service appointment.
  • Page 11: Circuit Diagram Symbols

    SECTION 4: CIRCUIT DIAGRAM SYMBOLS VMS-3...
  • Page 12 SECTION 5: ELECTRICAL DIAGRAMS Drawing Number Description 9907020 VMS-3 Electrical Schematic VMS-3...
  • Page 13: Parts List

    SECTION 6: VMS-3 PARTS LIST PHENIX QTY. ITEM # PART # DESCRIPTION CASE 2100479 CASE BRIDG1 1789205 BRIDGE RECTIFIER PWR CORD 1077164 16/3 PWR CORD 10 FT 1094520 CAPACITOR, 3Uf, 400V 1601310 CKT BRKR 1601423 CKT BRKR CM1 (AC) 1506512...
  • Page 14: Recommended Spare Parts

    PART # DESCRIPTION 1603601 AGC-1 Fuse 1603605 AGC-5 Fuse 1423270 Neon Lamp Amber Output lead wires 1356212 Multilamm Plug Black 1356213 Multilamm Plug Red Gator Clip – 20 Amp 1353042 1353041 Gator Clip Boot Black 1353040 Gator Clip Boot Red VMS-3...
  • Page 15: Parts Ordering Information

    SECTION 8: PARTS ORDERING INFORMATION Replacement parts are available from Phenix Technologies, Inc. Changes to Phenix Technologies' products are sometimes made to accommodate improved components as they become available, and to give you the benefit of the latest technical improvements developed in our Engineering Department. It is, therefore, important when ordering parts to include the serial number of the unit as well as the part number of the replacement part.
  • Page 16: Returned Material

    Serial Number Reason for Return Cause of Defect If Phenix Technologies, Inc. deems return of the part appropriate, it will then issue an "Authorization for Return." If return is not deemed advisable, other inspection arrangements will be made. NOTE: Material received at this plant without the proper authorization shall be held as "Customer's Property"...
  • Page 17: Customer Comments / Suggestions

    10-1 SECTION 10: CUSTOMER COMMENTS/SUGGESTIONS Phenix Technologies made significant efforts to ensure that the materials in this Operator’s Manual are correct. If there are concerns or comments as you have used this information, Phenix Technologies appreciates any feedback. Unit Serial Number:...