Smart Home Systems Installation Manual Help Mode Zones Scenes Events Setup Timer Off in press to set 10hr 30min cool heat myauto medium high myfan V2.1...
1 - SYSTEM OVERVIEW PART NO. OPTIONS DESCRIPTION DK / FJ / LG / ME / PA / BDSAM / TO / Control Box MHI / HIT / TZ / GB / BR / ACT2 / RIN20 EXT8 Extender (MyLights + WSW) CLIP24 Zone Motor PSU-ACDC...
3 - COMPATIBILITY The following table lists the air-conditioner brands the CB9 supports. Some brands require a special version of the CB9 in order to communicate with their units. The part numbers are listed in the second column. BRAND CB PART NO. LINK CABLE ACTRON (ULTRASLIM) LINK C...
4 - CB9 SETUP The standard CB9 Control Box will control units from the following suppliers: • Carrier, Midea, Rinnai, York • Samsung (14kW or less) • Haier Samsung units - LINK A 1. Ensure power to the air conditioner is OFF. 2.
Page 8
4 - CB9 SETUP IMPORTANT: 1. The standard Haier remote must be installed to provide temperature sensing. 2. MyZone functionality is not available for Haier units. 3. The child lock on the Haier wall remote should also be enabled so that the unit can only be controlled through the MyAir controller.
5 - DAIKIN (CB9 DK) SETUP CB9 DK setup steps are as follows: 1. Connect the Daikin wired remote to the indoor unit in the roof space. 2. Power up the air conditioner & run the unit to test correct operation of indoor & outdoor unit.
6 - FUJITSU (CB9 FJ) SETUP CB9 FJ setup steps are as follows: 1. Connect the Fujitsu wired remote to the indoor unit in the roof space. 2. Power up the air conditioner & run the unit to test correct operation of indoor & outdoor unit.
8 - MITSUBISHI ELECTRIC (CB9 ME) SETUP CB9 ME setup steps are as follows: 1. Connect the Mitsubishi wired remote to the indoor unit in the roof space. 2. Power up the air conditioner & run the unit to test correct operation of indoor & outdoor unit.
10 - PANASONIC (CB9 PA) SETUP CB9 PA setup steps are as follows: 1. Connect the Panasonic wired remote to the indoor unit in the roof space. 2. Power up the air conditioner & run the unit to test correct operation of indoor & outdoor unit.
10 - PANASONIC (CB9 PA) SETUP h) Press ENTER button to save. 3. Power off the air conditioner & remove the wired remote control from system 4. Connect the supplied cable from the CB to the indoor unit. Wire the cable cores to the terminals as shown below: CABLE CORE COLOUR INDOOR UNIT TERMINAL...
11 - TOSHIBA (CB9 TO) SETUP 4. Power off the Toshiba air conditioner & remove Toshiba wired remote control from system. 5. Connect the supplied cable from the CB to the indoor unit. Wire the cable cores to the terminals as shown below: CABLE CORE COLOUR INDOOR UNIT TERMINAL BLACK...
12 - HITACHI (CB9 HIT) SETUP e. Press the left or right arrow (tu) to scroll to select the correct option outlined in step #3 above. Press the OK button to enter the new selection. g. Select YES using the left arrow (t) to the question when prompted “Confirm setting of thermistor selection?”...
19 SYSTEM CONFIGURATION to complete install IMPORTANT: 1. At least one Advantage Air temperature sensor is required. 2. MyAir with Temperzone needs to be set up to sense from MyZone. 3. R/A sensing is not compatible. 15 - GREE & BRAEMAR (CB9 GB) CB9 GB for Gree &...
A suitable cable (Supplied by the installer) is run between the Actron outdoor unit and the Advantage Air CB9 ACT2 control box located normally in the roofspace. Additional Items Required: 1 x Actron Model “ICUNO-MOD”...
18 - RINNAI 20kW & 24kW (CB9 RIN20) CB9 RIN20 for RINNAI 20kW & 24kW setup steps are as follows: * Refer to the Rinnai installation manual for the DIP Switch Settings on the indoor unit main board. 1. Connect the wired remote to the indoor unit in the roof space. 2.
19 - SYSTEM CONFIGURATION Now the CB9 (and variants) have been paired to the indoor unit. The following steps will complete the system configuration. IMPORTANT: Due to heat transfer in summer, the CB should be installed at least 1m away from roofing materials, such as roof tiles. 1.
Page 20
19 - SYSTEM CONFIGURATION 5. Power up the air conditioning system. 6. Open the MyPlace app on the home page of the wall mounted touch screen 7. Press the SETUP button 8. Press the TECH SETUP button. 9. Enter password 22369 to access the setup.
20 - PAIRING TEMP SENSOR 1. Remove the wall sensor from the packaging and discard the battery tab. Write zone number and name on white area provided. 2. Take the wall sensors to the wall mounted touch screen. Go to MyAir tab -> Setup ->...
21 - ZONE GROUPING This will group zones together. The follower zone will mimic the state of the primary zone and won’t be shown in the zone page. NOTE: Constant zone and zones with a sensor will not be able to follow other zones.
22 - DATA BACKUP This will restore the following to the wall mounted touchscreen using backup data from your phone: • All zone names • Aircon names / System name in remote access • Lights group and individual names • Place group and individual names •...
Page 25
1 - SYSTEM OVERVIEW MyAir+ allows for an installation to include up to 4 Air Conditioner (AC) units all controlled from the same TSP (touchscreen.) Installation Guide V2.1...
Page 26
2 - MASTER / SLAVE CB There can only be one TSP connected per system. The Master is the CB that is connected to the TSP. NOTE: If MyLights is to be installed the LM’s need to connect to the Master CB and not a Slave CB.
Page 27
3 - HOME SCREEN Once the MyPlace app has been run the MyAir+ tab will display the home screen as shown above. Each icon set represents a single Air Conditioner, pressing in the top left area of the icon will open that Air Conditioning unit.