INTRODUCTION
Dairy Chem Systems are designed to dispense non-foaming dairy cow teat dip products from a chemical storage
vessel to a teat dip spray head or fill valve. VS versions use an external vacuum switch on the pipeline to control
dispensing only when milking lines are in use. Systems with dual-pump configuration can be setup to operate in the
following ways:
Run both pumps simultaneously to inject two different chemicals.
Run one pump at a time, but alternate between pumps at various intervals (using the selector valve on units so
equipped) to extend the life of both pumps.
Run one pump at a time, but only switch pumps when needed (using the selector valve on units so equipped) to
keep one as a spare.
SPECIFICATIONS
Chemical Compatibility
Air Operated Pump Materials
Air Requirements / Consumption
SAFETY PRECAUTIONS
Read and understand the MSDS sheets for the chemicals that will be used — consult your chemical supplier if you
have any questions.
Always wear safety goggles and protective gloves while handling chemicals.
Avoid contact of chemicals with skin and eyes. If contact occurs, rinse affected area with water for 15 minutes, and
seek medical attention, if needed.
MAINTENANCE
Periodically drain the bowl on the air regulator/filter by pushing up the stem on the bottom of the bowl till the water
runs out.
The bowl can be removed (by turning counter-clockwise) to clean the filter element. When replacing the bowl, be
sure that the O-ring is properly positioned on top of the bowl.
0901159 Rev: B (03/05)
INSTRUCTION MANUAL
Santoprene: acids, alkalines, soaps, alcohols, ketones.
Polypropylene Body w/ Santoprene Seals and
Diaphragm.
Minimum 40 PSI / Maximum 80 PSI clean dry air
5-10 SCFM during operation.
Page 1 of 8

Advertisement

loading

Summary of Contents for Idex KNIGHT DAIRY-CHEM

  • Page 1 INSTRUCTION MANUAL INTRODUCTION Dairy Chem Systems are designed to dispense non-foaming dairy cow teat dip products from a chemical storage vessel to a teat dip spray head or fill valve. VS versions use an external vacuum switch on the pipeline to control dispensing only when milking lines are in use.
  • Page 2 INSTALLATION — SINGLE PUMP (1) Select the desired location to mount the control box — should not be more than 6 ft (2 meters) from the floor. (2) Mount the control box using the hardware provided or other mounting hardware as needed. (3) Route the Polyethylene suction and discharge the tubing through the openings in the bottom of the case to quick connect type suction and discharge ports on the air pump.
  • Page 3 SINGLE PUMP 7659101 0901159 Rev: B (03/05) Page 3 of 8...
  • Page 4 INSTALLATION — DUAL PUMP (1) Select the desired location to mount the control box — should not be more than 6 ft (2 meters) from the floor. (2) Mount the control box using the hardware provided or other mounting hardware as needed. (3) Route the Polyethylene suction and discharge the tubing through the openings in the bottom of the case to quick connect type suction and discharge ports on the air pump.
  • Page 5 DUAL PUMP WITH SELECTOR VALVE 7659601 0901159 Rev: B (03/05) Page 5 of 8...
  • Page 6 DUAL PUMP WITH SELECTOR VALVE 7659601 Page 6 of 8 0901159 Rev: B (03/05)
  • Page 7 DUAL PUMP WITH SELECTOR VALVE 7659601 0901159 Rev: B (03/05) Page 7 of 8...
  • Page 8: Warranty

    If all of the above check out okay. Repair or replace the pump. KNIGHT LLC, A Unit of IDEX Corporation World Headquarters: 20531 Crescent Bay Drive, Lake Forest, CA 92630-8825 (USA) TEL: 949-595-4800, FAX: 949-595-4801, www.knightequip.com Atlanta Branch: Toronto Branch:...