EcoSpa ™ Salt Water Spa Sanitisation System Installation and Operating Instructions WARNING: Failure to follow these instructions and comply with all applicable codes may cause serious bodily injury and/or property damage. The installation of this product should be carried out by a person knowledgable in spa pool plumbing requirements following the Installation Instructions provided in this manual.
Installation Instructions ....................4 Setting and Operating the Eco-SpaTM System............6 Eco-SpaTM System Maintenance ................7 Trouble Shooting Guide ..................... 8 Davey Water Products Guarantee ................9 Packing List Please ensure your Eco-SpaTM includes the following components – contact your supplier if unsure:...
IMPORTANT NOTICE FACTORS THAT WILL IMPROVE THE PERFORMANCE & LIFE OF YOUR SALT WATER BROMINATOR PLEASE READ THIS BEFORE OPERATING YOUR BROMINATOR There are THREE main factors that will damage your Brominator and reduce the life of the product. Please monitor the following factors in accordance with your installation & operating instructions. 1.
ECO-SPA INSTALLATION INSTRUCTIONS (Refer to diagram next page) Please ensure the EcoSpa™ Control Unit is mounted a minimum of 3 metres away from the spa water and 1.5 metres above ground level. For a portable ensure easy access. Select mounting point and mark 2 holes 18mm apart. (If the unit is to be mounted to a brick or concrete wall use a masonry drill bit.
Page 5
10. You must change the spa water regularly and add new Eco-Spa Bromine Activator Salt and Pool Salt. The frequency of water changes will be affected will be required. For installations with a Davey Spa Power Controller: labelled “Ozone”. system. Suggested Eco-Spa installation diagram follows, other cell installation dealer.
SETTING AND OPERATING THE ECO-SPA: are balanced then add bromine whilst the spa is running to reach a level of 4ppm Bromine. Verify this with a reliable test kit or seek the advice of your pool & spa professional. Please note the above bromine levels are recommended by Australian Standard AS 3633 for water above 26°C.
In general ORP will be affected in the following ways: Chemical Level ORP Levels Bromine UP DOWN DOWN Combined Chlorine & Bromine UP DOWN Total Dissolved Solids* UP DOWN Temperature UP 10. Please note your EcoSpa™ Cell is a reverse polarity type designed to clean itself periodically.
If you operate the EcoSpa in hard water (high calcium hardness) your cell may build up excessive calcium scale. This can be easily removed by cleaning control box and unscrew the barrel unions from the plumbing. Add 1 part cell in this solution. It should not take more than a few minutes to clean. While the calcium is dissolving off the cell you will notice bubbles.