CARNES VCDK090I Quick Start Manual page 2

In-line ventilators 120v

Advertisement

TYPICAL INSTALLATION
MOUNTING (New Frame Construction)
12" ROUND DUCT
(OUTLET)
Ventilator
Factory-Shipped
In Straight-Through
Discharge Position.
Factory-shipped unit installed in new construction.
MOUNTING (Existing Frame Construction)
12" ROUND DUCT
9-3/8" x 12-3/4" TO
(Outlet)
12" ROUND
TRANSITIONS
FINISHED
CEILING
MATERIAL
CEILING
JOIST
(24" Centers
Shown)
Ventilator Factory-Shipped
In Straight-Through
Discharge Position.
Factory-shipped unit installed in existing construction.
9-3/8" x 12-3/4" TO
12" ROUND TRANSITIONS
CEILING
JOIST
(24" Centers
Shown)
MOUNTING
BRACKETS
12" ROUND DUCT
(Inlet)
MOUNTING
SCREWS
I
VCDK090
TYPICAL INSTALLATION
WIRING - 115V, 60 Hz., 1 Phase
UNIT SIZE
170
130
090
Speed
Control
Use U.L. approved connectors to wire per local codes. Connect
ground wire to bottom of conduit box.
IMPORTANT:
Remove shipping tape from damper.
Remove the shipping tape from the damper flap and make sure
that damper flap opens and closes freely inside the ductwork.
Use duct tape to make ductwork connections secure and air-tight.
DUCTING OPTIONS
BLOWER DISCHARGE POSITIONS
DUCT CONNECTOR
DUCT
CONNECTOR
(Intake)
Horizontal discharge
position. (Factory shipped)
2
MODELS
I
• VCDK130
• VCDK170
WIRE CONNECTION
YELLOW TO L1, ORANGE TO L2
SEPARATE BROWN AND INSULATE
SEPARATE BLUE AND INSULATE
YELLOW TO L1, BROWN TO L2
SEPARATE ORANGE AND INSULATE
SEPARATE BLUE AND INSULATE
YELLOW TO L1, BLUE TO L2
SEPARATE ORANGE AND INSULATE
SEPARATE BROWN AND INSULATE
INSTALL INLINE BETWEEN L2
AND ORANGE, BROWN OR BLUE
CORRESPONDING TO UNIT
SIZE
Housing
Disassembled
(Outlet)
& Rotated To Be
Assembled With
Opening As
Shown
DUCT
CONNECTOR
(Intake)
Vertical discharge
position.
I
DUCT
CONNECTOR
(Outlet)