Advertisement

Quick Links

OWNER'S OPERATION AND INSTALLATION MANUAL
PFS
C
VEADV36NE, VEADV36PE AND VEADV42NE
WARNING: If the information in this manual is not
followed exactly, a fire or explosion may result causing
property damage, personal injury or loss of life.
— Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any other
appliance.
— WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any
phone in your building.
• Immediately call your gas supplier from a neighbor's
phone. Follow the gas supplier's instructions.
• If you cannot reach your gas supplier, call the fire
department.
— Installation and service must be performed by a quali-
fied installer, service agency or the gas supplier.
INSTALLER: Leave this manual with the appliance
CONSUMER: Retain this manual for future reference.
For more information, visit www.fmiproducts.com
DIRECT VENT FIREPLACE
®
US
MODELS
EADV36NE, EADV36PE, EADV42NE,

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the EADV36NE and is the answer not in the manual?

Questions and answers

Summary of Contents for FMI EADV36NE

  • Page 1 DIRECT VENT FIREPLACE OWNER’S OPERATION AND INSTALLATION MANUAL ® MODELS EADV36NE, EADV36PE, EADV42NE, VEADV36NE, VEADV36PE AND VEADV42NE WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
  • Page 2: Table Of Contents

    This fireplace must be installed with pipe and combustion gases are exhausted FMI PRODUCTS, LLC vent pipe components through the inner pipe. If the glass door as- and terminations. sembly and venting pipe are not properly...
  • Page 3 SAFETY Continued affected by carbon monoxide than others. These include pregnant women, people with heart or lung disease or anemia, those under the influence of alcohol and those at high altitudes. Natural and Propane/LP Gas: Natural and propane/LP gas are odorless. An odor-making agent is added to the gas.
  • Page 4: Local Codes

    SAFETY Continued Carefully supervise young children when they are in the room with fireplace. Keep the area around your fireplace clear of combustible materials, gasoline and other flammable vapor or liquids. Do not run fireplace where these are used or stored. 1.
  • Page 5: Product Identification

    PRODUCT IDENTIFICATION 5"/8" Flue Collar Black Porcelain Reflective Panels Glass Door Nailing Flange Glass Pebbles Spacer Control Access Door Black Porcelain Face Trim Figure 1 - Direct Vent Fireplace PRODUCT FEATURES These are a few facts that can help you un- •...
  • Page 6: Pre-Installation

    PRE-INSTALLATION LOCATION AND SPACE • If recessing into a wall, you can avoid extra REQUIREMENTS framing by positioning your fireplace against an already existing framing member. Determine the safest and most efficient loca- tion for your direct vent fireplace. Make sure •...
  • Page 7 PRE-INSTALLATION Continued Maintain 1'' Clearance at Sides NOTICE: This fireplace is intend- and Back of Fireplace ed for use as supplemental heat. Use this fireplace along with your primary heating system. Do not install this fireplace as (36") " " (42") your primary heat source.
  • Page 8 PRE-INSTALLATION Continued 29" (36") 34 3/4" (42") 21 1/8" (36") 25 1/8" (42") 12" (36") 13 3/4" (42") 4 1/2" 20 1/2" (36") 24" (42") 41" (36") 48" (42") 1 1/2" Electrical Outlet Gas Line 44" (36") 48" (42") Access 33"...
  • Page 9: Location Of Termination Cap

    LOCATION OF TERMINATION CAP Fixed Openable Fixed Closed Closed Openable TERMINATION CAP GAS METER RESTRICTED AREA AIR SUPPLY INLET (TERMINATION PROHIBITED) A = clearance above grade, veranda, porch, deck, or I = clearance to service regulator vent outlet [*72" (182.9 cm) balcony [*12"...
  • Page 10: Requirements For The Commonwealth Of Massachusetts

    REQUIREMENTS FOR THE COMMONWEALTH OF MASSACHUSETTS INSPECTION For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or The state or local gas inspector of the side structure used in whole or in part for residential wall horizontally vented gas fueled equipment purposes, including those owned or operated by shall not approve the installation unless, upon...
  • Page 11: Venting Installation

    These models are tested and approved for use with FMI PRODUCTS, LLC (direct vent) INSTALLATION PRECAUTIONS pipe components and terminations. • Wear gloves and safety glasses for The venting system must terminate on the...
  • Page 12 VENTING INSTALLATION Continued INSTALLATION PLANNING etrated is constructed of noncombustible material, such as masonry block or con- There are two basic types of direct vent crete, a 8 " hole with zero clearance is installation: acceptable (see Figure 9). • Horizontal Termination •...
  • Page 13 VENTING INSTALLATION Continued Carefully move fireplace, with vent as- 5. Noncombustible Exterior Wall: Position sembly attached, toward wall and insert horizontal vent cap in center of the 8 " vent pipe into horizontal termination. Pipe round hole and attach to exterior wall overlap should be a minimum of 1 "...
  • Page 14 VENTING INSTALLATION Continued Horizontal Termination Configurations Minimum Siding Pipe Figures 14 and 15, page 15, show a configu- Standoff Overlap ration for venting with horizontal termination Direct Screws with a chart of critical minimum and maximum Vent Pipe dimensions which MUST be met. Wall If using a venting configuration of only hori- Firestop...
  • Page 15 VENTING INSTALLATION Continued GROUND FLOOR INSTALLATION Recommended Applications: • Through the wall using round or square termination • NOT FOR CORNER INSTALLATION 1' Pipe Min On 90° Elbow Horizontal Run Wall Firestop V + 90· Elbow (V) Vertical Required (H) Horizontal Minimum Vertical Pipe Maximum...
  • Page 16 VENTING INSTALLATION Flat Ceiling Installation 1. Cut a 11 " square hole in ceiling using locat- Continued ing hole as a center point. Opening should be Vertical Termination Installation framed to 11 " x 11 " inside dimensions, as shown in Figure 9 on page 12 using framing Note: Vertical restrictor must be installed in lumber the same size as ceiling joists.
  • Page 17 7. Twist-lock vent cap onto last section of If area above is an attic or insulated area, vent pipe. install firestop above framed hole. PARTS LIST FOR VENTING KITS AND COMPONENTS FMI PRODUCTS, LLC (5/8") Pipe & Vent Kits Number Description P58-6 6" Section Double Wall Pipe,...
  • Page 18 VENTING INSTALLATION Continued Vertical Venting V = 40' max. Figure 18 - Vertical Venting Configuration Venting with Two 90° Elbows Vertical (V Horizontal (H) 6' min. 12' max. 7' min. 18' max. 8' min. 20' max. 20' max. 20' max. Figure 19 - Vertical Venting Configuration Using Two 90°...
  • Page 19: Fireplace Installation

    FIREPLACE INSTALLATION CHECK GAS TYPE For propane/LP connection only, the installer Use proper gas type for the fireplace unit you must supply an external regulator. The exter- are installing. If you have conflicting gas types, nal regulator will reduce incoming gas pres- do not install fireplace.
  • Page 20 FIREPLACE INSTALLATION Continued Check your building codes for any special WARNING: Use pipe joint requirements for locating equipment shutoff valve to fireplaces. sealant that is resistant to liquid Apply pipe joint sealant lightly to male NPT petroleum (LP) gas. threads. This will prevent excess sealant from going into pipe.
  • Page 21 FIREPLACE INSTALLATION Continued CHECKING GAS CONNECTIONS 3. Check all joints from propane/LP supply tank or gas meter to equipment shutoff WARNING: Test all gas piping valve (see Figure 24 or Figure 25). Apply noncorrosive leak detection fluid to all and connections, internal and joints.
  • Page 22 FIREPLACE INSTALLATION Continued 3. Make sure control knob of fireplace is in Removing Glass Door the OFF position. If replacement of glass is necessary, the entire frame assembly must be replaced. Gloves 4. Check all joints from equipment shutoff must be worn when removing/replacing glass valve to gas valve (see Figure 24 or door.
  • Page 23 FIREPLACE INSTALLATION Continued Connecting and Disconnecting Gas Line Remove face trim, control access door and glass door (see Removing/Replacing WARNING: A qualified ser- Glass Door, page 22). vice person must connect and 2. Remove glass pebbles. disconnect fireplace with gas 3.
  • Page 24: Operation

    OPERATION FOR YOUR SAFETY 4. Remove face trim pieces and control ac- cess door. READ BEFORE LIGHTING 5. Turn equipment shutoff valve clockwise WARNING: If you do not fol- to the OFF position (see Figure 29). Do not force. low these instructions exactly, 6.
  • Page 25: Gas Control Module System

    OPERATION Continued MANUAL LIGHTING Continuous Pilot ADJ. Remote/Off Switch Off/On Switch PROCEDURE 1. Set the switch on the side of the module (see Figure 30) that reads REMOTE/OFF to the OFF position. 2. The fireplace will operate from the ON/ “S”...
  • Page 26: Inspecting Burners

    OPERATION Continued BATTERY BACK-UP NOTE: The module must be programmed to the Remote Control transmitter. This fireplace is equipped with a battery back- • To program the module (make sure the up. If the power was to go out on the fireplace, system has power), locate the learn button the battery back-up allows the fireplace to (Figure 31, page 5) on the module.
  • Page 27 CLEANING AND MAINTENANCE Continued Glass must be cleaned periodically. During start-up it is normal for condensation to form WARNING: Do not operate on the inside of the glass causing lint, dust and fireplace with glass door un- other airborne particles to cling to the glass latched, removed, cracked or surface.
  • Page 28: Troubleshooting

    TROUBLESHOOTING WARNING: Turn off fireplace and let cool before servicing. Only a qualified service person should service and repair fireplace. CAUTION: Never use a wire, needle or similar object to clean pilot. This can damage pilot unit. Note: All troubleshooting items are listed in order of operation. OBSERVED PROBLEM POSSIBLE CAUSE REMEDY...
  • Page 29 TROUBLESHOOTING Continued OBSERVED PROBLEM POSSIBLE CAUSE REMEDY Pilot will not stay lit 1. Loose wiring on ignitor wire 1. Confirm the "S" wire and to ignition module and/ the "I" wire are properly or poor ground to ignition connected to the module module in the proper "S"...
  • Page 30 TROUBLESHOOTING Continued WARNING: If you smell gas • Shut off gas supply. • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor’s phone. Fol- low the gas supplier’s instructions.
  • Page 31: Specifications

    SPECIFICATIONS (V)EADV36NE (V)EADV36PE • Rating: 36,000/23,000 Btu/hr • Rating: 47,000/27,000 Btu/hr • Gas Type: Propane/LP Gas Only • Gas Type: Natural Gas Only • Ignition: Electronic • Ignition: Electronic • Manifold Pressure: 10" w.c. • Manifold Pressure: 3.5" w.c. • Minimum Inlet Supply Pressure: 11" w.c.
  • Page 32: Parts

    PARTS MODELS (V)EADV36NE, (V)EADV36PE AND (V)EADV42NE www.fmiproducts.com 125996-01C...
  • Page 33 PARTS This list contains replaceable parts used in your fireplace. When ordering parts, follow the instructions listed under Replacement Parts on page 37 of this manual. PART NO. DESCRIPTION 125105-01 Door Assembly, 36" • • 125105-02 Door Assembly, 42" • 125103-01 Control Access Door Assembly, 36"...
  • Page 34 PARTS MODELS (V)EADV36NE, (V)EADV36PE AND (V)EADV42NE www.fmiproducts.com 125996-01C...
  • Page 35 PARTS BURNER ASSEMBLY This list contains replaceable parts used in your fireplace. When ordering parts, follow the instructions listed under Replacement Parts on page 37 of this manual. " " " NO. PART NO. DESCRIPTION NG 36 LP 42 NG QTY. 126027-01 Burner Pan Assembly, 36"...
  • Page 36 PARTS MODELS (V)EADV36NE, (V)EADV36PE AND (V)EADV42NE This list contains replaceable parts used in your fireplace. When ordering parts, follow the instructions listed under Replacement Parts on page 37 of this manual. NO. PART NO. DESCRIPTION 125861-01P Panel, Rear, Porcelain 36'' •...
  • Page 37: Replacement Parts

    When Gas Pressure Is Too Low installation, operation, or troubleshooting. • pilot will not stay lit If so, contact FMI PRODUCTS, LLC at • burners will have delayed ignition 1-866-328-4537. When calling please have • fireplace will not produce specified heat your model and serial numbers of your •...
  • Page 38 NOTES _____________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ _____________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ _____________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ www.fmiproducts.com 125996-01C...
  • Page 39 NOTES _____________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ _____________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ _____________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ www.fmiproducts.com 125996-01C...
  • Page 40: Warranty

    FMI PRODUCTS, LLC’s liability is limited to the purchase price of the product, and FMI PRODUCTS, LLC shall not be liable for any other damages whatsoever under any circumstances including indirect, incidental, or consequential damages.

This manual is also suitable for:

Eadv36peEadv42neVeadv36neVeadv36peVeadv42ne

Table of Contents