SPCO VM Installation And Operating Instructions Manual

SPCO VM Installation And Operating Instructions Manual

Vertical multistage centrifugal pump, 50hz

Advertisement

®
Installation and operating instructions
VM, VMC, VMN
Vertical Multistage
Centrifugal Pump, 50Hz

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the VM and is the answer not in the manual?

Questions and answers

Summary of Contents for SPCO VM

  • Page 1 ® Installation and operating instructions VM, VMC, VMN Vertical Multistage Centrifugal Pump, 50Hz...
  • Page 2 For the following equipment: Product: Pump Trademark: Vertical Multistage Pump Type Designation: VM, VMC, VMN Manufacture’s Name: Swiss Pump Company AG Manufacture’s Address: Moosweg 36, CH-3645, Thun-Gwatt -Switzerland is herewith confirmed to comply with the requirements set out in the Directive 2014/35/EU And the Machinery Directive 2006/42/EC and Electromagnetic Directive 2014/30/EU.
  • Page 3: Table Of Contents

    Contents Handling page Applications Pump liquids Technical data Definition of model Min. inlet pressure NPSH Min. nominal flow rate Max. inlet pressure and operating pressure Installation Electrical connection Start-up Maintenance Coupling adjustments Troubleshooting ®...
  • Page 4: Handling

    Contact your supplier or the factory for information about special pump versions and applications. Applications VM, VMC, VMN series in-line pumps booster pumps are designed for a wide range of applications in various industries for water treatment, water boosting, water supply, cooling, cleaning, etc.
  • Page 5: Min. Inlet Pressure Npsh

    Minimum inlet pressure NPSH To avoid cavitation, make sure that there is a minimum pressure on the suction side of the pump. NPSHA: Net Positive Suction head Available The net positive suction head available is a function of the pump suction system. NPSHR: Net Positive Suction head required The net positive suction head required is a function of the pump design at the operating point on the pump...
  • Page 6: Max. Inlet Pressure And Operating Pressure

    Maximum Inlet Pressure and Operating Pressure Maximum Inlet Pressure and Operating Pressure - 50Hz 50Hz...
  • Page 7 Maximum Inlet Pressure and Operating Pressure - 50Hz Stage Max. inlet pressure Stage Max. operating pressure VM, VMC, VMN 120 10 bar 30 bar 2-(5-1) 15 bar (6-1)-7 20 bar VM, VMC, VMN 150 (1-1)-1 10 bar (1-1)-6 30 bar...
  • Page 8 Maximum Inlet Pressure and Operating Pressure - 60Hz 60Hz...
  • Page 9 30 bar (5-2)-6 20 bar Maximum Inlet Pressure and Operating Pressure - 60Hz Stage Max. inlet pressure Stage Max. operating pressure VM, VMC, VMN 120 10 bar (2-2)-(3-1) 15 bar 1-(5-2) 30 bar 3-(5-2) 20 bar VM, VMC, VMN 150...
  • Page 10: Installation

    Installation Always refer to the local or national regulations and codes relating to the selection of the installation site, the water and power connections, etc. Position Pumps should be installed in a protected environment, not exposed to weather. Make sure that there are no obstructions to prevent proper motor cooling. Anchoring The pump must be secured to a solid foundation by bolts through the holes in the flange or base plate.
  • Page 11: Electrical Connection

    Description If it is necessary to increase the diameter of the suction pipe, place an eccentric reducer between the check valve and the flexible pipe section. Using elbows will increase the flow resistance. Wide bends will result in lesser flow resistance. 10 The piping must have a level or positive gradient to prevent the formation of air pockets.
  • Page 12 For VM, VMC, VMN 1, 3, 5 series For these pumps, it is advisable to open the bypass valve during start-up. The bypass valve connects the suction and discharge sides of the pump, thus making the filling procedure easier. When the operation is stable, the bypass valve can be closed.
  • Page 13: Maintenance

    If not, then the motor does not require regular maintenance. • If the pump and motor are used infrequently with long intervals of non-operation, then we recommend that the motor be greased. VM, VMC, VMN 1, 3, 5 Coupling adjustments  VM, VMC, VMN 1, 3, 5 Coupling adjustments ...
  • Page 14: Coupling Adjustments

    VM, VMC, VMN 10, 15, 20 Coupling adjustments VM, VMC, VMN 10, 15, 20 Coupling adjustments...
  • Page 15 VM, VMC, VMN 32, 45, 64, 90 Coupling adjustments VM, VMC, VMN 32, 45, 64, 90 Coupling adjustments ®...
  • Page 16: Troubleshooting

    Troubleshooting Fault Cause Solution Check connections or restart the Supply failure or no power supply power supply Main contacts in motor starter are not Reconnect or replace contacts or making contact or the motor coils are magnetic coil defective Pump or piping system may be Clean the obstruction and restart obstructed causing a jam pump...
  • Page 17 Fault Cause Solution Fill the pump with the liquid to be Pump is not primed with liquid pumped The pump, suction or discharge pipes Clean the pump, suction or discharge are blocked by solids in the liquid pipe being pumped The foot or check valve is blocked or Replace the foot or check valve has failed...
  • Page 18 Swiss Pump Company AG Moosweg 36 CH - 3645 Thun - Gwatt Switzerland Tel. +41 33 223 11 00 Fax +41 33 223 11 22 mail@swisspump.com www.swisspump.com...