Advertisement

Quick Links

OPERATION MANUAL & PARTS LIST
MODELS:
CE10 HORIZONTAL TANK SERIES
60/60, 100/100, 150/150,
200/200, 250/250, 300/300

Advertisement

Table of Contents
loading

Summary of Contents for CECOR CE10 Series

  • Page 1 OPERATION MANUAL & PARTS LIST MODELS: CE10 HORIZONTAL TANK SERIES 60/60, 100/100, 150/150, 200/200, 250/250, 300/300...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS SECTION 1 – SAFETY INFORMATION ......................4 1.1 – CAUTION ............................4 1.2 – PRECAUTIONS ..........................5 SECTION 2 – THE SUMP CLEANER ......................... 6 2.1 – UNIT IDENTIFICATION ........................6 2.2 – MODEL & SERIAL NUMBER ......................7 2.3 –...
  • Page 3 7.5 – F23 FILTER ............................37 SECTION 8 – WARRANTY ..........................38 SECTION 9 – RECORD MODEL & SERIAL NUMBER ..................39 CE10 OPERATIONS MANUAL & PARTS LIST (Rev. 6/2021)
  • Page 4: Section 1 - Safety Information

    SECTION 1 – SAFETY INFORMATION 1.1 – CAUTION CAUTION FLAMMABLE THIS EQUIPMENT IS INTENDED FOR USE WITH STANDARD METALWORKING FLUIDS (WATER-BASE & CUTTING OILS) INFLAMMABLE ONLY. IT SHOULD NOT BE USED WITH FLAMMABLE FLUIDS, (FUELS, PAINT, SOLVENTS, ETC.) CORROSIVE, TOXIC OR REACTIVE MATERIALS.
  • Page 5: Precautions

    1.2 – PRECAUTIONS  READ THROUGH THE "OPERATIONS MANUAL" COMPLETELY BEFORE ATTEMPTING TO OPERATE THE MACHINE.  CLEANOUT, POT LID, INLET CAP AND HOSES MUST BE IN PLACE AND TIGHTLY SECURED BEFORE OPERATION IN THE DISCHARGE MODE.  TANK DISCHARGE PRESSURE MUST NOT EXCEED 10 PSI. REGULATOR AND RELIEF VALVES ARE SET BEFORE SHIPMENT AND SHOULD NOT BE CHANGED AS THE USE OF EXCESSIVE PRESSURE COULD CAUSE SERIOUS INJURY OR DAMAGE.
  • Page 6: Section 2 - The Sump Cleaner

    SECTION 2 – THE SUMP CLEANER 2.1 – UNIT IDENTIFICATION WHEN ORDERING PARTS OR ASKING QUESTIONS REGARDING YOUR SUMP SHARK, IT IS IMPORTANT TO HAVE THE MODEL AND SERIAL NUMBER OF THE UNIT. THE MODEL AND SERIAL NUMBER CAN BE FOUND ON THE SHARK’S NAMEPLATE LOCATED ON THE BACK PANEL OF THE PUMP BASE.
  • Page 7: Model & Serial Number

    2.2 – MODEL & SERIAL NUMBER THE MODEL NUMBER IDENTIFIES YOUR SHARK AND INDICATES STANDARD FEATURES ON YOUR MACHINE. THE SERIAL NUMBER IDENTIFIES YOUR SPECIFIC SHARK AND WILL HELP IDENTIFY ANY SPECIAL FEATURES THAT MAY BE UNIQUE TO YOUR SUMP SHARK. THE SERIAL NUMBER IS LOCATED ON THE NAMEPLATE.
  • Page 8: Sump Cleanper Features

    2.3 – SUMP CLEANPER FEATURES PUMP-TO-TANK PUMP-TO-TANK OILER SUCTION DISCHARGE CONNECTION CONNECTION DIRTY TANK SUCTION PORT CLEAN TANK FILL HATCH DIRTY TANK CLEAN TANK DISCHARGE ON / OFF DISCHARGE PORT SWITCH PORT VACUUM/ PRESSURE GAUGE CE10 OPERATIONS MANUAL & PARTS LIST (Rev.
  • Page 9: Section 3 - Installation

    SECTION 3 – INSTALLATION 3.1 – ASSEMBLE DISCHARGE CONNECTION FOR SHIPPING PURPOSE, SOME MODELS MAY REQUIRE THE INSTALL OF THE DISCHARGE VALVE AND QUICK DISCONNECT ADAPTER. USE PIPE SEALANT ON ALL JOINTS AND TIGHTEN SECURELY. CE10 OPERATIONS MANUAL & PARTS LIST (Rev.
  • Page 10: Check Oil Level

    3.2 – CHECK OIL LEVEL INSTALL THE OIL RESERVOIR IN THE TOP OF THE PUMP. TO FILL THE OIL RESERVOIR, REMOVE THE KNURLED PLUG ON THE TOP OF THE RESERVOIR AND FILL THROUGH THE SMALL TOP FILL PORT TO JUST BELOW THE AIR EQUALIZING TUBE OPENING.
  • Page 11 POLY STRAINER BAG FINE COARSE STRAINER BAG STRAINER BAG FLARE NOZZLE DISPENSER NOZZLE STRAIGHT NOZZLE DISPENSER HOSE FLEX NOZZLE QUICK DISCONNECT COUPLER CLEANOUT DOOR (90-200) SUMP QUICK F10 BASKET CLEANER DISCONNECT ASSEMBLY HOSE COUPLER CE10 OPERATIONS MANUAL & PARTS LIST (Rev.
  • Page 12: Initial Startup

    3.4 – INITIAL STARTUP 1. CLOSE AND SECURE ALL TANK SUCTION AND DISCHARGE PORTS. DIRTY TANK SUCTION CLEAN TANK PORT FILL HATCH DIRTY TANK CLEAN TANK DISCHARGE DISCHARGE PORT PORT 2. PLUG IN POWER CORD TO PROPER ELECTRICAL CIRCUIT. SEE NAMEPLATE.
  • Page 13 RUN THE UNIT IN “SUCTION” MODE. WITH POWER SWITCH IN THE OFF, POSITION CONNECT THE PUMP-TO-TANK HOSE TO THE SUCTION CONNECTION. 4. TURN THE POWER SWITCH TO ON. THE VACUUM READING SHOULD INCREASE TO 15-17” HG. 5. TURN SWITCH OFF. THE NEGATIVE PRESSURE IN THE TANK WILL CAUSE THE PUMP TO ROTATE BACKWARDS UNTIL THE PRESSURE EQUALIZES.
  • Page 14 RUN THE UNIT IN “DISCHARGE” MODE. CHANGE THE PUMP-TO-TANK HOSE TO DISCHARGE CONNECTION. 7. TURN THE POWER SWITCH TO ON. THE PRESSURE READING SHOULD INCREASE TO 5-7 PSI. 8. TURN SWITCH OFF. THE POSITIVE PRESSURE IN THE TANK WILL CAUSE THE PUMP TO ROTATE BACKWARDS UNTIL THE PRESSURE EQUALIZES.
  • Page 15: Section 4 - Operation

    SECTION 4 – OPERATION 4.1 – CLEANING A SUMP 1. ATTACH THE SUMP CLEANER HOSE TO THE DIRTY TANK SUCTION PORT, AND INSERT SUCTION TOOL INTO HOSE END. 2. RUN UNIT ON SUCTION MODE. (SEE INITIAL STARTUP 3.5, STEP 3.) 3.
  • Page 16: Discharging Fluid From The Sump Cleaner

    4.2 – DISCHARGING FLUID FROM THE SUMP CLEANER DIRTY TANK 1. ATTACH THE SUMP CLEANER HOSE TO THE DIRTY TANK DISCHARGE PORT, AND CAP THE SUCTION PORT. 2. RUN UNIT ON DISCHARGE MODE. (SEE INITIAL STARTUP 3.5, STEP 6.) 3. POINT NOZZLE AT THE TARGET WHERE THE FLUID IS TO BE DISPENSED, SLOWLY OPEN DIRTY TANK DISCHARGE VALVE.
  • Page 17 4.3 – FILLING CLEAN TANK WITH FLUID 1. WHILE UNIT IS SHUT OFF OPEN 6” FILL HATCH AND FILL CLEAN TANK. 4.4 – DISPENSING FLUID FROM THE SUMP CLEANER CLEAN TANK 1. ATTACH DISPENSER HOSE ASSEMBLY TO THE CLEAN TANK DISCHARGE PORT.
  • Page 18: Filter

    4.3 – FILTER 1. FILTERING OF THE FLUID IS SPECIFIC TO YOU. SUMP CONDITIONS VARY DUE TO ALL THE VARIABLES THAT OCCUR IN A MACHINE-TOOL SUMP. WE INCLUDE MULTIPLE FILTER BAGS SO YOU CAN FIND WHAT WORKS BEST FOR YOUR APPLICATION. FIRST-CLEANING CAN BE ESPECIALLY DIFFICULT IF IT HAS NOT BEEN DONE ON A REGULAR BASIS.
  • Page 19 4.3.1.2 – INSTALLING FILTER 1. PLACE EMPTY FILTER IN METAL PERFORATED BASKET. 2. TUCK HANDLES IN BETWEEN FILTER AND PERFORATED BASKET. MAKE SURE COTTON BANDING(POLY-FILTER) OR SIDES OF FILTER ARE LYING ON POT LID GASKET COMPLETELY WITHOUT CREASES. 3. RE-INSTALL POT LID AND WING NUTS. 5.
  • Page 20: F23 Filter

    4.3.2 – F23 FILTER 4.3.2.1 – EMPTYING FILTER 1. FOR BEST RESULTS, DISCHARGE LIQUID FROM SUMP CLEANER AND LET FILTER DRAIN FOR A FEW MINUTES BEFORE DUMPING. 2. LOOSEN THE THREE WING NUTS ON FILTER ASSEMBLY. 3. LIFT FILTER OUT OF SUMP CLEANER TANK USING HOIST OR FORKLIFT. CAUTION: KEEP HANDS AND FINGERS CLEAR OF POT OPENING IN SUMP CLEANER WHEN REMOVING FILTER! CE10 OPERATIONS MANUAL &...
  • Page 21 4. POSITION FILTER ABOVE CONTAINER INTO WHICH THE SLUDGE IS TO BE EMPTIED. DISTANCE BETWEEN BOTTOM OF FILTER AND CONTAINER BOTTOM OR “D” DIMENSION, SHOWN IN FIGURE BELOW, AND SHOULD BE APPROXIMATELY 2 TO 3 FEET ON F23 TO PREVENT DAMAGE TO FILTER SLEEVE WHEN DUMPED.
  • Page 22 5. ATTACH LANYARD TO TRIGGER ASSEMBLY ON FILTER BOTTOM. 6. MOVE TO A SAFE DISTANCE FROM THE DUMPING ZONE (APPROXIMATELY 7 FEET). 7. PULL LANYARD TO RELEASE LATCH AND BOTTOM DOOR WILL OPEN DUMPING THE FILTER. 8. AFTER FILTER SLEEVE IS EMPTY, ROLL BOTTOM OF SLEEVE UP LOOSELY SO THAT THE BOTTOM END OF SLEEVE WILL BE CLOSED AND CLOSE BOTTOM DOOR.
  • Page 23 4.3.2.2 – INSTALLING FILTER 1. LOOSEN THE TWO WING NUTS ON THE FILTER LID AND REMOVE LID. 2. PLACE BOTTOM END OF FILTER SLEEVE IN FILTER. 3. FOLD UPPER 1 ½” OF FILTER SLEEVE COLLAR OUT OVER LIP OF FILTER SO THAT THE GASKET IN LID WILL CLAMP IT IN PLACE.
  • Page 24: Cleaning The Sump Cleaner

    4.4 – CLEANING THE SUMP CLEANER 1. GENERALLY, DISCHARGING THE FLUID OUT OF THE SUMP CLEANER IS ALL THAT’S NEEDED. SOME SOLIDS WILL ACCUMULATE IN THE BOTTOM OF THE SUMP AND WILL REQUIRE A COMPLETE CLEANOUT OCCASIONALLY. 2. THE SE10 HAS AN EASY TO REMOVE CLEANOUT DOOR AND CAN ACCESSED BY LOOSENING THE TWO WINGNUTS.
  • Page 25 WING NUTS CE10 OPERATIONS MANUAL & PARTS LIST (Rev. 6/2021)
  • Page 26: Section 5 - Maintenance

    THAT WILL KEEP YOUR SUMP CLEANER IN TOP-NOTCH, DEPENDABLE CONDITION. ANY WORN OR DAMAGED PART SHOULD BE REPLACED IMMEDIATELY. CECOR STOCKS SUMP CLEANER PARTS AND MOST CAN BE SHIPPED THE SAME OR THE NEXT DAY. CALL 1-800-356-9042 TO ORDER PARTS.
  • Page 27: Monthly Maintenance

    5.3 – MONTHLY MAINTENANCE 1. CHECK FOR WEAR ON POT LID WING NUTS AND STUDS. 2. INSPECT SUMP CLEANER HOSE. 3. GREASE THE SWIVEL CASTER AND WHEELS. CE10 OPERATIONS MANUAL & PARTS LIST (Rev. 6/2021)
  • Page 28: Section 6 - Troubleshooting

    SECTION 6 – TROUBLESHOOTING PROBLEM POSSIBLE CAUSES CORRECTIVE ACTION WILL NOT START POWER SUPPLY. MAKE SURE THE UNIT IS PLUGGED INTO THE PROPER VOLTAGE. CIRCUIT BREAKER. CHECK ELECTRICAL SUPPLY FUSES OR BREAKER. LOSS OF SUCTION VAC/PRES GAUGE READS CHECK FILTER. IF FULL, EMPTY. IF BLINDED, FULL VACUUM BUT HAS CLEAN OR REPLACE WITH COARSE FILTER NO SUCTION.
  • Page 29: Section 7 - Repair Parts List

    SECTION 7 – REPAIR PARTS LIST 7.1 – WHEELS & CASTER 7.1.1 “PTL” PUSH TOW LIFT WHEEL TRANSPORT 60/60-100/100 GAL Part No. Description SP-365 SWIVEL CASTER WITH POLY TIRED WHEEL SP-553 WHEEL POLY TIRED CE10 OPERATIONS MANUAL & PARTS LIST (Rev.
  • Page 30: Tw" Tow Wheel Transport 300 & 400 Gal

    7.1.3 “TW” TOW WHEEL TRANSPORT 150/150 & 200/200 GAL Part No. Description SP-270 SWIVEL CASTER WITH RUBBER TIRE SP-271 WHEEL WITH RUBBER TIRE CE10 OPERATIONS MANUAL & PARTS LIST (Rev. 6/2021)
  • Page 31: Tw" Tow Wheel Transport 500 Gal

    7.1.4 “TW” TOW WHEEL TRANSPORT 250/250 GAL Part No. Description SP-270 SWIVEL CASTER WITH RUBBER TIRE SP-275 WHEEL WITH RUBBER TIRE CE10 OPERATIONS MANUAL & PARTS LIST (Rev. 6/2021)
  • Page 32: Tank & Pump

    7.2 – TANK & PUMP 10,11 Part No. Description TANK ASSEMBLY CALL FOR INFO (NEED TO SPECIFY GALLON CAPACITY AND TRANSPORT) A220-817 H-TANK PUMP ASSEMBLY E10 A220-153 PUMP-TO-TANK HOSE SP-300(3/4) DISCONNECT ADAPTER SP-301(3/4) DISCONNECT COUPLER SP-302(3/4) COUPLER GASKET CE10 OPERATIONS MANUAL & PARTS LIST (Rev.
  • Page 33: Filter, Tools & Hose

    7.3 – FILTER, TOOLS & HOSE 20,21 20,21 Part No. Description B210-530 POLY STRAINER BAG 1 cu.ft. A210-529C COARSE STRAINER BAG 1 cu.ft. A210-529F FINE STRAINER BAG 1 cu.ft. A220-149 FLARE NOZZLE A210-474 STRAIGHT NOZZLE A220-150 FLEX NOZZLE A220-562 DISPENSER NOZZLE DIPSENSER HOSE 16’...
  • Page 34: Tank Connections, Gauge, Pump Consumables

    7.4 – TANK CONNECTIONS, GAUGE, PUMP CONSUMABLES 27,21 CE10 OPERATIONS MANUAL & PARTS LIST (Rev. 6/2021)
  • Page 35 Part No. Description A210-305 POT LID GASKET SP-373 SECURITY CHAIN SP-104 WING NUT SP-611 PRESSURE SAFE CAP SP-612 PRESSURE SAFE QUICK DISCONNECT ADAPTER SP-437K PRESSURE RELIEF VALVE WITH ELBOW SP-412 OIL RESERVOIR SP-334 PRESSURE RELIEF VALVE SP-194 VACUUM / PRESSURE GAUGE SP-379 FILL HATCH GASKET CONTROL BOX...
  • Page 36 90-200 ONLY 43,44 300-600 ONLY Part No. Description A210-165 CLEANOUT DOOR GASKET A220-240 CLEANOUT DOOR ASSEMBLY A210-305 POT LID GASKET CE10 OPERATIONS MANUAL & PARTS LIST (Rev. 6/2021)
  • Page 37 7.5 – F23 FILTER 50,51 Ref Part No. Description SP-104 WING NUT A220-102 FILTER LID GASKET A220-103 FILTER LID ASSEMBLY SP-612 PRESSURE SAFE QUICK DISCONNECT ADAPTER SP-373 SECURITY CHAIN SP-611 PRESSURE SAFE CAP SP-262BN-2 COUPLER GASKET A220-645 F23 FILTER SLEEVE COARSE (NOT SHOWN) A220-101 F23 FILTER SLEEVE GREEN POLY (NOT SHOWN) A220-731...
  • Page 38 SECTION 8 – WARRANTY WARRANTY STATEMENT PLEASE PRINT OUR WARRANTY AT HTTPS://CECOR.NET/CECOR-WARRANTY/ CE10 OPERATIONS MANUAL & PARTS LIST (Rev. 6/2021)
  • Page 39 SECTION 9 – RECORD MODEL & SERIAL NUMBER WHEN YOU RECEIVE YOUR CECOR SUMP SHARK, RECORD THE MODEL NUMBER, SERIAL NUMBER AND DATE DELIVERED FOR YOUR RECORDS. MODEL #: ________________________________________ SERIAL #: ________________________________________ DELIVERED: ____________ / ____________ / ____________ CE10 OPERATIONS MANUAL & PARTS LIST...
  • Page 40 CE10 OPERATIONS MANUAL & PARTS LIST (Rev. 6/2021)

Table of Contents