translation of original operating manual
edition 1.b
May 2021
destination countries:
gas-fired convection room heater
BP
BL
G2.350
G20
operating manual
DEFRO HOME VITAL
37 S
U
C
gas type
G27
G31
51 S
T
G30

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the VITAL 37S and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Defro Home VITAL 37S

  • Page 1 DEFRO HOME VITAL 37 S 51 S gas type G2.350 translation of original operating manual edition 1.b May 2021 destination countries:...
  • Page 2 że produkt / with all responsibility, that the product konwekcyjny ogrzewacz pomieszczeń opalany gazem / independent gas-fired convection heater (typ/type) DEFRO HOME VITAL 6,0 kW DEFRO HOME VITAL 5,5 kW typ urządzenia: C11, C31, C91 został zaprojektowany, wyprodukowany i wprowadzony na rynek zgodnie z następującymi...
  • Page 3 Dear Customer, Dear Customer, We would like to thank you for choosing the high quality DEFRO We would like to inform you that we make every efforts to offer product which will ensure your safety and operational reliability. products of quality fulfilling the most restrictive standards and As our customers, you can always count on the help of the DEFRO warranting operational safety.
  • Page 4: Table Of Contents

    TABLE OF CONTENTS INFORMATION ......................................6 BASIC SAFETY RULES ..................................... 6 2.1. Safety warnings ....................................6 2.2. Warnings related to operation ................................6 INTENDED USE ......................................7 TECHNICAL SPECIFICATION ................................... 7 4.1. Design ......................................7 4.2. Technical data ....................................8 4.3.
  • Page 5 10.2. Flue gas escape .....................................34 10.3. Carbon monoxide escape................................34 11. TROUBLESHOOTING ....................................34 12. REMOVAL DUE TO WEAR-OUT ................................34 13. PRODUCT WARRANTY TERMS AND CONDITIONS ..........................35 13.1. Warranty conditions “48h Service” ..............................36 14. WARRANTY CARD ....................................37 15. CARRIED OUT WARRANTY REPAIRS AND MAINTENANCE........................38 16.
  • Page 6: Information

    2. BASIC SAFETY RULES 1. INFORMATION 2.1. SAFETY WARNINGS Operating manual is an integral and essential part of the product The national and local provisions should be met. and must be forwarded to the user also in case when the property is Equipment should be installed in compliance with the transmitted.
  • Page 7: Intended Use

    Picture 1 Design of DEFRO HOME VITAL heater. 1 - explosion relief vents, 2 - window panel, 3 - end cap of gland for gas lines, 4 - adjustable feet, 5 - flue, 6 - panels of combustion chamber, 7 - set of control burner, spark igniter and temperature sensor, 8 - primary burner, 9 - combustion air inlets.
  • Page 8: Technical Data

    Connector of control burner 6 mm Mounting position vertical or within the angle from 0° to 90º from vertical position Ø150 Ø150 Picture 2. Dimensions of DEFRO HOME VITAL 37 S. Picture 3.3 Dimensions of DEFRO HOME VITAL 37 S U.
  • Page 9 Picture 5 Dimensions of DEFRO HOME VITAL 37 S T. Ø150 Ø150 Picture 6 Dimensions of DEFRO HOME VITAL 37 S BP and DEFRO HOME VITAL 37 S BL (mirror reflection of BP version). Picture 7. Dimensions of DEFRO HOME VITAL 51 S U.
  • Page 10: Equipment

    Ø150 Ø150 Picture 10. Dimensions of DEFRO HOME VITAL 51 S BL and DEFRO Picture 11. Dimensions of DEFRO HOME VITAL 51 S C. HOME VITAL 51 BP (mirror reflection). 4.3. EQUIPMENT 6. SYSTEM The gas-fired heater is delivered on a pallet, foil-wrapped and are fully assembled.
  • Page 11: Connection To The Concentric Flue System

    Heater connection to the gas system should be in Installation of elbow 90⁰ results in reduction of total compliance with the applicable regulations. allowable length of the pipe by 2 meters. Installation of elbow 45⁰ results in reduction of total Shut off the gas inflow using main valve before allowable length of the pipe by 1 meter.
  • Page 12: Vertical Outlet Of Concentric Pipe - Type C31

    Mertik is the only one intended for mm, its maximum length should not exceed 6 m. installation in the DEFRO HOME VITAL heater. System can be Chimney section should not be lower than 150mm x 150mm. installed only in the brand-new fireplace.
  • Page 13: Adjustment

    spark igniter make possible corrections to ensure that pressure values for the given GV60 valve palnik kontrolny type of fuel corresponds to table 1 for both rated loads (minimum and and receiver box maximum). control burner unit 6.6.1. ADJUSTMENT OF FLAME IN THE CONTROL BURNER The control flame is factory set to the maximum height.
  • Page 14: Final Operations

    If the absolute value between the measured content of oxygen in flue gas and the value given in the table does not exceed 0.3% then it may be assumed that the flow damper setting is correct. Tighten the screw to lock the flue gas flow damper position. Gas type G2.350 Model: DEFRO HOME VITAL 37 11.6 12.8 13.8 DEFRO HOME VITAL 51 12.9 11.9...
  • Page 15: Conversion To The Other Gas

    Exhaust Screw the bolt in to the burner injector, grille should be located in hood. For DEFRO HOME VITAL the size of Perform adjustment acc. to the instruction in 6.8 choosing...
  • Page 16: Operation

    1 - parental lock, 2 - time, 3 - signal indicator, 4 - battery condition, 5 - temperature, 6 - timer, 7 - programme mode, 8 - economy mode, 9 - User controls operation of the DEFRO HOME VITAL heater via the B6R-H8TV4PBD remote control equipped with 8 buttons. To allow additional functions, 10 - temperature unit.
  • Page 17: Time Settings

    7.6.2. TIME SETTINGS be heard and an icon confirming the ignition will be flashing on the display. Release the buttons. The gas will flow to the primary burner after confirmation of ignition. Remote control automatically switches to manual control mode. 7.7.2.
  • Page 18: Timer

    Increase to maximum flame height takes place after double Programmed mode is one of two programs set, which specify when the heater should operate and what click of button, what is confirmed with HI message. temperature should be maintained. 7.7.6. TIMER Timer operates in Manual, Thermostatic and Eco(nomy) mode.
  • Page 19: Program Mode

    Press the buttons. Mode ALL Press the buttons causing switch to the other Configuration of program switch on time no. 1: modes Icon and symbols 1, ON will be displayed, message ALL will be shown for a while and hours field will flash. 7.7.9.
  • Page 20: Power Supply And Battery Replacement

    fireplace operates continuously without supervision for five (5) 7.9.1. FIRING UP successive days. Open gas supply valve. If the ON/OFF switch is installed (3 on picture 24) then set it 7.8. POWER SUPPLY AND BATTERY REPLACEMENT to ON position (press symbol I) Turn the control knob of the main burner clockwise to the If you hear the signal indicating that the batteries are max.
  • Page 21: Error Codes

    7.9.4. ERROR CODES Code Symptom Possible causes 5-second audible signal from the receiver No contact of microswitch with a cam on drive knob. Contact service centre Flame does not respond to remote control, no Incorrect connections of drive cables. ignition. Reversed polarity or fault of the microswitch.
  • Page 22 Code Symptom Possible causes Remote control shutdowns after a predefined time. Remote control shutdowns if the drive of the primary valve has not been activated after a predefined time. Flame does not respond to change of settings. Failure of receiver or WiFi module. Contact service centre.
  • Page 23: Decorative Items

    The combustion chamber can be additionally equipped with decoration items supplied by DEFRO. The customer shall be liable for use of components from the other manufacturers and resulting damages shall not be a base for any claims towards the manufacturer of DEFRO HOME VITAL heater.
  • Page 24: Assembly Of Ceramic Chunks

    8.2. ASSEMBLY OF CERAMIC CHUNKS View of combustion chamber corners burner before installation of chunks. gas gaps Lay item no. 1 as presented rear wall both photos. component should remain stable at the centre of the ignition burner and parallel to the rear wall.
  • Page 25 Lay item no. 2 in the right corner of the primary burner, as presented on both photos. Chunk should be stable due to incisions adapted to the burner. distance between the holes in the burner and the edge of the chunk should be approx.
  • Page 26 Lay item no. 3 in the left corner of the primary burner acc. to the incision and photos. Similarly, as for chunk no. 2, the distance between the holes in the burner and the edge of the chunk should be approx. 5 left corner of the burner the edge of the ceramic log...
  • Page 27 5. Lay chunk no. 4 as presented on the photos. The chunk should not cover burner openings and should be supported in half-way on chunk no. 1. gas holes...
  • Page 28 left corner of the burner gas holes...
  • Page 29 Lay item no. 5 as presented on photos. The chunk should be stable and should not cover gas openings in the floor. right corner of the burner gas gaps...
  • Page 30 Set the chunk no. 6 as the last one; it should be laid on chunk supported on chunk no. 4 and right corner of the burner.
  • Page 31 right corner of the burner...
  • Page 32: Laying Of Decoration Imitating The Stones

    8.3. LAYING OF DECORATION IMITATING THE STONES Items made of stone should be laid on the floor of the combustion chamber so as to avoid covering of gas openings.
  • Page 33: Maintenance And Service

    9. MAINTENANCE AND SERVICE To ensure correct operation of the equipment and that it does not pose any threats it should be cleaned on an ongoing basis and undergo inspections and maintenance by the authorized company or service. Periodic inspection of the equipment should be carried out only by qualified manufacturer’s service.
  • Page 34: Periodic Maintenance Inspection

    10.2. FLUE GAS ESCAPE Flue gas escape is another possible hazard to the life. If you notice damage to the flue system or presence of flue gas odour: Disconnect the device supply Open doors and windows Warn all residents and leave the building, Prevent access of members of the public into the building, Notify the authorized fitter company, Order removal of defects.
  • Page 35: Product Warranty Terms And Conditions

    The other elements of a stove have been made of materials neutral all damages resulting from incorrect transport from for the environment and are subject to standard waste disposal, mostly distributor to the customer, incorrect installation of the as steel scrap. After worn out of the stove parts connected with screws equipment, incorrectly made system, failure to keep should be disassembled by unscrewing and welded parts must be cut.
  • Page 36: Warranty Conditions "48H Service

    17) The Guarantor does not accept liability for inappropriate choice of purchaser exercises his powers resulting from the warranty, the product with respect to heated area (e.g. device of too low or too period for execution of powers resulting from the warranty will be high power with respect to requirements).
  • Page 37: Warranty Card

    WARRANTY CARD Confirmation of equipment's quality and completeness In accordance with the conditions stated herein, warranty for a gas-fired heater has been issued DEFRO HOME VITAL type ..operated in accordance with the operating manual. Equipment manufacturing number* ......................Equipment power ......................
  • Page 38: Carried Out Warranty Repairs And Maintenance

    15. CARRIED OUT WARRANTY REPAIRS AND MAINTENANCE. fault description, repaired element, Stamp and signature date comments description of repairs of Service...
  • Page 39: Warranty Card /Copy To Send Back

    WARRANTY CARD Confirmation of equipment's quality and completeness In accordance with the conditions stated herein, warranty for a gas-fired heater has been issued DEFRO HOME VITAL type ..operated in accordance with the operating manual. Equipment manufacturing number* ......................Equipment power ......................
  • Page 41: Complaint Form

    17. COMPLAINT FORM COMPLAINT FORM made on ............in connection with complaint no......SUBJECT OF COMPLAINT EQUIPMENT TYPE: ........... Equipment manufacturing date: ..........Equipment serial no.: ........... Equipment purchase date: ..........CLAIMANT Name and surname: ................................Detailed address: ................................................................
  • Page 43: Complaint Form

    18. COMPLAINT FORM COMPLAINT FORM made on............in connection with complaint no... SUBJECT OF COMPLAINT EQUIPMENT TYPE: ........... Equipment manufacturing date: ..........Equipment serial no.: ........... Equipment purchase date: ..........CLAIMANT Name and surname: ................................Detailed address: ................................................................ Phone number ................................
  • Page 45: Complaint Form

    19. COMPLAINT FORM COMPLAINT FORM made on ............in connection with complaint no......SUBJECT OF COMPLAINT EQUIPMENT TYPE: ........... Equipment manufacturing date: ..........Equipment serial no.: ........... Equipment purchase date: ..........CLAIMANT Name and surname: ................................Detailed address: ................................................................
  • Page 47: Register Of Inspections Of Smoke Ducts

    20. REGISTER OF INSPECTIONS OF SMOKE DUCTS date stamp and signature of chimneysweep date stamp and signature of chimneysweep...
  • Page 48 DEFRO Spółka z ograniczoną odpowiedzialnością Spółka komandytowa 00-403 Warszawa ul. Solec 24/253 Manufacturing plant 26-067 Strawczyn Ruda Strawczyńska 103A Model: DEFRO HOME VITAL Indirect heating function Direct thermal power 6.0 kW Indirect thermal power Fuel Fuel type G20, G27, G2.350...
  • Page 49 Contact data: DEFRO Spółka z ograniczoną odpowiedzialnością Spółka komandytowa 00-403 Warszawa ul. Solec 24/253 Manufacturing plant 26-067 Strawczyn Ruda Strawczyńska 103A Model: DEFRO HOME VITAL Indirect heating function Direct thermal power 5.5 kW Indirect thermal power Fuel Fuel type 3P, 3B/P...
  • Page 52 service hotline call us: 509 702 720 509 577 900 DEFRO Spółka z ograniczoną odpowiedzialnością Spółka komandytowa 00-403 Warszawa, ul. Solec 24/253 Production plant: Ruda Strawczyńska 103 A 26-067 Strawczyn tel.: 41 303 80 85, biuro@defro.pl NIP 9591968493...

This manual is also suitable for:

Vital 51s

Table of Contents