Step #2
Check the Electrical Supply Requirements
This product must be installed in accordance with national, state and local
electric codes. The following table provides the correct voltage, amperage
and frequency that must be supplied to the cooktop.
SUMMIT
Model #
CR2110/
WH
CR2220/
WH
The supply must be from an individual grounded circuit that is protected by
a circuit breaker and rated per the specifications for the various models as
shown in the table above.
WARNING: INSTALLATIONS MUST COMPLY WITH ALL LOCAL,
STATE AND NATIONAL ELECTRICAL CODES.
Failure to comply with the applicable codes may result in fire,
property damage, personal injury or death.
If the electric power supply does not meet the product
specifications, consult with a licensed electrician before
proceeding with installation.
Maximum
Connected
Power Supply
Load
2400 Watts
AC/25A/60Hz
2400 Watts
AC/10A/60Hz
6
Required
Minimum
Wire Size
Input
120V
#12 AWG
220V
#16 AWG