Page 1
Owner’s Manual Water Pump WP-80 NOTE Before using this equipment, ensure that the operator has read and fully understands all instructions in this manual.
Page 2
EC DECLARATION OF CONFORMITY / DECLARATION CE DE CONFORMITE / DECLARACIÓN DE CONFORMIDAD CE / DECLARAÇÃO CE DE CONFORMIDADE Nous soussignés, Uni-corp Europe, ZAC des Petits Carreaux 12 rue des Coquelicots 94380 Bonneuil Sur Marne, certifions que si le produit décrit dans ce certificat est acheté...
SAFETY ALERT & HAZARD SYMBOLS SAFETY ALERT SYMBOLS The following safety alert symbols will inform you about potential hazards that could injure you or others. They represent the level of exposure to the operator, and are preceded by one of three words: DANGER, WARNING, or CAUTION. DANGER: You WILL be KILLED or SERIOUSLY injured if you DO NOT follow directions.
Page 4
NEVER operate equipment with covers, or guards removed. Keep fingers, hands, hair and clothing away from all moving parts to prevent injury. Accidental Starting ALWAYS place the engine ON/OFF switch in the “OFF” position when the equipment is not in use. Over Speed Conditions NEVER tamper with the factory settings of the engine governor or settings.
Page 5
CAUTION: IMPROPER maintenance or use can be hazardous. READ and FULLY UNDERSTAND this section before you perform any maintenance, service or repairs. This equipment is to be used for its intended application only. • This equipment must be operated only by well-trained personnel. •...
Page 6
Spilt fuel must be made safe immediately, using sand. If fuel is spilt on your clothes, • change them. Store fuel in an approved, purpose made container away from heat and ignition • source. PPE (Personal Protective Equipment) Suitable PPE must be worn when using this equipment i.e. Safety Goggles, Gloves, Ear Defenders, Dust Mask and Steel Toe capped footwear (with anti-slip soles for added protection).
SPECIFICATION & TECHNICAL DATA Model P-80 Inlet and Outlet Diameter 3.0" Flow Capacity(L/Min) 1000 Suction Head(Meter) Delivery(Meter) Pump Set Package Dimension(mm) 530X390X465 Gross Weight of Pump Set(KG) 27.5 Engine(HP) PUMP CURVE 3' water pump 1000 1200 Flow (L/min) OPERATION PUMP PLACEMENT For best pump performance, place the pump close the water level \and use hoses that no longer...
SUCTION HOSE INSTALLATION Use the commercially available hose and hose connector with the hose clamp provided with the pump. Use a hose clamp to securely fasten the connector to suction hose in order to prevent the air leakage and loss of the suction. Verify that the hose connector sealing washer is in good condition.
Page 9
satisfactorily. Warning: Operating the pump dry will damage the pump seal. If the pump has been operated dry, stop the engine immediately, and allow the pump to cool before priming. TYPE OF WATER Pumps are capable of pumping septic tank effluent, sink wastes, small amounts of dirt or sand, drainage or polluted water and some industrial wastes.
6. Pull the starter grip lightly until resistance is felt, then pull it briskly 7. When engine running, moved the choke level to CLOSE position. SETTING ENGINE SPEED After starting the engine, move the throttle level to FAST position for self-priming, and check pump output.