Download Print this page

Advertisement

CAN
OK
?
!
!
%
%
CANH
CANH
CANL
CANL
+
+
Ref K6956000
CANH
CANH
CANL
CANL
DA
DATA
DATA
DA
!
xxo
xxo
test
test
For complete inspection and diagnosis of CAN High Speed multiplex circuits
OPERATOR'S MANUAL

Advertisement

loading
Need help?

Need help?

Do you have a question about the 714 PC and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for mecalac 714 PC

  • Page 1 OPERATOR’S MANUAL CANH CANH CANL CANL Ref K6956000 CANH CANH CANL CANL DATA DATA test test For complete inspection and diagnosis of CAN High Speed multiplex circuits...
  • Page 2 714 PC & 714 PW STATEMENT AND PRECAUTIONS TO BE READ BEFORE USING THE R CVX200 MUXMETRE To use the CVX200 in complete safety. To prevent any damage to the CVX200. • Operate the CVX299 only in accordance with the instructions in this manual, so as to preserve its integrated protection.
  • Page 3: Table Of Contents

    Table of Contents Page Contents of the KIT ..............4 Tester connection................ 5 Diagnostic procedure..............7 Static mode ................8 Dynamic mode................9 Identification of calculators present .......... 10 Interpretation of the indicator lights on the TX12 ...... 11...
  • Page 4: Contents Of The Kit

    714 PC & 714 PW Contents of the KIT CANH CANH CANL CANL Ref K6956000 CANH CANH CANL CANL DATA DATA test test A - Kit Part No. K6956000 B - Controller C - Tester TX12 D - Interface cable Part No. 6956000...
  • Page 5: Tester Connection

    714 PC & 714 PW Connecting the tester Kit K6956000 1 - Connect the tester power supply clamps to the vehicle’s battery terminals.(24V) 2 - Connect the interface cable to the diagnostic soc- ket on the vehicle (1 fig 1) Fig.
  • Page 6 714 PC & 714 PW CANH CANH CANL CANL Ref K6956000 CANH CANH CANL CANL DATA DATA test test Fig. 1 Tester...
  • Page 7: Diagnostic Procedure

    714 PC & 714 PW Diagnostic procedure Diagnosis This indicator lamp comes on if the tester is in static test mode (no voltage) This indicator lamp comes on if the tester is in dynamic test mode (voltage present) No communication (the wires 15 fig 1 and 16 fig 1 are not connected to a bus)
  • Page 8: Static Mode

    714 PC & 714 PW Static mode Purpose of test: check correct functioning of the CAN network CANH CANH CANL CANL Machine not switched on 1 - Put the device in static test mode by pressing successi- vely on the button (1 fig 1) until the indicator lamp (2 fig 1) lights up.
  • Page 9: Dynamic Mode

    714 PC & 714 PW Dynamic mode Machine switched on. 1 - Put the tester in dynamic test mode by pressing repea- tedly on the button (1 fig 1) until the indicator lamp (2 fig 1) lights up. CANH CANH...
  • Page 10: Identification Of Calculators Present

    714 PC & 714 PW Identification of calculators present CVX200 CVX200 CVX200 MECALAC MECALAC MECALAC Sn 1001 Sn 1001 Sn 1001 Note: This is found using the indicator lamps located on the back of the device MUXMETRE CVX200 (example 1 fig1).
  • Page 11: Interpretation Of The Indicator Lights On The Tx12

    714 PC & 714 PW Interpretation of the indicator lights on the TX12 TX 12 tester indicator lamps Interpretation of LED’s GREEN The measurement is connected to the battery earth The measurement is connected to the battery positive GREEN and red...
  • Page 12 GROUPE MECALAC MECALAC S.A.S. - Parc des Glaisins - 2, av. du Pré de Challes F-74940 Annecy-le-Vieux - France Tel: +33 (0)4 50 64 01 63 - Fax : +33 (0)4 50 64 02 79 www.mecalac.com...