1. Pack contents ......................................................................................................................... 2
2. Technical specifications ......................................................................................................... 3
3. Description ............................................................................................................................. 3
3.1. The principles of electrolysis ...................................................................................... 3
3.2. Presentation of the Limpido XC2 ............................................................................... 4
3.3. Production heat regulation (AUTO mode) ................................................................... 4
4. Installation ............................................................................................................................. 6
4.1. Hydraulic installation .................................................................................................. 6
4.2. Connection to electricity ............................................................................................. 8
5. Start up ................................................................................................................................ 11
5.1. Stabiliser ................................................................................................................... 11
5.2. Salt level check ......................................................................................................... 11
5.3. TAS / TH check ....................................................................................................... 12
5.4. pH checks ................................................................................................................. 12
6. Operation ............................................................................................................................. 13
6.1. Powering on .............................................................................................................. 13
6.2. Control interface ....................................................................................................... 13
6.3. Use ............................................................................................................................ 14
6.4. Low temperature ....................................................................................................... 20
6.5. Automatic cover ........................................................................................................ 20
6.6. Supervisor menu ....................................................................................................... 21
7. Maintenance ......................................................................................................................... 23
7.1. Adding salt ................................................................................................................ 23
7.2. Wintering .................................................................................................................. 23
7.3. Cell cleaning ............................................................................................................. 23
A. Menu synopsis ................................................................................................................... 25
B. Declaration of conformity ................................................................................................. 26
Read these instructions carefully before installing, commissioning and using
this product
MPNT0001 v4.0 (03/08/2015)
Technicalinst. guide
Limpido XC2
Réf : PF10I040 / PF10I033 / PF10I031
Smart electrolysis

Advertisement

Table of Contents
loading

Summary of Contents for ccei Limpido XC2

  • Page 1: Table Of Contents

    2. Technical specifications ......................3 3. Description ..........................3 3.1. The principles of electrolysis ..................3 3.2. Presentation of the Limpido XC2 ................4 3.3. Production heat regulation (AUTO mode) ..............4 4. Installation ..........................6 4.1. Hydraulic installation ....................6 4.2.
  • Page 2: Pack Contents

    Limpido XC2 v4.0 1. Pack contents • 1 electrolysis box Limpido XC2 • 1 electrolysis cell with built-in temperature sensor + 1 set of 2 union connections for 50mm diameter tubes • 1 flow detector fitted with a connector with a Ø50mm ¾" fixing collar + M/M ¾" nipple •...
  • Page 3: Technical Specifications

    Technicalinst. guide Limpido XC2 v4.0 2. Technical specifications Power supply voltage 230V~ AC 50/60Hz PF10I040 PF10I033 120W Power consumption PF10I031 150W Box: 290 x 350 x 150mm Dimensions: Cell: 312 x 100 x 120mm Packing box: 575 x 400 x 170mm Weight Box: 1.04 kg / Cell: 1.35 kg...
  • Page 4: Presentation Of The Limpido Xc2

    3. Phase 3, reverse mode production (negative) 4. Phase 4, standby At the end of the filtering period, the Limpido XC2 stops producing and restarts it exactly where it left off when filtering restarts. The main benefit of this choice of operating mode is to always guarantee (even if there is a power failure) that normal and reverse production times are strictly identical and, as a result, guarantee the best cell descaling possible (giving quality production and long equipment service life).
  • Page 5 Technicalinst. guide Limpido XC2 v4.0 The calculated production time is (in hours): (Pool temperature - Minimum temperature*) + 1. *The minimum temperature (15°C by default), can be configured. The calculated production time can therefore be influenced. There will be no production below this minimum temperature.
  • Page 6: Installation

    (installed upstream of the cell but on the same section of piping) and the earthing device (D). The cell (C), which is the essential part of the Limpido XC2, must be handled with care. It is fitted with solid titanium electrode plates treated with ruthenium oxide and is specially designed for a maximum service life and to limit maintenance operations.
  • Page 7 4.1.2. Water flow detector The Limpido XC2 is shipped with a flow detector. The flow detector is built into the cell delivered with the Limpido XC2.It prevents the electrolysis unit from running when there is no flow, or during a backwash.
  • Page 8: Connection To Electricity

    • either at 3.50 m from the pool edge. This distance takes into account the dis- tance around obstacles. If the Limpido XC2 box is installed behind a wall, the distance will include the length of the path taken to move around the wall to reach the box.
  • Page 9 Technicalinst. guide Limpido XC2 v4.0 4.2.1. Power supply, cell, flow detector The box is shipped with a power supply cable that can be connected to the mains in the technical room using a standard plug and socket (230V / 50 Hz). This socket must be protected by a 30mA ground fault circuit breaker in compliance with the NF C15-100 standard.
  • Page 10 Most covers are fitted with a travel switch to which the Limpido XC2 can be connected to adjust its production. This contact must be open when the cover is open, and closed when the cover is over the pool.
  • Page 11: Start Up

    When the salt level is not appropriate, the Limpido XC2 stops production if the salt level is too high or too low. If one of these faults occurs, first check that the cell is properly connected to the control box and that it is in working condition.
  • Page 12: Tas / Th Check

    Technicalinst. guide Limpido XC2 v4.0 At 35°C the maximum salt level is therefore changed from 5g/l to 3.9g/l. 5.3. TAS / TH check It is recommended when installing to ask a specialist to test the pool water's TAS (Total Alkaline strength) and/or TH (Total Hardness).
  • Page 13: Operation

    Technicalinst. guide Limpido XC2 v4.0 6. Operation 6.1. Powering on There is a switch on the control box to power on the electrolysis device. When the device is powered on, the switch lights. 6.2. Control interface The interface has a multi-function liquid crystal display with a 16 character line, and 4 keys;...
  • Page 14: Use

    The system is switched on using the luminous switch on the front. The screen displays the following home message: CCEI © 2015 v X.Y Where v X.Y is the version of the programme installed your Limpido XC2 display, followed by the control box model; LIMPIDO XC2 60/100/160 And finally the type of cell connected to the control box (example for a 60m3 model);...
  • Page 15 Technicalinst. guide Limpido XC2 v4.0 6.3.1. System status The default screen (screen saver) gives the status of the Limpido XC2; 25°C AUTO On the left is the water temperature, and on the right the configured electrolysis mode (see ELEC- TROLYSIS menu).
  • Page 16 Technicalinst. guide Limpido XC2 v4.0 Symbol Meaning Temperature low. If the selected mode is "PROG" or "AUTO", as the current temperature is less than the minimum temperature (configurable - see Min tem- perature), production is halted (wintering). Risk of freezing. This is for information (the system operation is not changed).
  • Page 17 Limpido XC2 v4.0 6.3.2. Messages Alternating with the status screen (screen saver) described above, the Limpido XC2 gives the user information to help prevent possible anomalies or to troubleshoot a possible fault. Messages are then displayed alternating with the device status:...
  • Page 18 Technicalinst. guide Limpido XC2 v4.0 6.3.3. Menus Using the keys, it is possible to scroll through the screens to access the following menus; Screen Function SETTING Used to access the device's general settings (see 6.3.4) CHLORINATOR Used to access the production settings (see 6.3.5)
  • Page 19 Technicalinst. guide Limpido XC2 v4.0 6.3.5. ELECTROLYSIS MENU This menu gives access to the production settings. Screen Function Prod. mode AUTO Used to selected the production mode (see below). Used to enter the TAS/TH value (configurable from 10 to 50°f) to adapt the polarity reversal time to the water alkalinity and hardness.
  • Page 20: Low Temperature

    SHOCK or ON mode. 6.5. Automatic cover If the Limpido XC2 is connected to an automatic cover, it detects when the cover is closed. If the cover is closed, • In PROG mode, production time is the time set on the "Cover cycle" menu.
  • Page 21: Supervisor Menu

    Technicalinst. guide Limpido XC2 v4.0 This feature is used to reduce the risk of large amounts of chlorine accumulating. 6.6. Supervisor menu 6.6.1. Access to the Supervisor menu Some of the functions on the device are reserved for use by installers or the persons in charge of maintaining the device.
  • Page 22 Supervisor mode can be exited by turning the device off and then back on again after about thirty seconds, using the ON/OFF button. 6.6.5. Reset to zero It may be necessary to reset the Limpido XC2. This returns all the settings to their default factory value. Your device will need to be reconfigured .
  • Page 23: Maintenance

    If a cover is used, the chlorine is protected from UVs and the chlorine needs drop. In Automatic mode, when the cover contact is connected, the Limpido XC2 reduces production automatically. To let the Limpido XC2 run in cold water (less than 18°C), it may be necessary to increase the salt level to 5g/l.
  • Page 24 Technicalinst. guide Limpido XC2 v4.0 Never pour water into the acid! Always pour the acid into the water "Water into acid, stupid acid into water, much smarter! www.c- cei.fr...
  • Page 25: Menu Synopsis

    Technicalinst. guide Limpido XC2 v4.0 A. Menu synopsis LIMPIDO XC2 MENU 22°C AUTO SETTING Linguage English Reset all? Confirm? Option : No config enable config disabled Pool Vol.=__m3 Temp. Correction=-2°c CHLORINATOR Menu Prod.Modus OFF TH=10°F mini Temp=15°c SHOCK run: 8h Cover run: 1h Prog.run= 1h...
  • Page 26: Declaration Of Conformity

    Technicalinst. guide Limpido XC2 v4.0 B. Declaration of conformity Bleu Electrique SAS (FR47403521693) declares that product Limpi- do XC2 is compliant with the safety and electromagnetic compatibili- ty requirements of European directives 2006/95/CE and 2004/108/CE . Emmanuel Baret Marseille, on 03/08/2015 Distributor's stamp Date of sale: .