Summary of Contents for Vents HEI240
Page 1
Installation and Operation Manual HEI240 INSERT (VB00012 Model) Safety tested according to ULC S628, UL 1482 and UL 737 by an accredited laboratory. US Environmental Protection Agency phase II certified wood insert compliant with 2020 cord wood standard. < ≤...
Page 3
It is also highly recommended to register the warranty online at http://www.occanada.com/en/service-support/warranty/warranty-registration Registering the warranty will help to quickly find the information needed on the unit. Installation and Operation Manual - HEI240 Page 3...
This product can expose you to chemicals including carbon monoxide, which is known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to www.P65warnings.ca.gov/ Installation and Operation Manual - HEI240 Page 7...
25%. As measured per CSA B415.1-10 stack loss method. Optimum overall efficiency at a specific burn rate (LHV). This appliance is officially tested and certified by an independent agency. Carbon monoxide. Page 8 Installation and Operation Manual - HEI240...
CAN/CSA- Z240 MH standard. Tested and certified in compliance with CFR 40 part 60, subpart AAA, section 60.534(a)(1(ii) and draft ASTM WK47329-14 Installation and Operation Manual - HEI240 Page 9...
Dimensions Top View Side View - Minimum Insert Projection Front View Side View - Maximum Insert Projection Page 10 Installation and Operation Manual - HEI240...
Page 11
Door Opening Front View - Combustion Chamber Side View - Combustion Chamber Installation and Operation Manual - HEI240 Page 11...
5 min. Then, close the door with the primary air control open. Leave to burn with the primary air control open for approximately 10 minutes and then close the primary air control completely for the low burn rate and halfway for the medium burn rate. Page 12 Installation and Operation Manual - HEI240...
The space where the most time is spent will be warmest, while bedrooms and basement (if there is one) will stay cooler. In this way, less wood is burned than with other forms of heating. Installation and Operation Manual - HEI240 Page 13...
OF STARTING A FIRE IN AN AFFECTED WOOD; WOOD HEATER. • MANURE OR ANIMAL REMAINS; BURNING THESE MATERIALS MAY RESULT IN THE RELEASE OF TOXIC FUMES OR RENDER THE HEATER INEFFECTIVE AND CAUSE SMOKE. Page 14 Installation and Operation Manual - HEI240...
Do not burn compressed logs made of wax impregnated sawdust or logs with any chemical additives. Follow the manufacturer’s instructions and warnings. Installation and Operation Manual - HEI240 Page 15...
− Dry wood is much lighter in weight than wet wood, − The face of a fresh cut feels warm and dry; − The moisture content read by a moisture meter is between 15% to 20%. Page 16 Installation and Operation Manual - HEI240...
Installation»); • Install the faceplate (See «Appendix 2: Faceplate Installation»). The following step is optional : • Install the fresh air intake (See «Appendix 3: Optional Fresh Air Intake Kit Installation»). Blower Installation and Operation Manual - HEI240 Page 17...
Potential causes of smoke spillage are described in Section «10. The Venting System», page 35 of this manual. See «Appendix 4: Optional Fire Screen Installation», page 44 for installation instructions. Page 18 Installation and Operation Manual - HEI240...
It is possible to use ragged paper but it may not hold in place since it tends to roll while it is burning. The best is to wrap a sheet on itself, grab the ends of the roll and make a knot. Installation and Operation Manual - HEI240 Page 19...
This is especially true if the chimney is on the outside wall of the house. If the door must be opened while the fire is flaming, fully open air control for a few minutes then open the door slowly. Page 20 Installation and Operation Manual - HEI240...
No other waste should be placed in this container. NEVER STORE ASHES INDOORS OR IN A NON-METALLIC CONTAINER OR ON A WOODEN DECK. CENDRES ASHES Installation and Operation Manual - HEI240 Page 21...
Before reducing the air intake, the load will have to burn at full heat for long enough for charring the surface of the logs. The flame must be bright before letting the fire burn by itself. Page 22 Installation and Operation Manual - HEI240...
Page 23
East-west loads allow a limited amount of wood since too many logs could cause them to fall on the glass. East-west loads, placed in a compact way, take a long time before breaking down. They are excellent for low-intensity, long-lasting fires in relatively mild weather. Installation and Operation Manual - HEI240 Page 23...
The goal should be having a clear glass with no brown stains. If brown stains appear regularly on the glass, something about the fuel or the operating procedure needs to be changed. Page 24 Installation and Operation Manual - HEI240...
Page 25
Stick the end of the gasket to the middle of one edge, then press the edge of the glass down onto the gasket, taking care that it is perfectly centred on the gasket. Installation and Operation Manual - HEI240 Page 25...
Page 26
Remove the split pin by pulling and turning it using pliers. Turn the handle one counterclockwise turn to increase pressure. Reinstall the split pin with a small hammer. Removing the retaining pin Reinstalling the retaining pin Page 26 Installation and Operation Manual - HEI240...
Even if creosote forms slowly in the system, the chimney should be cleaned and inspected at least once each year. Installation and Operation Manual - HEI240 Page 27...
Page 28
Do not use the appliance again until the insert and its chimney have been inspected by a qualified chimney sweep or a fire department inspector. Page 28 Installation and Operation Manual - HEI240...
CSA C22.1 Canadian National Electrical Code are to be followed in the absence of local code requirements. In the USA, the ANSI NFPA 211 Standard for Chimneys, Fireplaces, Vents and Solid Fuel-Burning Appliances and the ANSI NFPA 70 National Electrical Code are to be followed in the absence of local code requirements.
(406 mm USA) and at least 18" (457 mm Canada) without an R value. If the hearth elevation is lower than 4" (102 mm), the non-combustible (B) floor protection in front of the insert should have an R value equal or greater than 1.00 and shall extend 22" (560 mm) in front of the unit. Installation and Operation Manual - HEI240 Page 31...
Page 32
R-value, must extend at least 16" (406 mm in USA) or 18" (457 mm in Canada) in front of the unit (B). Refer to «Additional Floor Protection - Raised Installation». Page 32 Installation and Operation Manual - HEI240...
Page 33
R value = Thickness/K = 1/0.75 = 1.33 Information as reported by manufacturers and other resources Horizontal still air can’t be «stack» to accumulate R-values; each layer must be separated with another non-combustible material. Installation and Operation Manual - HEI240 Page 33...
28 7/8" (733 mm) 15 3/4" (400 mm) If a fresh air intake is required, it is recommended to add at least 4" to the width of the minimum opening of the hearth. Page 34 Installation and Operation Manual - HEI240...
The long end of the brackets must be attached to the insert. Insert the chimney liner into the flue collar of the unit and secure the liner to the brackets with three self-tapping screws (not included). Securing the brackets Page 36 Installation and Operation Manual - HEI240...
Page 37
The long end of the brackets must be attached to the insert. Then, follow the instructions in the manual provided with the liner offset adapter kit. Securing the brackets Offset liner adaptor Installation and Operation Manual - HEI240 Page 37...
Even the finest insert will not work well when connected to this chimney. Chimney location in the house Page 38 Installation and Operation Manual - HEI240...
Check the outdoor air duct for soot deposits when the full system is cleaned and inspected at least once each year. Installation and Operation Manual - HEI240 Page 39...
Before installing the blower, open the door and install the ash lip by screwing it in place with 3 screws, located in the user manual kit. Push the blower into the clips located underneath the ash lip. Page 40 Installation and Operation Manual - HEI240...
Lay the panels on a flat and non abrasive surface. Align the top panel holes (L) with the left (N) and right (M) panels. Secure together using the four bolts (P) and nuts (O) provided. Installation and Operation Manual - HEI240 Page 41...
Page 42
(R). Then push towards the fireplace. Once the faceplate is in place, secure the assembly by tightening nuts (S) using a 7/16" (11 mm) open end wrench. Page 42 Installation and Operation Manual - HEI240...
(F) using the other pipe clamp. The outside wall termination must be installed outside of the home. he pipe must be HVAC type, insulated, and must comply with ULC S110 and/or UL 181, Class 0 or Class 1. Installation and Operation Manual - HEI240 Page 43...
Lift the fire screen upwards and push the bottom part towards the insert then let the fire screen rest on the bottom of the door opening. Warning: Never leave the insert unattended while in use with the fire screen. Page 44 Installation and Operation Manual - HEI240...
Install the baffle. Repeat steps 1 and 2 for the three other tubes. When necessary, remove the tubes using the above steps in reverse order. Page 46 Installation and Operation Manual - HEI240...
Page 47
Note that secondary air tubes (A) can be replaced without removing the baffle board (B) and that all tubes are identical. Installation and Operation Manual - HEI240 Page 47...
Remove faceplate (C) by pulling on it. Remove the blower assembly (D). Remove the three screws securing the pipe connector (A). Unscrew the bolts securing the insert to the floor on each side of the unit (E). Page 48 Installation and Operation Manual - HEI240...
APPENDIx 8: ExPLODED DIAGRAM AND PARTS LIST Installation and Operation Manual - HEI240 Page 49...
Page 50
METALLIC BLACK STOVE PAINT - 342 g (12oz) AEROSOL 30337 SQUARE HEAD SET SCREW 1/2-13 X 1-3/4" AC01298 5"Ø FRESH AIR INTAKE KIT OVAL PL53869 FACEPLATE EXTENSION 30187 STAINLESS WASHER ID 17/64" X OD 1/2" PL65579 AIR CONTROL DAMPER Page 50 Installation and Operation Manual - HEI240...
Page 51
POWER CORD 96" X 18-3 type SJT (50 pcs per carton) 44080 RHEOSTAT WITHOUT NUT (MODEL KBMS-13BV) 44087 RHEOSTAT NUT 44085 RHEOSTAT KNOB AC01315 RIGID FIRE SCREEN 30898 ROUND WOODEN BLACK HANDLE DULL BLACK FINISH Installation and Operation Manual - HEI240 Page 51...
VENTIS LIMITED LIFETIME WARRANTY The warranty of the manufacturer extends only to the original retail purchaser and is not transferable. This warranty covers brand new products only, which have not been altered, modi ed nor repaired since shipment from the factory. Proof of purchase (dated bill of sale), model name and serial number must be supplied when making any warranty claim to the VENTIS dealer.
Page 56
This document is available for free download on the Stove Builder International inc. manufacturer’s website. It is a copyrighted document. 250, rue de Copenhague, Resale is strictly prohibited. The manufacturer may update St-Augustin-de-Desmaures (Québec) Canada this document from time to time and cannot be responsible G3A 2H3 for problems, injuries, or damages arising out of the use 418-908-8002...