Advertisement

Quick Links

Combi Port E D
EN
Installation and operation manual
CD0000XXX
CD0000390

Advertisement

Table of Contents
loading

Summary of Contents for KaMo uponor Combi Port E D

  • Page 1 Combi Port E D Installation and operation manual CD0000XXX CD0000390...
  • Page 2: Table Of Contents

    Table of contents Differential pressure regulator ..........23 Hydraulic balancing on the manifold........23 Wiring diagram..............24 Copyright and disclaimer............. 3 Dimensional drawings............27 Performance curves for domestic water heat exchanger..28 Performance curves for heating heat exchanger....33 Preface................... 4 Safety instructions..............
  • Page 3: Copyright And Disclaimer

    1 Copyright and disclaimer Uponor has prepared this installation and operation manual and all the content included solely for information purposes. The contents of the manual (including graphics, logos, icons, text, and images) are copyrighted and protected by worldwide copyright laws and treaty provisions.
  • Page 4: Preface

    2 Preface This installation and operation manual describes how to install and • Installation must be performed by a competent person in operate the components of the system. accordance with local regulations. • It is prohibited to make changes or modifications not specified in The manual shows an example of a Combi Port E connection variant.
  • Page 5 Household users should contact either the retailer where they purchased this product, or their local government office, for details of where and how they can take this item for environmentally safe recycling. Business users should contact their supplier and check the terms and conditions of the purchase contract.
  • Page 6: System Description Combi Port E D

    3 System description Combi Port E D 3.1 Operating principle Combi Port E D-UFH Combi Port E D is available in two different versions: Combi Port E D-UFH, for domestic water and direct heating. This can be used in single or multi family houses. Combi Port E D-X, for domestic water and indirect heating (additional heat exchanger on the heating side).
  • Page 7: Accessories

    Combi Port E D-X The following accessories are optional. Their use completes the product portfolio. The application is described in more detail in the following chapters. Port Base and pipe connection set CD0000367 Port Base is a station prepared for connetion to the heat interface unit by using the available pipe connection set.
  • Page 8 Ball valve set Installation and configuration Wave Base Base PRO functions Pulse Pulse Installation wizard ✓ ✓ Offline configuration ✓ ✓ Over-the-air updates ✓ ✓ Third-party remote support ✓ ✓ Comfort function Wave Base Base PRO Pulse Pulse Mobile app ✓...
  • Page 9: Installation

    4 Installation 4.1 Installation example The insulation mounted in the unit is removed in the illustrations only to show all components and increase the understanding. The installation of Combi Port E D-X is performed in the same way. 4.3 Heat interface unit with UFH manifold Install the wall bracket Note...
  • Page 10 Install the heat interface unit Connect the primary supply pipes Note Install the pipes in accordance with planning documentation. Note Ensure the use of supplied seals when connecting the pipes! Note Ensure that pipe insulation and fixing is made in accordance with EnEV.
  • Page 11: Heat Interface Unit With Port Base

    Connect the underfloor heating and tap water Install the room temperature control pipes Note Note Visit the Uponor download centre for more information regarding the installation and configuration of Uponor Install the pipes in accordance with planning Smatrix and Uponor Base flexiboard. documentation.
  • Page 12 Connect the tap water and underfloor heating Install the circulation line (optional) pipes Note Install the pipes in accordance with planning documentation. Note Ensure the use of supplied seals when connecting the pipes! Note Ensure that pipe insulation and fixing is made in accordance with EnEV.
  • Page 13: Additional Installation

    5 Additional installation 5.1 Strainer The differential pressure controller secures for constant pressure difference in the system. The setting is made by turning the spindle. Caution! Lock the unit and relieve the pressure before any work with the strainer. 5.3 Combi Port E D-X Note To open the cold water/primary flow strainer, use internal Expansion vessel...
  • Page 14: Other Components/Devices

    controller. At this connection, a bridge must be installed by an 5.5 Filling, flushing and venting electrician. Note 5.4 Other components/devices Switch off the pump before filling and venting the system! Outdoor temperature sensor SI0000327 Item Description SI0000329 Outdoor temperature sensor Item Description The outdoor temperature sensor serves as an input signal and...
  • Page 15: Operation

    6 Operation 6.1 Hydraulic balancing on the 6.2 Constant pressure pump manifold control Warning! Note The pressure in the valves can cause personal injury. Please read the installation manual from the pump manufacturer. Caution! Never turn the valves counter clockwise more than five (5) turns.
  • Page 16: Combi Port E Mobile Application

    Changing the pump settings Combi Port E app Note It is recommended that the pump runs at constant pressure when used for underfloor heating. The factory setting of the pump is not set to constant pressure and must therefore be changed The pump (Grundfos UPM3) has to be set to the constant pressure modus (Δp-c) to enable an optimal operation of the underfloor heating system.
  • Page 17 C Hot water Item Description Connection status Settings Hot water Circulation Combi Port E Hot water Uponor Combi Port E Supplier Standby Hot water Back Heating Status Standby System Status 43.7°C 11.3°C A Connection status 43.7°C 11.3°C Hot water Cold water Hot water Cold water 0 l/min...
  • Page 18: Commissioning And Hand Over

    E Supplier DISPLAYED VALUES • Supply secondary • Return secondary • Outdoor temperature (optional) • Room temperature (optional) Combi Port E Supplier Uponor Combi Port E • External input (optional) Standby Supplier Back G System Status Standby Status 53.1°C 36.9°C 53.1°C 36.9°C Supply...
  • Page 19: Maintenance

    7 Maintenance 7.1 General information 7.2 Turning off heat interface unit Note Important information If droplets of water are detected, call a qualified service personnel. To ensure the correct and safe operation of the system, this information must be read and followed. Ball valves must be closed in the event of malfunctions.
  • Page 20: Troubleshooting

    8 Troubleshooting 8.1 Fault description Fault description Cause Solution Hot water function Hot water temperature too low or volatile Central heating Buffer temperature too low Buffer temperature must be 5-10 K above hot water setpoint Heating circuit pump type not supported The following pump type is supported: Grundfos UMP3 Setting for heating circuit pump is not correct...
  • Page 21: App Alarms

    Fault description Cause Solution Pump not connected Check the pump connection No hot water and no heating Ball valves/locking devices closed Open locking devices Controller is not working Check if the check valve is installed in the circulation line (when the circulation set is installed) Central heating circuit pump not working Check that the central heating circuit pump is working and correctly set...
  • Page 22: Technical Data

    9 Technical data 9.1 Technical specifications 9.2 Electrical connection controller Combi Port E D-UFH Value Electrical net connection, 230 V AC Medium Heating water according to VDI 2035 Operating temperature 5-85 °C (90 °C temporary) Contacts Description Marking Max. operating pressure 10 bar, heating (X1) Phase...
  • Page 23: Data Output

    Flow sensor input Description Value Address 1 ... 253 (for Modbus) Contacts Description Marking (X22) Impulse signal Cold water from riser (CW) (Flow sensor) 9.4 Differential pressure regulator ⊥ Earthing on site for I1 ― Supply for I1 ― (X21) Impulse signal Heating return (primary) (Flow sensor) ΔPv kPa...
  • Page 24: Wiring Diagram

    9.6 Wiring diagram Combi Port E D with Uponor Smatrix Wave Pulse T-166 T-168 T-165 T-163 T-169 L L’ PUMP BOILER Fuse < > T3.15A Power 24 V WD0000034 Combi Port E D Installation and operation manual...
  • Page 25 Description of wiring diagram Flow sensors Item Description Contact Description Colour cable Venting screw Heating return (primary) Blue Motor valve Cold water from riser (CW) Green Differential pressure regulator (optional) Backflow preventer (optional) Heat meter distance piece Heating supply pump Temperature sensors Strainer Combi Port E controller...
  • Page 26 Combi Port E D with single room thermostat WD0000035 Combi Port E D Installation and operation manual...
  • Page 27: Dimensional Drawings

    Description of wiring diagram 9.7 Dimensional drawings Item Description All dimensions are given in mm. Venting screw Motor valve Combi Port E D-UFH Differential pressure regulator Backflow preventer Heat meter distance piece Heating supply pump Strainer Combi Port E controller Plate heat exchanger Safety valve Flow sensor...
  • Page 28: Performance Curves For Domestic Water Heat Exchanger

    Port Base connection set 9.8 Performance curves for domestic water heat exchanger CD0000396 Item Description Domestic water heat exchanger Combi Port E D-UFH, Combi Port E D-X ― 24 plates Pressure losses Heating side (primary) ZD0000030 0.80 1500 0.70 Wall bracket 0.60 0.50 0.40...
  • Page 29 Domestic hot water side (secondary) Tapping capacity 35 K (10-45 °C) 1.00 0.90 0.80 50 °C 0.70 55 °C 0.60 60 °C 0.50 65 °C 70 °C 0.40 75 °C 80 °C 0.30 85 °C 0.20 0.10 0.00 10.0 12.0 14.0 16.0 18.0...
  • Page 30 Tapping capacity 40 K (10-50 °C) Tapping capacity 45 K (10-55 °C) 60 °C 55 °C 65 °C 70 °C 60 °C 65 °C 75 °C 70 °C 80 °C 75 °C 85 °C 80 °C 85 °C Item Description Item Description Return temperature °C...
  • Page 31 Tapping capacity 50 K (10-60 °C) Domestic hot water side (secondary) 1.00 65 °C 0.90 70 °C 0.80 0.70 75 °C 80 °C 0.60 85 °C 0.50 0.40 0.30 0.20 0.10 0.00 10.0 12.0 14.0 16.0 18.0 20.0 22.0 24.0 26.0 Item Description...
  • Page 32 Tapping capacity 35 K (10-45 °C) Tapping capacity 40 K (10-50 °C) 55 °C 50 °C 60 °C 55 °C 65 °C 60 °C 70 °C 65 °C 75 °C 70 °C 80 °C 75 °C 85 °C 80 °C 85 °C Item Description...
  • Page 33: Performance Curves For Heating Heat Exchanger

    Tapping capacity 45 K (10-55 °C) Tapping capacity 50 K (10-60 °C) 65 °C 60 °C 70 °C 65 °C 75 °C 70 °C 80 °C 75 °C 85 °C 80 °C 85 °C Item Description Item Description Return temperature °C Return temperature °C Tapping capacity in litres/minute (l/min) Tapping capacity in litres/minute (l/min)
  • Page 34 Combi Port E D-UFH, Combi Port E D-X Heating heat exchanger values ― 24 plates Primary heating supply 70 °C Pressure losses Primary Supply °C Return °C ΔT 70.0 41.0 29.0 29.6 70.0 41.0 29.0 59.3 0.70 70.0 41.0 29.0 118.6 70.0 41.5...
  • Page 35 Combi Port E D Installation and operation manual...
  • Page 36 KaMo GmbH Uponor GmbH Max-Planck-Straße 11 Industriestraße 56, D-89584 Ehingen, Germany D-97437 Hassfurt, Germany 1105741 v1_03_2020 Production: Uponor/ELO Uponor reserves the right to make changes, without prior notification, to the specification of incorporated components in line with its policy of continuous www.uponor.com...

Table of Contents