Download Print this page

Middleby CROWN GS-30 Installation & Operation Manual

Gas floor model braising pan with manual gearbox tilt

Advertisement

Quick Links

IMPORTANT FOR FUTURE REFERENCE
Please complete this information and retain this
manual for the life of the equipment:
Model #: ___________________________
Serial #: ___________________________
Date Purchased: ____________________
INSTALLATION & OPERATION
MANUAL
Gas Floor Model Braising Pan With Manual Gearbox Tilt
GS-30 GS-40 GS-40N GS-60
WARNING
Improper installation, adjustment, alteration, service or maintenance can cause property damage, injury or death. Read
the installation, operating and maintenance instructions thoroughly before installing or servicing this equipment.
CROWN FOOD SERVICE EQUIPMENT
y
A Middleby Compan
70 Oakdale Road, Downsview (Toronto) Ontario, Canada, M3N 1V9
Telephone: 919-762-1000
www.crownsteamgroup.com
Printed in Canada
MANUAL 10152R4

Advertisement

loading
Need help?

Need help?

Do you have a question about the CROWN GS-30 and is the answer not in the manual?

Questions and answers

Summary of Contents for Middleby CROWN GS-30

  • Page 1 Improper installation, adjustment, alteration, service or maintenance can cause property damage, injury or death. Read the installation, operating and maintenance instructions thoroughly before installing or servicing this equipment. CROWN FOOD SERVICE EQUIPMENT A Middleby Compan 70 Oakdale Road, Downsview (Toronto) Ontario, Canada, M3N 1V9 Telephone: 919-762-1000 www.crownsteamgroup.com...
  • Page 2: Important Notes For Installation And Operation

    INSTALLATION AND OPERATION MANUAL, GAS FLOOR MODEL BRAISING PAN WITH MANUAL GEARBOX TILT, GS-30, GS-40, GS-40N, GS-60 IMPORTANT NOTES FOR INSTALLATION AND OPERATION It is recommended that this manual be read thoroughly and that all instructions be followed carefully. This manual should be retained for future reference. This is the safety alert symbol.
  • Page 3: Table Of Contents

    INSTALLATION AND OPERATION MANUAL, GAS FLOOR MODEL BRAISING PAN WITH MANUAL GEARBOX TILT, GS-30, GS-40, GS-40N, GS-60 TABLE OF CONTENTS DESCRIPTION PAGE Important Notes for Installation and Operation ........2 1.0 Service Connections .
  • Page 4: Service Connections

    INSTALLATION AND OPERATION MANUAL, GAS FLOOR MODEL BRAISING PAN WITH MANUAL GEARBOX TILT, GS-30, GS-40, GS-40N, GS-60 1.0 SERVICE CONNECTIONS MANUAL 10152R4 2021-08-19...
  • Page 5 INSTALLATION AND OPERATION MANUAL, GAS FLOOR MODEL BRAISING PAN WITH MANUAL GEARBOX TILT, GS-30, GS-40, GS-40N, GS-60 1.0 SERVICE CONNECTIONS (Continued) WITH OPTIONAL S-SDP-2 ASSEMBLY MANUAL 10152R4 2021-08-19...
  • Page 6 INSTALLATION AND OPERATION MANUAL, GAS FLOOR MODEL BRAISING PAN WITH MANUAL GEARBOX TILT, GS-30, GS-40, GS-40N, GS-60 1.0 SERVICE CONNECTIONS (Continued) MANUAL 10152R4 2021-08-19...
  • Page 7 INSTALLATION AND OPERATION MANUAL, GAS FLOOR MODEL BRAISING PAN WITH MANUAL GEARBOX TILT, GS-30, GS-40, GS-40N, GS-60 1.0 SERVICE CONNECTIONS (Continued) MANUAL 10152R4 2021-08-19...
  • Page 8: Installation Instructions

    INSTALLATION AND OPERATION MANUAL, GAS FLOOR MODEL BRAISING PAN WITH MANUAL GEARBOX TILT, GS-30, GS-40, GS-40N, GS-60 2.0 INSTALLATION INSTRUCTIONS UNPACKING Immediately after unpacking, check for possible shipping damage. If the tilting braising pan is found to be damaged, save the packaging material and contact the carrier within 15 days of delivery.
  • Page 9 INSTALLATION AND OPERATION MANUAL, GAS FLOOR MODEL BRAISING PAN WITH MANUAL GEARBOX TILT, GS-30, GS-40, GS-40N, GS-60 2.0 INSTALLATION INSTRUCTIONS (Continued) INSTALLATION CODES AND STANDARDS (Continued) The appliance must be isolated from the gas supply piping system by closing its individual manual shut off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than ½...
  • Page 10 INSTALLATION AND OPERATION MANUAL, GAS FLOOR MODEL BRAISING PAN WITH MANUAL GEARBOX TILT, GS-30, GS-40, GS-40N, GS-60 2.0 INSTALLATION INSTRUCTIONS (Continued) 6. Seal bolts and flanged feet with Silastic or equivalent compound. WARNING: Do not connect the appliance to the electrical supply until after the gas connection has been made.
  • Page 11: Operation Instructions

    INSTALLATION AND OPERATION MANUAL, GAS FLOOR MODEL BRAISING PAN WITH MANUAL GEARBOX TILT, GS-30, GS-40, GS-40N, GS-60 3.0 OPERATION INSTRUCTIONS CAUTION: The appliance and its parts are hot. Use care when operating, cleaning and servicing the appliance. BEFORE FIRST USE Using a non-corrosive, grease-dissolving commercial cleaner, clean the protective metal oils from all surface parts and the interior of the tilting braising pan.
  • Page 12 INSTALLATION AND OPERATION MANUAL, GAS FLOOR MODEL BRAISING PAN WITH MANUAL GEARBOX TILT, GS-30, GS-40, GS-40N, GS-60 3.0 OPERATION INSTRUCTIONS (Continued) START-UP PROCEDURE 1. Open manual gas shutoff valve. 2. Ensure that the braising pan is in the DOWN position. 3.
  • Page 13 INSTALLATION AND OPERATION MANUAL, GAS FLOOR MODEL BRAISING PAN WITH MANUAL GEARBOX TILT, GS-30, GS-40, GS-40N, GS-60 3.0 OPERATION INSTRUCTIONS (Continued) FIGURE 2 MANUAL 10152R4 2021-08-19...
  • Page 14: Periodic Maintenance

    INSTALLATION AND OPERATION MANUAL, GAS FLOOR MODEL BRAISING PAN WITH MANUAL GEARBOX TILT, GS-30, GS-40, GS-40N, GS-60 4.0 PERIODIC MAINTENANCE WARNING: Disconnect the power supply to the appliance before cleaning or servicing. CLEANING After each use, allow the tilting braising pan to cool and clean it. Keep exposed cleanable areas of the tilting braising pan clean at all times.
  • Page 15 INSTALLATION AND OPERATION MANUAL, GAS FLOOR MODEL BRAISING PAN WITH MANUAL GEARBOX TILT, GS-30, GS-40, GS-40N, GS-60 4.0 PERIODIC MAINTENANCE (Continued) CAUTION: The appliance and its parts are hot. Use care when operating, cleaning and servicing the appliance. ADJUSTMENTS All tilting braising pans are adjusted at the factory. At least twice a year, have an authorized service person clean and adjust the tilting braising pan for maximum performance.
  • Page 16: Cooking Guidelines

    INSTALLATION AND OPERATION MANUAL, GAS FLOOR MODEL BRAISING PAN WITH MANUAL GEARBOX TILT, GS-30, GS-40, GS-40N, GS-60 5.0 COOKING GUIDELINES The guidelines given below are suggested quantities, temperature settings, and estimated numbers of orders per load and per hour. When two temperatures are given, the first is to start the product, and the second to finish the product.
  • Page 17 INSTALLATION AND OPERATION MANUAL, GAS FLOOR MODEL BRAISING PAN WITH MANUAL GEARBOX TILT, GS-30, GS-40, GS-40N, GS-60 BATCHES GS-30 GS-40 PORTION TEMP. PER LOAD PER LOAD ITEM SIZE ( F) HOUR QTY. PORTIONS QTY . PORTIONS FISH Clams 1 pint 10 quarts 15 quarts Fish Cakes...
  • Page 18 INSTALLATION AND OPERATION MANUAL, GAS FLOOR MODEL BRAISING PAN WITH MANUAL GEARBOX TILT, GS-30, GS-40, GS-40N, GS-60 BATCHES GS-30 GS-40 PORTION TEMP. PER LOAD PER LOAD ITEM SIZE ( F) HOUR QTY. PORTIONS QTY . PORTIONS Potatoes 3 oz 40 lb 60 lb Spinach 4 oz...
  • Page 19 INSTALLATION AND OPERATION MANUAL, GAS FLOOR MODEL BRAISING PAN WITH MANUAL GEARBOX TILT, GS-30, GS-40, GS-40N, GS-60 BATCHES GS-30 GS-40 PORTION TEMP. PER LOAD PER LOAD ITEM SIZE ( F) HOUR QTY. PORTIONS QTY . PORTIONS Beef Stew 8 oz 18 gal.
  • Page 20 INSTALLATION AND OPERATION MANUAL, GAS FLOOR MODEL BRAISING PAN WITH MANUAL GEARBOX TILT, GS-30, GS-40, GS-40N, GS-60 BATCHES GS-30 GS-40 PORTION TEMP. PER LOAD PER LOAD ITEM SIZE ( F) HOUR QTY. PORTIONS QTY . PORTIONS MISCELLANEOUS Grilled Cheese Sandwich sandwich sandwiches sandwiches...
  • Page 21: Troubleshooting