Quick Links

Bulletin FFD/VS-02-2
INSTALLATION and
OPERATION MANUAL
Model FFD-3000VS
SCATTERGRAIN

Advertisement

Table of Contents
loading

Summary of Contents for Farm Fans SCATTERGRAIN FFD-3000VS

  • Page 1 Bulletin FFD/VS-02-2 INSTALLATION and OPERATION MANUAL Model FFD-3000VS SCATTERGRAIN...
  • Page 2: Warranty

    Copyright © 1997 by Farm Fans, a division of ffi Corporation. All rights reserved. No part of this publication may be used or reproduced in any form or by any means without prior permission. Failure to comply with this notice is a violation of United States copyright laws.
  • Page 3 DESCRIPTION The standard hangers supplied with the unit will adjust to roof openings of 21 to 30 inches. For larger openings up to 40 inches, order the optional FFD-120X extension The Model FFD-3000VS Scattergrain is a high perfor- bracket kit. mance, variable speed grain spreader, designed to pro- vide optimum spreading for a wide range of different For roof openings of 40"...
  • Page 4: Installation And Connection

    SCR CONTROL BOARD WARNING! POWER SWI TCH TERMI NAL STRI P I NDI CATOR LI GHT GROUND L UG SPEED CONTROL KNOB 8- AMP, 250V FUSES 220V MODELS FFD3.DS4 Fig. 2 - Control box parts FFD3.DS4 INSTALLATION AND CONNECTION 5- AMP, 600V FUSES 1.
  • Page 5 1. Blade Adjustment Information NOTE: The information within the previous headings describe the pre-adjustments required for extremes of SMALL BINS - 24' DIAMETER OR LESS - The blade bin sizes. For in-between sizes, start with intermediate extension should be removed for small diameter bins. adjustments, then vary settings slightly, if required.
  • Page 6 the control. The use of higher amperage fuses will void control warranty. If motor pinion requires removal for any reason, it must be properly installed and located, as shown in the parts illustration. POWER SUPPLY GREEN 440 VOLTS PRIMARY FUSES (5-AMP) H1 H2 H3 H4...
  • Page 7: Trouble Analysis Procedure

    TROUBLE ANALYSIS PROCEDURE WARNING: Turn off power at disconnect and lock it off before entering the bin to work on or near the Scattergrain. Stay clear of rotating blade when power is on! TROUBLE CHECKOUT PROCEDURE & INFORMATION Motor does not run; 1.
  • Page 8 TROUBLE CHECKOUT PROCEDURE & INFORMATION Motor stalls or runs at 1. LOW VOLTAGE - Check input voltage between terminals 1 and 2 on terminal strip in very low speed with Vari-speed control box; voltage should not be below 218 VAC; increase voltage to 230 speed control turned on VAC.
  • Page 9 FFD-3000VS SCATTERGRAIN PARTS Replacement parts can be obtained from the local Farm Any parts or equipment sent to the factory must be Fans dealer or by contacting Farm Fan at 5900 shipped freight prepaid and be accompanied with form Elmwood Ave., Indianapolis, IN 46203. Phone 317 787- RMF-03-5 fully completed.
  • Page 10 FFD-3000VS PARTS LIST ITEM PART NO. EARLY FF NO. DESCRIPTION .........QTY. 306-1168-5 A06-068 SCATTER PLATE BACK-UP .
  • Page 11 SCR CONTROL BOARD HOOK-UP SPEEDPOT LO (orange lead) SPEEDPOT WIPER (red lead) SPEEDPOT HI (white lead) + FIELD (+F) - ARMATURE / - FIELD (-A/-F) + ARMATURE (+A) VAC INPUT (AC) 220V MODEL S VAC INPUT (AC) 14 27 12 13 28 29 11 17 FFD1.DS4...
  • Page 12 SPEEDPOT LO (orange lead) SPEEDPOT WIPER (red lead) SCR CONTROL SPEEDPOT HI (white lead) BOARD + FIELD (+F) HOOK-UP - ARMATURE / - FIELD (-A/-F) + ARMATURE (+A) VAC INPUT (AC) VAC INPUT (AC) 440V MODEL S 13 14 SUPPLI ED WI TH I TEM 11 A - A VI EW...