IP Power Socket 6G10A v2
MANUAL

Advertisement

loading
Need help?

Need help?

Do you have a question about the 6G10A and is the answer not in the manual?

Questions and answers

Summary of Contents for Tinycontrol 6G10A

  • Page 1 IP Power Socket 6G10A v2 MANUAL...
  • Page 2 Power strip technical data - including above all permissible current rating and maximum permissible load located on the housing. Technical data can also be seen on the packa- ging or in the data sheet (available at: www.ledats.pl, www.tinycontrol.eu or www.wire- lesslan.pl).
  • Page 3: Technical Specifications

    IP Power Socket 6G10A v2 – LANLIS-010, LANLIS-015 IP Power Socket 6G10A v2 Power distribution unit in Rack 19” standard. Equipped with six independently managed outlets for 230V. Management available by embeded web server or SNMP protocol. Except ethernet socket ther is 1wire socket for temperature measurement.
  • Page 4: Control Panel

    IP Power Socket 6G10A v2 – LANLIS-010, LANLIS-015 Management by WWW. 1. Control Panel Reset time – for 0 normal outputs work (ON/OFF) , for time > 0 output after push button change state and return to state before Change outputs...
  • Page 5 IP Power Socket 6G10A v2 – LANLIS-010, LANLIS-015 2. Events Config Connection time slot Delay of set outputs Automatic application when starting terminal. after occur events, of the socket after starting Prevents inclusion all in seconds max 65535 terminal sockets at the same time.
  • Page 6 IP Power Socket 6G10A v2 – LANLIS-010, LANLIS-015 Functional Description Event Table With this change, you can flexibly define thresholds and intervals in which such slot is to be enabled / disabled. If you have the proper checks the condition of a number of sensors is to force the state to be the sockets that was last registered event.
  • Page 7 IP Power Socket 6G10A v2 – LANLIS-010, LANLIS-015 4. Scheduler Format: number output (from 0 to 5),day1,day2,day3,day4,day5,day6, xx:xx:xx(time) Week Day: Mo - Monday, Tu- Tuesday, We - Wednesday, Th - Thursday, Fi - Friday, Sa - Sa- turday, Su - Sunday, ## - all week day. Letter size is important.
  • Page 8: Network Configuration

    IP Power Socket 6G10A v2 – LANLIS-010, LANLIS-015 5. Network Configuration e-mail client set- tings parameter. After changing the settings in order to test the customer - should be save your settings - the „Save Config” button. The user name and password to access the module.
  • Page 9 IP Power Socket 6G10A v2 – LANLIS-010, LANLIS-015 NTP server settings. Time Interval - the interval in minutes between synchroni- zations. Fields community (password) for SNMP, must be the same in your queries in order to LK replied. TRAP Enable –...
  • Page 10 IP Power Socket 6G10A v2 – LANLIS-010, LANLIS-015 Reading XML data Enter the IP address and the page name eg 192.168.1.100/st0.xml The values of the sensors should be divided by 10 Control Panel: - Dynamic data - st0.xml - Static data - st2.xml Events Config: s.xml...
  • Page 11: Firmware Upgrade

    IP Power Socket 6G10A v2 – LANLIS-010, LANLIS-015 Firmware Upgrade In the event that there is a new version of the software or special version for application, it is possible to load such software to the device. This can be done remotely over the ne- twork using TFTP.
  • Page 12 IP Power Socket 6G10A v2 – LANLIS-010, LANLIS-015 NUMBERS OID for SNMP Soft_version .1.3.6.1.2.1.1.1.0 READWRITE ASCII_STRING SYS_OID .1.3.6.1.2.1.1.2.0 READONLY OID SYS_UP_TIME .1.3.6.1.2.1.1.3.0 READONLY TIME_TICKS. LAN_NAME .1.3.6.1.2.1.1.5.0 READWRITE ASCII_STRING. TRAP_RECEIVER_ID .1.3.6.1.4.1.17095.2.1.1.1.1 READWRITE BYTE. TRAP_RECEIVER_ENABLED .1.3.6.1.4.1.17095.2.1.1.2.1 READWRITE BYTE. TRAP_RECEIVER_IP .1.3.6.1.4.1.17095.2.1.1.3.1 READWRITE IP_ADDRESS.