loading
Need help?

Need help?

Do you have a question about the Micro One 230 and is the answer not in the manual?

Questions and answers

Summary of Contents for MiNGARDi Micro One 230

  • Page 1 Micro one 230V ∼ Micro one 24V...
  • Page 3 A04c A04s...
  • Page 5 B07c B07s...
  • Page 7: Installation

    Any other application of the actuator must be approved by Mingardi S.r.l. after technical testing Warning! of the application. Incorrect installation may make the only...
  • Page 8 Danger! • If the required stroke is greater than the height Danger of hands being crushed. When of the window, contact the Mingardi S.r.l. the window is moving, do not put your commercial technical service. hands between the fixed and moving •...
  • Page 9 3.8-mm drill bit. The fastening screws supplied are only for aluminium Loosen the two screws holding the clamps frames. Contact the Mingardi S.r.l. technical together so as to be able to insert the Micro One service for wooden, PVC or iron frames.
  • Page 10 Contact the Mingardi S.r.l. technical properly. service for wooden, PVC or iron frames. Now secure the clamps to the frame using 4...
  • Page 11 Contact the Mingardi S.r.l. technical properly. service for wooden, PVC or iron frames. Now secure the clamps to the frame using 4 screws code C094001600 (4.8x22 UNI 6954).
  • Page 12: Connecting To The Power Supply

    INSTRUCTIONS ON FITTING, USING AND Micro One MAINTAINING THE ACTUATOR • Signalling with load is delivered in the following CONNECTING TO THE POWER way: SUPPLY 230V AC Version: These wiring instructions are directed exclusively at specialised persons who are qualified to install electrical systems. Such With the chain completely retracted as long as persons must at all times comply with current the closing command stays on, a voltage the...
  • Page 13 INSTRUCTIONS ON FITTING, USING AND Micro One MAINTAINING THE ACTUATOR A - Wires, min. section 1 mm Micro One 230VAC WIRES/COLOURS COMPARATIVE TABLE B - Single-pole switch with mid OFF position (a= opens / b= closes). COLOUR NUMBER SIGNAL BLUE COMMON C - Bipolar main power supply switch with BLACK...
  • Page 14 INSTRUCTIONS ON FITTING, USING AND Micro One MAINTAINING THE ACTUATOR A - Wires, minimum section 1 mm Micro One 24VDC WIRES/COLOURS COMPARATIVE TABLE B - Single-pole switch with mid OFF position (a= opens / b= closes). COLOUR NUMBER SIGNAL C - Bipolar main power supply switch with BLUE POWER SUPPLY minimum contact opening of 3 mm.
  • Page 15: Stroke Adjustment

    INSTRUCTIONS ON FITTING, USING AND Micro One MAINTAINING THE ACTUATOR STROKE ADJUSTMENT Power up the actuator and make the entire chain go back in. Power up the actuator and make the Warning! chain come out until the limit switch trips. Check The actuator is adjusted to a 300-mm that the resulting stroke is the one you want (the stroke.
  • Page 16 INSTRUCTIONS ON FITTING, USING AND Micro One MAINTAINING THE ACTUATOR Applications Electric remote opening and closing of top-hung and hopper-frame windows in public, private and industrial buildings. Possible actuator controls • Manual commutator button. • Control unit for two actuators •...
  • Page 17: Specifications

    Dimensions 358x60x44 IP protection rating Product lifetime 10000 Variable stroke * From 13 to 305mm with12.5mm pitches Operating temperature -10 +40 ºC MINGARDI SRL - Via J.F.Kennedy, 11 - 40069 Zola Predosa (Bo) Italy - Tel. +39-051.6169111 - Fax +39-051.6169199...

This manual is also suitable for: