Any other application of the actuator must be approved by Mingardi S.r.l. after technical testing Warning! of the application. Incorrect installation may make the only...
Page 8
Danger! • If the required stroke is greater than the height Danger of hands being crushed. When of the window, contact the Mingardi S.r.l. the window is moving, do not put your commercial technical service. hands between the fixed and moving •...
Page 9
3.8-mm drill bit. The fastening screws supplied are only for aluminium Loosen the two screws holding the clamps frames. Contact the Mingardi S.r.l. technical together so as to be able to insert the Micro One service for wooden, PVC or iron frames.
Page 10
Contact the Mingardi S.r.l. technical properly. service for wooden, PVC or iron frames. Now secure the clamps to the frame using 4...
Page 11
Contact the Mingardi S.r.l. technical properly. service for wooden, PVC or iron frames. Now secure the clamps to the frame using 4 screws code C094001600 (4.8x22 UNI 6954).
INSTRUCTIONS ON FITTING, USING AND Micro One MAINTAINING THE ACTUATOR • Signalling with load is delivered in the following CONNECTING TO THE POWER way: SUPPLY 230V AC Version: These wiring instructions are directed exclusively at specialised persons who are qualified to install electrical systems. Such With the chain completely retracted as long as persons must at all times comply with current the closing command stays on, a voltage the...
Page 13
INSTRUCTIONS ON FITTING, USING AND Micro One MAINTAINING THE ACTUATOR A - Wires, min. section 1 mm Micro One 230VAC WIRES/COLOURS COMPARATIVE TABLE B - Single-pole switch with mid OFF position (a= opens / b= closes). COLOUR NUMBER SIGNAL BLUE COMMON C - Bipolar main power supply switch with BLACK...
Page 14
INSTRUCTIONS ON FITTING, USING AND Micro One MAINTAINING THE ACTUATOR A - Wires, minimum section 1 mm Micro One 24VDC WIRES/COLOURS COMPARATIVE TABLE B - Single-pole switch with mid OFF position (a= opens / b= closes). COLOUR NUMBER SIGNAL C - Bipolar main power supply switch with BLUE POWER SUPPLY minimum contact opening of 3 mm.
INSTRUCTIONS ON FITTING, USING AND Micro One MAINTAINING THE ACTUATOR STROKE ADJUSTMENT Power up the actuator and make the entire chain go back in. Power up the actuator and make the Warning! chain come out until the limit switch trips. Check The actuator is adjusted to a 300-mm that the resulting stroke is the one you want (the stroke.
Page 16
INSTRUCTIONS ON FITTING, USING AND Micro One MAINTAINING THE ACTUATOR Applications Electric remote opening and closing of top-hung and hopper-frame windows in public, private and industrial buildings. Possible actuator controls • Manual commutator button. • Control unit for two actuators •...
Need help?
Do you have a question about the Micro One 230 and is the answer not in the manual?
Questions and answers