Page 3
Notice Notice Cabletron Systems reserves the right to make changes in speciÞcations and other information contained in this document without prior notice. The reader should in all cases consult Cabletron Systems to determine whether any such changes have been made. The hardware, Þrmware, or software described in this manual is subject to change without notice.
Notice FCC Notice This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC rules.
Declaration of Conformity Application of Council Directive(s): ManufacturerÕs Name: ManufacturerÕs Address: European Representative Name: European Representative Address: Conformance to Directive(s)/Product Standards: Equipment Type/Environment: We the undersigned, hereby declare, under our sole responsibility, that the equipment packaged with this notice conforms to the above directives. Mr.
Chapter 1 Introduction Features ... 1-1 Related Manuals... 1-3 Getting Help ... 1-4 Chapter 2 Installing the 9C306 System Monitor Chapter 3 9C306 System Monitor Operation Monitoring Functions... 3-1 Fan Status ... 3-1 System Voltages... 3-2 LANVIEW LED... 3-2 Out-of-Band Management ... 3-3 COM1 and COM2 Ports...
System Management Bus-10 (SMB-10). Environmental/Power Monitoring The 9C306 System Monitor monitors and reports chassis power parameters, as well as the presence of the chassis cooling fan. Flash EEPROM The capability of downloading future Þrmware upgrades has been built into the 9C306 System Monitor.
Page 10
Introduction 9C306 STATUS EPIM Figure 1-1. The 9C306 System Monitor...
SmartSwitch 9000-6 Slot is running without interrupting network performance. LANVIEW LED The STATUS LED is built into the front of the 9C306 System Monitor. This LED indicates the status of the System Monitor and the presence or absence of system alarms.
Introduction Getting Help For additional support related to this device or document, contact Cabletron Systems using one of the following methods: World Wide Web Phone Internet mail Login Password To send comments or suggestions concerning this document, contact the Cabletron Systems Technical Writing Department via the following email address: TechWriting@cabletron.com Make sure to include the document Part Number in the email message.
Installing the 9C306 System Monitor The 9C306 System Monitor is installed in the slot marked SM at the right front side of the SmartSwitch 9000-6 Slot chassis, as shown in Figure 2-1. Install a System Monitor by following the steps below: Before handling the System Monitor Module or any SmartSwitch 9000 Interface Modules, attach the ESD (Electrostatic Discharge) Wrist Strap.
Page 14
Installing the 9C306 System Monitor If the SmartSwitch 9000-6 Slot chassis has not been powered up, make sure that all modules have been properly installed; then power up the SmartSwitch 9000-6 Slot chassis by following the steps in the SmartSwitch 9000-6 Slot 9C106 Chassis Setup and Installation Guide.
The System Monitor also includes LANVIEW LED for at-a-glance diagnostics. Monitoring Functions The 9C306 System Monitor Module monitors the following SmartSwitch 9000 functions: ¥ Fan status ¥ System voltages...
INB Termination Power Bus 12-volt internal line LANVIEW LED The LANVIEW LED on the front of the 9C306 System Monitor Module is an aid in troubleshooting. There is one LED visible to the user (Figure 3-1), which is the STATUS LED.
(LM) connection or an SNMP-based management application which does not use the same network connection to the chassis as Òuser data.Ó The 9C306 System Monitor provides three out-of-band management interfaces for managing the SmartSwitch 9000 system. These interfaces are listed below: ¥...
9C306 System Monitor Operation COM1 and COM2 Ports The 9C306 System Monitor front panel has two RJ45 communication ports for RS232 serial communication to and from the SmartSwitch 9000-6 Slot. Figure 3-2 illustrates a single RJ45 communication port. COM2 can be conÞgured to run the...
Specifications Safety The 9C306 System Monitor, when properly installed in the SmartSwitch 9000-6 Slot chassis, complies with the following safety speciÞcations and standards. ¥ UL 1950 ¥ CSA C22.2 No. 950 ¥ EN 60950 ¥ IEC 950 ¥ 73/23/EEC ¥ FCC Part 15 ¥...
Specifications Physical Dimensions 48.3 H x 30.5 W x 36.8 D centimeters (19 H x 1.2 W x 14.5 D inches) Weight Unit: 2.27 kilograms (5 pounds) Shipping: 2.27 kilograms (5 pounds) Environmental Operating Temperature: Operating Humidity: 5¡ to 40¡C (40¡ to 104¡F) 5% to 95% non-condensing...
EPIM Specifications Introduction The 9C306 System Monitor provides a port for Cabletron Systems EPIMs. EPIMs allow connection to the main network using different media types. Cabletron Systems offers a variety of EPIMs. SpeciÞcations for these EPIMs are detailed in the following sections.
EPIM Specifications EPIM-F3 The EPIM-F3 supports Single Mode Fiber Optic cabling. It has an internal Cabletron Systems FOT-F Fiber Optic Transceiver and is equipped with ST Connectors. Figure A-3 shows the EPIM-F3. SpeciÞcations for the EPIM-F3 are listed in Figure A-4 and Table A-3. Receive Sensitivity Maximum...
Page 25
Transmitter Power decreases as temperatures rise and increases as temperatures fall. Use the Output Power Coefficient to calculate increased or NOTE decreased power output for your operating environment. For example, the typical power output at 25° C is -16.4 dBm. For a 4° C temperature increase, multiply the typical coefficient (-0.15 dBm) by four and add the result to typical output power (4 x -0.15 dBm + -16.4 = -17.0).
EPIM Specifications EPIM-A and EPIM-X (AUI Port) The EPIM-A is a DB15 female connector used to attach segments to an external transceiver. The EPIM-X is equipped with dual internal transceivers. It has a DB15 male connector used to attach segments to an AUI cable. Figure A-5 shows both modules.
Management after connecting the UPS to the System Monitor (SM) module. Connecting a UPS to the System Monitor Module To connect a UPS to a System Monitor Module, use the RJ45/DB9 adapter and the RJ45 cable included in the cable kit shipped with the System Monitor Module, and follow the steps below.
9C306 STATUS COM2 Port EPIM 9C306 Module (Front View) Configuring COM Port for UPS After the UPS has been connected to the COM2 port, the COM2 port must be conÞgured for UPS Management. To conÞgure the COM2 port for UPS Management, follow the steps below.
Monitoring UPS Monitoring UPS Information about the operation of the UPS is obtained via Remote SNMP Management or locally by the LCD on the front of the UPS. Refer to the UPS UserÕs Guide, provided by the vendor, for detailed information on the UPS LCD.
Need help?
Do you have a question about the 9C306 and is the answer not in the manual?
Questions and answers