Advertisement

Quick Links

MONOCHROMATIC
User manual for art. 2030, 20301
Manuale d'uso per art. art. 2030, 20301

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the LEDCannon 2030 and is the answer not in the manual?

Questions and answers

Summary of Contents for STUDIODUE LEDCannon 2030

  • Page 1 MONOCHROMATIC User manual for art. 2030, 20301 Manuale d’uso per art. art. 2030, 20301...
  • Page 2 4 PIN connector - Connettore 4 PIN 4 PIN connectors 4 or 4 or WARNING FEMALE MALE IMPORTANTE ** DALI CONNECTION * DMX CONNECTION ** CONNESSIONE DALI * CONNESSIONE DMX DALI CONNECTION DMX CONNECTION SIGNAL SIGNAL GROUND DALI 1 N.C. DALI 2 N.C.
  • Page 3 INDEX Page 4 Safety informations / Informazioni di sicurezza Page 5 Introduction / Introduzione Page 6 Technical features / Caratteristiche tecniche Page 7 Main supply connection / Collegamento fonte di alimentazione Page 8 DMX connection / Collegamento DMX Page 10 Example of connection / Esempio di collegamento Page 11 Setup and configuration by DRS / Configurazione con DRS Setup...
  • Page 4 ........................ENG SAFETY INFORMATION (service personnel) IMPORTANT ! READ ALL CAUTIONS AND WARNINGS PRIOR TO OPERATE THIS EQUIPMENT. INSTRUCTION TO PREVENT INJURY OR DAMAGE DUE TO ELECTRIC SHOCK, FIRE, MECHANICAL HAZARDS, DANGEROUS MATTERS. • PROTECTION AGAINST DANGEROUS MATTERS At the end of its life, must be collected separately. It shouldn’t be thrown as urban waste and neither released in the environment. It must be collected from the nearest special waste collection point or consigned to your dealer that provides the service.
  • Page 5: Basic Kit

    ........................ENG INTRODUCTION CHECK THAT THE FIXTURE HAS NOT BEEN DAMAGED DURING TRANSPORT. IF IT HAS BEEN DAMAGED OR IT DOES NOT WORK, ADDRESS THE SELLER. WHETHER THE FIXTURE HAS BEEN SHIPPED TO YOU DIRECTLY, PLEASE CONTACT THE SHIPPING COMPANY. ONLY THE CONSIGNEE (PERSON OR COMPANY) CAN CLAIM FOR THESE DAMAGES.
  • Page 6 ........................ENG / ITA TECHNICAL FEATURES / CARATTERISTICHE TECNICHE ITEM FIXTURE [ KEY features ] Monochromatic 1 LED-ENGINE 400W Color temperature 6500K - CRI >90 Max power on LEDs 400W Lumen 25000 Lux values 14-15 lux at 500mt ı 7-8 lux at 700mt ı...
  • Page 7 ........................ENG / ITA CONNECTION TO THE MAIN POWER / CONNESSIONE ALLA RETE ELETTRICA This equipment must be earthed. Class I equipment. The power supply cord includes a protective earthing conductor as part of the cord. IMPORTANT: to ensure the protection rating of the fixture, in case of replacement of the conductor cable, refer to the CONDUCTOR SIZE TABLE Questo apparecchio necessita di messa a terra.
  • Page 8: Dmx Terminal Line

    ........................ENG / ITA CONNECTION TO THE DMX SIGNAL / CONNESSIONE AL SEGNALE DMX DMX TERMINAL LINE The wrong connection of the terminal line or its non-connection are probably the most frequent reasons of the lower DMX signal. The terminator is a terminal resistor fitted at the end of the cable. (see pict. 1) Termination resistor The terminal resistor should have the same value as the impedance of the connection cable (120 Ohm).
  • Page 9 IF YOU NEED TO MAKE ADDITIONAL CONNECTION CABLES, FOLLOW THE DESCRIBED SPECIFICATIONS / SE DOVETE REALIZZARE DEI CAVI DI COLLEGAMENTO AGGIUNTIVI (C), SEGUIRE LE SPECIFICHE DESCRITTE 4pin DMX OUT FEMALE MALE IP67 female connector (included) REAR VIEW OF WEIPU TYPE CONNECTORS Connettore femmina 4pin DMX IN (incluso)
  • Page 10 ........................ENG / ITA EXAMPLE OF CONNECTION DMX CONTROLLER - FIXTURES / ESEMPIO DI COLLEGAMENTO CENTRALINA - FARI Example 1/ Esempio 1 DMX out Last fixture/ Ultimo apparecchio fixture / fixture / apparecchio fixture / fixture / apparecchio apparecchio apparecchio Termination resistor/ Terminale di linea Example 2 / Esempio 2...
  • Page 11: Main Power

    ........................ENG SETUP AND CONFIGURATION BY DRS - DMX REMOTE SETUP The DRS it’s a new concept of professional LED Lighting fixtures suitable for outdoor permanent installations. The LED Lighting fixtures can be driven via DMX through a specific electronic device, the DRS DMX Remote Setup, that grant the possibility to set up the scenarios and the games remotely.
  • Page 12 ........................ENG SETUP AND CONFIGURATION BY DRS - DMX REMOTE SETUP dimmable version only / solo versione dimmerabile To make the set-up of the various fixture parameter, proceed as follow: •Disconnect the fixture to set-up from the other DMX/RDM devices •...
  • Page 13: Address (Addr)

    ........................ENG / ITA DRS MENU’ LIST / ELENCO MENU DRS Switching on the fixture you can see the model and the software version. For example: All’accensione, viene visualizzato il modello di apparecchio e la versione software. Per esempio: --> LED Cann --> 1_00 than it’s shown the fist menu poi viene visualizzato il primo menu Address (Addr)
  • Page 14 PHYSICAL / DIMENSIONI 322,00 200,00 EXTERNAL DRIVER LED CANNON rel. 2_08/21 - Studio Due...
  • Page 15 Doc. 2030 REV 1 - 03/21 StudioDue LED CANNON s.r.l. 03/2021 Dichiarazione di conformità Declaration of conformity La ditta: STUDIO DUE The firm: Strada Poggino, 100 01100 VITERBO ITALY dichiara sotto la propria responsabilità che il prodotto: declare under our sole responsability that the product: LED CANNON series IP65 art.
  • Page 16: Warranty Card

    WARRANTY / GARANZIA Warranty CARD Company name: ..........................Mr./Mrs./Miss: ..........................Address: ............................Tel. or E-mail : ..........................Dealer: ..................... SALE CONDITIONS 1) Price quoted are not inclusive of lamp and package. Package charge is 2% on the net price for all the items. These prices should be subject to possible variations for eventual rises of production costs or duties.
  • Page 17 this page is intentionally left blank / questa pagina è stata lasciata intenzionalmente bianca rel.2_08/21 - Studio Due...
  • Page 18 this page is intentionally left blank / questa pagina è stata lasciata intenzionalmente bianca rel. 2_08/21 - Studio Due...
  • Page 19 this page is intentionally left blank / questa pagina è stata lasciata intenzionalmente bianca rel.2_08/21 - Studio Due...
  • Page 20 Head Office: STUDIO DUE s.r.l. (I) Str. Poggino, 100 - 01100 Viterbo (Italy) tel. +39.0761.352520 fax +39.0761.352653 info@studiodue.com STUDIO DUE (UK) 3 Encon Court Owl Close Moulton Park Industrial Estate Northampton England UK - NN3 6 HZ tel. +44.1933.650.820 info@studiodue.co.uk www.studiodue.com...