Sharp R-300BW Service Manual page 21

Table of Contents

Advertisement

Pin No.
Signal
I/O
23
D6
OUT
24
D7
IN/OUT
25
D8
OUT
26
NC
27
F0
IN
28
F1
29
F2
IN
30
F3
IN
31-32
NC
33
XOUT
OUT
34
XIN
IN
35
CNTR
OUT
36
VDD
IN
Magnetron high-voltage circuit driving signal.
To turn on and off the cook relay (RY2). In 100%
POWER operation, the signals hold "L" level
during microwave cooking and "H" level while
not cooking. In other cooking modes (70%, 50%,
30%, 10%) the signal turns to "H" level and "L"
level in repetition according to the power level.
Terminal not used.
Oven lamp, turntable motor and fan motor driving signal(Square Waveform : 60Hz).
To turn on and off shut-off relay (RY1).
The square waveform voltage is deliv-
ered to the relay (RY1) driving circuit and
relay(RY2) control circuit.
No connection terminal.
Input signal which communicates the door open/close information to LSI.
Door closed; "H" level signal.
Door opened; "L" level signal.
Terminal not used.
Signal to synchronize LSI with commercial power source frequency.
This is basic timing for all real time processing of
LSI.
Signal coming from encoder.
Signal similar to INT. Pulse signals are input into F3.
No connection terminal.
Internal clock oscillation frequency control output.
Output to control oscillation input of XOUT.
Internal clock oscillation frequency input setting.
The internal clock frequency is set by inserting the ceramic filter oscillation circuit with
respect to XIN terminal.
Signal to sound buzzer.
A: Completion sound.
Power source voltage: 0V.
The power source voltage to drive the LSI is input to VDD terminal.
19
Description
ON/OFF time ratio in Micro
cooking
(a. 32second time base)
MICRO
COOK
100%
70%
50%
30%
10%
16.7 msec
During cooking
16.7 msec
2.0 sec
A
R-300BW
ON
OFF
32sec.
0sec.
24sec.
8sec.
18sec.
14sec.
12sec.
20sec.
6sec.
26sec.
H
L
H : GND
L (-5V)
H: GND
L: -5V