Power Check Sequence
1. AC input Check : SK100 (100~240Vac)
2. PWR-ON Check : Check Hole
- SET On : above 3V
- SET St-by : 0V
3. 13.2V DC Check :
- SET On : 13.2V
- SET St-by : 7.8V
4. MS Level Check : Check Hole
MS Level
Range [V]
LED On/Off
MS (0V)
0 ~ 0.25
MS (2V)
1.75 ~ 2.25
On (Home mode)
MS (3V)
2.75 ~ 3.25
On (Store Mode)
※ Home mode : General Customer
Store mode : use Store
5. LED voltage Check : P801, Pin 1-7
Picture Condition : VIVID (Back light 100)
272V, 410mA
Power Board Voltage / Current
Off
A12
P801
SK100 (AC input)
Copyright ⓒ 2020 LG Electronics Inc. All rights reserved.
Only training and service purposes.
MS
P201
PWR-ON
D201 (13.2V)