Tranquility Aluminum Tube Cased Coil (TAC)
Safety/Inspection

Table of Contents

3
4
5
6
7
Cased Coil for
Tranquility Split Series
Installation, Operation &
Maintenance Instructions
97B0100N01
Rev.: August 21, 2018
8 - 14
14
15
16

Advertisement

loading
Need help?

Need help?

Do you have a question about the Tranquility TAC026BM17S and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for ClimateMaster Tranquility TAC026BM17S

  • Page 1: Table Of Contents

    Tranquility Aluminum Tube Cased Coil (TAC) Cased Coil for Tranquility Split Series Installation, Operation & Maintenance Instructions 97B0100N01 Rev.: August 21, 2018 Table of Contents Model Nomenclature Installation 8 - 14 General Information Maintenance Safety/Inspection Warranty Specifications Revision History Dimensions...
  • Page 2 This page was intentionally left blank.
  • Page 3: Model Nomenclature

    Tranquility Aluminum Tube Cased Coil (TAC) R e v. : A u g u s t 2 1 , 2 0 1 8 Model Nomenclature 9 10 4 5 6 0 2 6 MODEL TYPE FUTURE USE T = TRANQUILITY HFC-410A COIL WIDTH CONFIGURATION Width, Inches...
  • Page 4: General Information

    ClimateMaster Tranquility Cased Coils are designed for are provided with each unit. Horizontal equipment is use with ClimateMaster indoor/outdoor split units and are designed for installation above false ceiling or in a ceiling available for vertical upflow or downflow, and horizontal left plenum.
  • Page 5 Tranquility Aluminum Tube Cased Coil (TAC) R e v. : A u g u s t 2 1 , 2 0 1 8 Safety � WARNING! � The installation of water source heat pump units and all associated components, parts and accessories which make up the installation shall be in accordance with the regulations WARNING! PROPOSITION 65: This appliance contains of ALL authorities having jurisdiction and MUST conform to...
  • Page 6: Specifications

    Tranquility Aluminum Tube Cased Coil (TAC) R e v. : A u g u s t 2 1 , 2 0 1 8 Specifications Table 1: Coil Specifications/Airflow Pressure Drop Wet Coil Static Pressure Drop (Inches W.C.) - Coil Only Face Case Area...
  • Page 7: Dimensions

    Tranquility Aluminum Tube Cased Coil (TAC) R e v. : A u g u s t 2 1 , 2 0 1 8 Dimensions Figure 1: Dimensions FRONT VIEW A MINUS ONE INCH [2.5 cm] ” [50.5 cm] SECONDARY DRAIN (HORIZONTAL) 3/4"...
  • Page 8: Installation

    Tranquility Aluminum Tube Cased Coil (TAC) R e v. : A u g u s t 2 1 , 2 0 1 8 Installation The Tranquility Cased Coils are designed for upflow, horizon- tal, and downflow applications. The coils have a dry nitrogen holding charge and are equipped with brazing stub refriger- ant connections for easy installation.
  • Page 9 Tranquility Aluminum Tube Cased Coil (TAC) R e v. : A u g u s t 2 1 , 2 0 1 8 Installation Table 3: Coil Application Applications Tranquility Cased coils can be applied in upflow, downflow, Furnace Width [cm] Coil horizontal right and horizontal left applications without Model...
  • Page 10 Tranquility Aluminum Tube Cased Coil (TAC) R e v. : A u g u s t 2 1 , 2 0 1 8 Installation FIGURE 4 INSTALLATION OF COIL MATCHED WITH A FURNACE TWO SIZES SMALLER Figure 3: Installation of coil matched with a furnace two sizes smaller URNACE TWO SIZES SMALLER Indicates airflow 6"...
  • Page 11 A restricted Nitrogen Braze line set will effect the performance of the system. ClimateMaster Split units are shipped with a filter drier (loose) inside the cabinet that must be installed in the liquid line at the Replace Caps after adjusting...
  • Page 12 Tranquility Aluminum Tube Cased Coil (TAC) R e v. : A u g u s t 2 1 , 2 0 1 8 Installation Figure 6: Air Coil Connection Evacuation LEAK TESTING - The refrigeration line set must be pressurized TXV w/Internal and checked for leaks before evacuating and charging the Bulb...
  • Page 13 Tranquility Aluminum Tube Cased Coil (TAC) R e v. : A u g u s t 2 1 , 2 0 1 8 Installation Duct Flanges • Make provisions for disconnecting and cleaning of the primary drain line should it become necessary. Install Field-installed duct flanges (4 pieces) are shipped with units.
  • Page 14: Maintenance

    Tranquility Aluminum Tube Cased Coil (TAC) R e v. : A u g u s t 2 1 , 2 0 1 8 Installation Figure 9: Typical Split/Add-on Coil Fossil Fuel Furnace Installation Air Temperature Limit Switch Cased Coil PVC Condensate with vented trap Low Voltage Compressor Section...
  • Page 15: Warranty

    Tranquility Aluminum Tube Cased Coil (TAC) R e v. : A u g u s t 2 1 , 2 0 1 8 Warranty c l i m a t e m a s t e r. c o m...
  • Page 16: Revision History

    97B0100N01 ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time for order may be changed without notice and may not be as described herein. Please contact ClimateMaster’s Customer Service Department at 1-405-745-6000 for specific information on the current design and specifications.