Includes two handests
PENDANT
D
Push and hold RAISE
or LOWER button
to position the sling bar
E
Push and hold RAISE
or LOWER button
to position the lift arm
Push and hold RAISE
F
or LOWER button
to position the lift arm
& bar simultaneously
Push and hold CLOSE
or OPEN button
B
to spread lift legs to
needed width
Forward/Reverse
H
Push FORWARD-
C
REVERSE button
C
until wheels
point forward
JOYSTICK
Battery
Status
Horn
D
Power
Button
Joystick
E
F
B
Rotationally
Sideways
Push SIDEWAYS
Push the apt
WHEEL ANGLE
button
H
until
button
C
wheels point
sideways
until the wheels
are at the
needed angle
BATTERY
CHARGING
Plug charger
jack into
battery and
AC plug into
outlet
800.255.3126 | wyeastmedical.com
DENALI
Instructions For Use
PRELIMINARY / SETUP
Before operating the DENALI, verify that:
Emergency
Stop knob
is popped out. (Twisting
clockwise restores
all functions)
or
H
EMERGENCY
Stop
(Push to stop all functions
Twist clockwise to restore)
600
Charger is unplugged
Both wheels are locked.
from outlet.
(Must be locked to drive)
SAFETY
Manual
EMERGENCY
EMERGENCY
Lowering of Sling Bar
Lowering of Sling Bar
(Turn handle counter-
(Push in black button to
clockwise to lower
lower sling bar)
sling bar)
52360-R04

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DENALI600 and is the answer not in the manual?

Questions and answers

Summary of Contents for WY'EAST MEDICAL DENALI600

  • Page 1 DENALI CONTROLS Includes two handests PENDANT JOYSTICK Instructions For Use Battery Status Push and hold RAISE Horn or LOWER button to position the sling bar Power Button Push and hold RAISE Joystick or LOWER button to position the lift arm PRELIMINARY / SETUP Before operating the DENALI, verify that: Push and hold RAISE...
  • Page 2 Press Any Button DENALI QUICK REFERENCE GUIDE Once To Power Lift READ USERS MANUAL BEFORE OPERATING Press Power Button To Power Drive On Adjust Console Height Power Functions Secure Sling onto Patient Be sure wheels are locked, and (see sling IFU) Charge Lift Emergency Stop When Done...
  • Page 3 DENALI Operator ’s Manual OPERATOR’S MANUAL DENALI POWER-DRIVEN MOBILE LIFT Model No. 52300 & 52400 52363 R05 Denali Power-Driven Mobile Lift Operator’s Manual 800.255.3126 | wyeastmedical.com Page 1 of 23...
  • Page 4 DENALI Operator ’s Manual WARRANTY Wy’East Medical Corporation (Wy’East) warrants to the original user the Denali Power-Driven Mobile Lift manufactured by the company is free from defects in material and workmanship under normal use and service. The term of warranty from the date of product receipt is for a period of two (2) years on mechanical lift components, one (1) year on electronic components, and one (1) year for the battery.
  • Page 5: Table Of Contents

    DENALI Operator ’s Manual Contents HOW TO USE THIS MANUAL: _________________________________________________ 4 DEFINITIONS: ______________________________________________________________ 4 SAFETY CONSIDERATIONS FOR ALL PROCEDURES: ____________________________ 6 PRIOR TO FIRST USE: _______________________________________________________ 6 SAFETY FEATURES: ________________________________________________________ 7 Emergency Stop Button ___________________________________________________ 7 Emergency Lowering of Sling Bar ___________________________________________ 7 Manual Lowering: ________________________________________________________ 7 Slack in the Sling Bar Strap: _______________________________________________ 7 Twist in the Sling Bar Strap:________________________________________________ 7...
  • Page 6: How To Use This Manual

    DENALI Operator ’s Manual Consistent with our policy of continuing product improvement, WY’EAST MEDICAL CORPORATION reserves the right to change these specifications without notice or obligation. INTRODUCTION HOW TO USE THIS MANUAL: This manual is designed to familiarize you with the operation of the Denali Power-Driven Mobile Lift. Read it thoroughly before using or servicing the equipment.
  • Page 7 DENALI Operator ’s Manual Your Denali Power-Driven Mobile Lift is designed for transferring and repositioning patients by utilizing a sling or other assistive device. • Low clearance for greater bed or stretcher access. • Adjustable leg width for easy access to wheelchair or commode. •...
  • Page 8: Safety Considerations For All Procedures

    DENALI Operator ’s Manual SAFETY CONSIDERATIONS FOR ALL PROCEDURES: 1. The Denali is designed to be used for lifting ONLY on level surfaces and driven on NO MORE THAN a 10 degree incline. 2. Inspect the lift functions prior to any patient use. Ensure all functions are in proper working order. 3.
  • Page 9: Safety Features

    DENALI Operator ’s Manual SAFETY FEATURES: Emergency Stop Button To stop all functions, push the red button until it locks. To resume functionality, turn the button clockwise until it clicks. Emergency Lowering of Sling Bar In the event of a handset malfunction, push the black button to lower the sling bar.
  • Page 10: Sling Usage

    DENALI Operator ’s Manual SLING USAGE: Refer to the sling IFU prior to use with the lift. Be sure the safety latches on the sling bar hooks are closed after attaching sling straps PREPARING TO USE: Adjusting the Control Console To adjust the control console height support it with one hand while pulling out the lock knob with the other and slide the console to the desired position.
  • Page 11: Driving Function

    DENALI Operator ’s Manual DRIVING FUNCTION: The drive control joystick controls driving speed and direction. It also provides a warning horn. BATTERY LIFE BATTERY LIFE The more the knob is moved in a given direction the faster the speed in that direction i.e. moving the knob all the way forward SIDEWAYS - ROTATIONAL FORWARD -...
  • Page 12 DENALI Operator ’s Manual The lift control handset controls the orientation of the legs. Push the buttons to move the legs to the desired position. Leg Position Control Buttons Refer to the instructions below. Push button to move legs closed. Push button to move legs open.
  • Page 13: Lifting Function

    DENALI Operator ’s Manual LIFTING FUNCTION: Sling Bar Position Control Buttons The lift control handset controls the lifting functions. Lift Arm Position Control Buttons Sling Bar & Lift Refer to the instructions below Arm Position Control Buttons Push buttons to move the sling bar up or down. Push buttons to move the lift arm up or down.
  • Page 14: Battery Function

    DENALI Operator ’s Manual BATTERY FUNCTION: Handle Retainer Lift handle, press in latches and lift the battery up to remove it. Latch To install battery hold with handle and align with socket on lift. Lower straight down onto the socket. Press in latches and secure them over the retainer.
  • Page 15: Operating The Denali Power-Driven Mobile Lift

    DENALI Operator ’s Manual OPERATING THE DENALI POWER-DRIVEN MOBILE LIFT: 1. Refer to the sling IFU prior to use with the lift. 2. OPEN the LEGS of the Denali to an appropriate width to maneuver the lift around a chair, wheelchair or bed. 3.
  • Page 16: Technical Specifications

    DENALI Operator ’s Manual TECHNICAL SPECIFICATIONS: PARAMETER SPEC • SWL 600 lbs • Device Part Number (3” casters) 52300 • Device Part Number (4” casters) 52400 • Unit of Measure 1 Each • Battery 15 Ah LiFePO • Number of Lifts per Charge •...
  • Page 17: Periodic Maintenance

    DENALI Operator ’s Manual PERIODIC MAINTENANCE: The following scheduled maintenance and inspections will help to ensure trouble-free operation of your Denali Power-Driven Mobile Lift. Not recommended for use in shower or wet environment. Do not pressure-wash the unit. Load Test: ONCE A DAY Following tests are to be performed with •...
  • Page 18: Electronics

    DENALI Operator ’s Manual ELECTRONICS: BATTERY CARE AND CAUTIONS: Handle batteries carefully. Battery packs may emit hydrogen gas. Do not bring fire or a heated object close to the battery pack, and never use the battery near a spark, fuses and/or equipment that emits sparks. Further, do not store the battery in a closed environment or incorporate it into a closed structure of an enclosure.
  • Page 19: Electronics Environmental Conditions

    DENALI Operator ’s Manual Battery packs contain dilute sulphuric acid, which is a toxic substance. If battery fluid leakage were to occur and make contact with skin or clothing, wash completely with clean water. Additionally, if the fluid gets in your eyes, wash them with clean water immediately, and see a doctor.
  • Page 20: Troubleshooting

    DENALI Operator ’s Manual TROUBLESHOOTING: SYMPTOM POSSIBLE CAUSE ACTION Battery is not fully charged. Charge battery. Battery is damaged. Replace battery. No power for driving or lifting. Red Emergency Stop switch Turn switch clockwise to reset. is pushed in. One or both wheel locking Unresponsive steering or Push both wheel locking levers levers not in locked (down)
  • Page 21: Factory Assistance

    DENALI Operator ’s Manual FACTORY ASSISTANCE: Expected lifetime: 8-10 years REPLACING PARTS: To order replacement parts, contact Wy’East Medical Customer Service. Include the following information with your request: 1. Serial and Model numbers of your Denali Power-Driven Mobile Lift. 2. Purchase date, if available. 3.
  • Page 22: Replacement Parts

    DENALI Operator ’s Manual REPLACEMENT PARTS: This manual provides maintenance and service information for the Denali Power-Driven Mobile Lift. If replacement parts are required, contact WY’EAST MEDICAL with the serial number of your Denali Power-Driven Mobile Lift to ensure the accuracy of replacement parts. Sling Bar 15”...
  • Page 23: Bio Med/Clinical Engineering Checklist

    DENALI Operator ’s Manual BIO MED/CLINICAL ENGINEERING CHECKLIST: • Inspect lift functions (Quarterly) – Check to ensure Description of Mechanical system: that the lift is free from damage. • Lift Strap – The lift strap system runs through the arm and mast through a sequence of rollers.
  • Page 24: Notes

    DENALI Operator ’s Manual NOTES: 52363 R05 Denali Power-Driven Mobile Lift Operator’s Manual 800.255.3126 | wyeastmedical.com Page 22 of 23...
  • Page 25: Contact Information

    DENALI Operator ’s Manual CONTACT INFORMATION For questions or information regarding other Wy’East Medical products, contact: Wy’East Medical Corporation 16700 SE 120th Ave. Clackamas, OR 97015, USA (503) 657-3101 (800) 255-3126 wyeastmedical.com info@wyeastmed.com 52363 R05 Denali Power-Driven Mobile Lift Operator’s Manual 800.255.3126 | wyeastmedical.com Page 23 of 23...