MANUAL ADDENDUM 4500L-3P-4728 1. GENERAL The 4500L-3P-4728 differs from the standard 4500L-3P. It has the MODE option and a TRMS Current Limit. The Current Limit function is adjusted to limit at the programmed value of current ±1% of the maximum 3-phase current. 2.
Page 3
Depress the MNU key several times until the first Menu screen is displayed as illustrated below: SNC = 01 RNG = 04 Enter the key sequence: 959 ENT Depress the MNU key several times until the Configuration Menu Screen is displayed as illustrated below: CFG = 16 ALM = 17...
Page 4
OUTPUT PHASE ADJUSTMENT ON CURRENT LIMIT BOARD Restore the correct phase configuration by performing the following steps: Depress the MNU key several times until the first Menu screen is displayed as illustrated below: SNC = 01 RNG = 04 Enter the key sequence: 959 ENT Depress the MNU key several times until the Configuration Menu Screen is displayed as illustrated below: CFG = 16...