Multi-Gas Detector ■ XP-3118 ■ XP-3168 Instruction Manual (For Combustible gas high-sensitivity type) This instruction manual explains to the use of two models listed on the left ● Please keep this instruction manual available for quick reference when needed ● Before use, carefully read this instruction manual and fully understand the content.
The following standard components are packed together with the Gas Detector. Carefully check the contents against the list when unpacking. If any components are missing or damaged, contact your New-Cosmos Electric representative. A replacement for the missing or damaged component will be sent to you.
Follow the explosion-proof conditions specified below for operating the Gas Detector. Operating conditions: Replace batteries only in area know to be NON-HAZARDOUS. ● Use the Gas detector in the carrying case specified by New-Cosmos Electric. ● As a comprehensive measure for the prevention of danger resulting from static electricity. ●...
Introduction 1. Introduction (continued from previous page) ■ Safe Operation In order to use the Gas Detector safely, be sure to observe the following items. DANGER If the gas alarm turns ON, immediately take all necessary measures to ● prevent explosion accidents and oxygen dificiency. WARNING Be sure to turn ON the Gas Detector in clean air.
Component Names and Functions 2. Component Names and Functions (10) (11) Name Function Alarm lamp Flashes at the time of gas alarming. Gas sampling hose connection port Connects to the Gas sampling hose. Exhaust port Exhausts sampled gas. Buzzer opening Sounds a buzzer.
Page 7
Component Names and Functions 2. Component Names and Functions (continued from previous page) Name Function LCD main screen Displays gas concentration and a variety of messages. A. Displays gas concentration. B. Displays the unit of measurement. C. Displays the remaining battery level. D.
Page 8
Component Names and Functions 2. Component Names and Functions (continued from previous page) 1-m gas sampling hose Name Function Gas sampling hose Leads gas to the Gas Detector. (1 m long) Coupler Connects to the Gas Detector. Prevents the penetration of water and dust into the Gas Detector. Drain filter (DF-4) The filter element (FE-2) is mounted.
Operating Procedure 3. Operating Procedure ■ Procedure Be sure to conduct a daily inspection before WARNING performing detection work (see page 24). Insert Turn ON Displays the gas Warms Turn OFF the Procedure t h e G a s concentr a tion Detects Gas Detector batteries.
Page 10
Operating Procedure 3. Operating Procedure (continued from previous page) 3. Detection Gas Concentration Screen ● Gas is detectable when the gas concentration screen is displayed. The LCD main screen will display GAS1 and the LCD sub screen will display GAS2. →...
Page 11
Operating Procedure 3. Operating Procedure (continued from previous page) Zero adjustment ● To conduct zero calibration, press the AIRADJ. switch for approximately three seconds. The buzzer will then beep once, followed by two beeps after a short pause. If zero calibration fails, the buzzer will beep once followed by continuous beeps.
Operating Procedure 3. Operating Procedure (continued from previous page) 〈AUTO range〉 When gas is detected, the digital numeric value and the bar graph level will increase simultaneously. If the bar graph level exceeds the full scale, the range will change from L to H automatically and the scale of the bar graph will change.
Operating Procedure 3. Operating Procedure (continued from previous page) ■ Functions and Setting Methods Press the MENU switch for approximately three seconds on the gas concentration screen. The buzzer will beep once, followed by two beeps after a short pause, and the following settings can be made and executed.
Operating Procedure 3. Operating Procedure (continued from previous page) ■ Peak Hold Settings With the peak hold function set, the peak value of gas concentration detected will be displayed continuously. (1) Press the MENU switch for approximately three seconds while the gas concentration screen is displayed to display the peak hold setting screen (see page 11).
Operating Procedure 3. Operating Procedure (continued from previous page) ■ Alarm Buzzer Silence Settings If the alarm buzzer is muted, the alarm buzzer will not sound when the gas concentration reaches the alarm level. (1) Press the MENU switch for approximately three seconds to display the alarm buzzer silence screen.
Page 16
Operating Procedure 3. Operating Procedure (continued from previous page) ■ Changing the Sample Gas Take the following steps to select the type of sample gas if there are two or more detectable gases. (1) Press the MENU switch for approximately three seconds while the gas concentration screen is displayed to display Flashes the sample gas selection screen.
Page 17
Operating Procedure 3. Operating Procedure (continued from previous page) ■ LCD Selection The LCD main screen will display GAS2. (1) Press the MENU switch for approximately three seconds while the gas concentration screen is displayed to display the LCD selection screen (see page 11). Flashes Press SYMBOL.
Operating Procedure 3. Operating Procedure (continued from previous page) ■ Logging Take the following steps to log the detected gas. Logger capacity (1) Press the MENU switch for three seconds while the gas concentration screen is displayed to display the logging start screen.
Operating Procedure 3. Operating Procedure (continued from previous page) ■ Data Logger Communications Screen Take the following steps to read logging data. In order to read data, a personal computer (see page 1) and Log Data Collection Set (optional item) are required.
Operating Procedure 3. Operating Procedure (continued from previous page) ■ Time Settings (1) Press the MENU switch for three seconds while the gas concentration screen is displayed to display the time setting screen. Refer to page 11. (2) Press the MENU switch to make time settings. The CL5 indication will then start flashing.
If the same error message appears again after the Gas Detector is turned OFF and ON several times, a sensor error or the end of the sensor lifetime may be considered. Contact your New-Cosmos Electric representative for repairs. This message appears when the battery voltage drops and the remaining battery level is low.
WARNING If water is drawn into the inside of the Gas Detector, the Gas Detector cannot detect properly. Contact your New-Cosmos Electric representative for repairs. (1) Remove the filter case of the drain filter.
Replacement of Consumable Parts 5. Replacement of Consumable Parts (continued from previous page) ■ Battery Replacement When the battery voltage drops and the battery is almost exhausted, the message Err-b will appear and the Gas Detector will not work. Replace the batteries. WARNING Use Panasonic LR6XJK, Toshiba One Screw...
Ensure the new sensor is the ● correct part number, manufactured by New Cosmos Electric Co. Ltd. (Sensor Model OS3M-SS for XP- 3180, OS3ME-SS for XP-3180E) ※XP-3000ATEXETO (Sensor Model OS3M-SS for XP- 3118, XP-3148, XP-3168) ※XP-...
Page 25
If Err-P is not displayed after several checks, wear and tear of the packing or malfunctioning of ● the pump unit may be considered. Contact your New-Cosmos Electric representative for repairs. WARNING Do not bring the gas detector into a hazardous location if it is malfunctioning.
ON again. if "Err-P" is not displayed the damage of the gas sampling pipe or the airtight defect of the sensor packing or pump diaphragm may be considered. Contact your New-Cosmos Electric representative for repairs or replacements. ■ Regular Inspection In order to maintain the accuracy of the Gas Detector, request a regular inspection from your New- Cosmos Electric representative.
Troubleshooting 7. Troubleshooting Before requesting repairs, please check the items in the following table. (When the instrument fails to operate, remove all batteries. After several minutes, install the batteries and try again.) ■ Gas detector Page for Symptom Cause Treatment reference T h e p o l a r i t y i s Install batteries again in the...
New Cosmos’s only obligation shall be, at New Cosmos’s sole option, replacement or repair of such non-conforming product or refund of the original purchase price of the non-conforming product. In no event will New Cosmos be liable for any other special, incidental or consequential damages or losses of any kind whatsoever, including but not limited to, loss of anticipated profits and any other loss caused by reason of non-operation of the product.
Specifications 9. Specifications ■ Gas Detector Product Multi-Gas Detector. Model XP-3118 XP-3168 Combustible gas and Combustible gas and Detectable gases flammable solvent Oxygen flammable solvent Oxygen steam steam Gas sampling method Automatic suction type Detection principle Catalytic combustion Galvanic cell...
Markings of explosion-proof 10. Markings of explosion-proof 1. Product mark detail 2. Um value mark detail Display each model XP-3118 XP-3148 XP-3168 3. Warning aticker (for leathercase) detail 4. Warning sticker (for body) detail List of hazardous locations standards with issue dates:...
Detection Principle 11. Detection Principle ● Catalytic Combustion Type A catalyst applied to the surface of a platinum coil causes catalytic combustion on the surface of the catalyst even when the gas concentration level in lower than the lower explosion limit. The temperature rise in this process increases the electrical resistance of platinum coil.
Glossary 12. Glossary Zero adjustment: Zero-point setting in pure air (21 vol% adjustment for Oxygen) Explosion-proof: A structure applied to electrical equipment to prevent the equipment from igniting the surrounding explosive atmosphere as the source of ignition. Intrinsically safe design: A structure whose inability to ignite explosive gases with a spark of electricity or a hot section generated in normal time or an accident has been confirmed in fire and other tests.
Page 36
● Loss of the Instruction Manual: If this instruction manual is lost, contact New Cosmos Electric or the nearest branch or sales office shown below. A copy of the instruction manual will be delivered to you. (A fee is charged.) Distributor/Retail Store XP-3000ATEXETF (01) 1303.200...