For 1-1/4" through 3" and most 4" lines (30mm-100mm) (33 pages)
Summary of Contents for General JET SET J-1450
Page 1
General Wire Spring Co. 1-412-771-6300 or 1-800-245-6200 Any alteration to equipment without prior written approval of the manufacturer will cancel any warranty or liability extended to the purchaser by manufacturer. For approval or assistance contact General Wire Spring Co. 8.914-323.0 / 97-6116...
The model and serial numbers will be found on a decal attached to the machine. You should record both serial number and date of purchase and keep in a safe place for future reference. General's Jet Set™ Manual Model J-1450 • Part No. 8.914-323.0/97-6116 • Revised 4/08...
UL approved ground fault circuit 11. General Wire Spring Co. will not be liable for any chang- interrupter (GFCI) power cord. es made to our standard machines or any components not purchased from General Wire Spring Co.
140°F (60°C). Using water hotter than 140°F (60°C) 1/8" hose using the AD-3 adapter. can cause damage to the pump and void the warranty. If jet is being used to clear ice blockages, see instructions on page 8. General's Jet set™ J-1450 • 8.914-323.0/97-6116 • reV. 4/08...
Foot Pedal (optional) Roof Hose Line to Foot Pedal on Roof Hose Reel Pressure Control valve Toolbox Unloader valve Motor GFCI Pulse Control Anti-Siphon valve valve Pump Pressure Gauge Inlet Strainer General's Jet set™ J-1450 • 8.914-323.0/97-6116 • reV. 4/08...
Page 7
___ detergent use. and P-traps Check the labels of any substance you will spray. If the label recommends any antidote or treatment, be ___ ready to use it. General's Jet set™ J-1450 8.914-323.0/8.914-323.0/97-6116 • reV. 4/08...
It is best to start at a 45° angle at a 7 to 10 ft. (2 to 3m) distance from object to be cleaned. Direct spray at close range can be powerful enough to cause damage. General's Jet set™ J-1450 • 8.914-323.0/97-6116 • reV. 4/08...
To adjust unloader, loosen lock nut and turn the knob clockwise to increase pressure and counterclockwise to decrease pressure. Caution: Do not overtighten unloader. Tighten lock nut after adjustments are made. General's Jet set™ J-1450 8.914-323.0/8.914-323.0/97-6116 • reV. 4/08...
™ gEnEral'S JET SET OPEraTOr’S ManUal PUMP MODEL NO. AR xTA2G15EbA-F8 JET SET MODEL J-1450 PART #5-2248 "E" version Ø24mm General's Jet set™ J-1450 • 8.914-323.0/97-6116 • reV. 4/08...
Do not run in bypass for more than 5 minutes. Do not let water supply exceed 140 F (60 IRREGULAR SPRAY Worn or partially clogged nozzle Clean or replace nozzles. PATTERN General's Jet set™ J-1450 • 8.914-323.0/97-6116 • reV. 4/08...
Page 17
Nozzle worn or wrong size Replace part as necessary. Piston or valve worn Replace part as necessary. ExTREME PRESSURE Adjusting nut turned completely into Back off adjusting nut. SPIkES unloader Clogged nozzle Clean or replace General's Jet set™ J-1450 8.914-323.0/8.914-323.0/97-6116 • reV. 4/08...
General Wire Spring Co. LIMITED ONE YEAR WARRANTY General Wire Spring Co. products are warranted to be free of defects in material and workmanship under normal use for the periods specified below. General Wire Spring Co. machines carry a one year limited warranty against defect or breakage except as noted below. Should any part break or fail to work properly in the year following purchase, it will be repaired or replaced at our discretion at no charge.