Do you have a question about the 406080A-FUR and is the answer not in the manual?
Questions and answers
Summary of Contents for Furun 406080A-FUR
Page 1
OPERATOR'S MANUAL AC/DC POWER SUPPLY UNIT 406080A-FUR Model www.furuno.com...
Page 3
Important notice General • This manual has been authored with simplified grammar, to meet the needs of international users. • The operator of this equipment must read and follow the descriptions in this manual. Wrong operation or maintenance can cancel the warranty or cause injury.
Page 4
How to discard this product Discard this product according to local regulations for the disposal of industrial waste. For disposal in the USA, see the homepage of the Electronics Industries Alliance (http://www.eiae.org/) for the correct method of disposal. In the European Union The crossed-out trash can symbol indicates that all types of batteries must not be...
Page 5
Safety instructions The following general safety precautions must be observed during all phases of operation, service and repair of this equipment. Failure to comply with these precautions or with specific warnings elsewhere in this manual violates safety standards of design, manufacture and intended use of the equipment.
Page 6
About the manual Intended readers This manual is an installation and user manual for the 406080A-FUR AC/DC Power Supply Unit. It is important that you observe all safety requirements listed in the beginning of this manual, and operate the 406080A-FUR AC/DC Power Supply Unit according to the instructions and guidelines in this manual.
Block diagram ................. 3 System configuration .............. 4 Chapter 2 Installation Unpacking ...............5 Installing the 406080A-FUR AC/DC Power Supply Unit ..6 Installing 2 or 3 406080A-FUR AC/DC Power Supply Units ..................15 Chapter 3 Service and repair Support, repair and service ...........19 Exchanging the fuses ............
Page 8
Table of contents Packing lists ...................PL-1...
Chapter 1 Introduction 1.1 General description 1.1.1 Positioning of connectors When mounted vertically the 406080A-FUR AC/DC Power Supply Unit fulfills IP32 in areas with more than 42 V and IP22 in other areas. The 406080A-FUR AC/DC Power Supply Unit can deliver...
Chapter 1: Introduction 1.2 Features The 406080A-FUR AC/DC Power Supply Unit has the following features: Two DC connectors, output, range: 28.7 V - 31.2 V Output power 300 W continuous, 370 W peak (2 min., 100-240 VAC) or 270 W continuous, 333 W peak (2 min., 90-100 VAC) Daisy-chaining of up to three units to give up to 1110 W.
Chapter 1: Introduction 1.3 Block diagram The drawing below shows the block diagram of the 406080A-FUR AC/DC Power Supply Unit. Mains AC AC/DC 28.7-31.2 VDC AC Input converter output AC LED 28.7-31.2 VDC input / output Output LED Battery+ 24 VDC...
Chapter 1: Introduction 1.4 System configuration The 406080A-FUR AC/DC Power Supply Unit is designed to be used with BGAN-X and FleetBroadband terminals. It can be used as a stand- alone DC power supply or as a building block in a larger power supply.
The 406080A-FUR AC/DC Power Supply Unit can be mounted on its own as a single unit, or you can daisy-chain and stack up to 3 units. The 406080A-FUR AC/DC Power Supply Unit can also be fitted in a 1 U rack mount.
You can mount the power supply in a vertical or horizontal position. When mounted in a vertical position, with the connector panel pointing downwards, the 406080A-FUR AC/DC Power Supply Unit fulfills IP32 in areas with more than 42 V and IP22 in other areas.
Page 15
The following drawing shows the 406080A-FUR AC/DC Power Supply Unit and the position of the mounting holes. It is mounted with four mounting bolts. • 4 mounting bolts for mounting 1 unit, M6X55 mm, DIN912 Unbrako To install the 406080A-FUR AC/DC Power Supply Unit, do as follows:...
Page 16
2. Fasten the cable-relief bracket directly to the wall, between the wall and the 406080A-FUR AC/DC Power Supply Unit, with four M4 x 6 mm screws. 3. Fasten the 406080A-FUR AC/DC Power Supply Unit to the wall with 4 mounting bolts, M6X55 mm, DIN912 Unbrako (included the delivery).
Page 17
To make room for the connector cables you must remove the U-shaped cutout for the respective cable in the plastic protective lid. Removing the protective lid (406080A-FUR AC/DC Power Supply Unit) To connect the cables you must remove the protective lid.
Page 18
• AC alarm output AC input The 406080A-FUR AC/DC Power Supply Unit is AC powered. To connect the AC input do as follows: 1. Remove the u-shaped cut-out for this input from the protective lid. 2. Connect the Mains cable to the connector marked MAINS AC.
Page 19
To connect to additional AC/DC Power Supply AC input 3. In order to be able to daisy-chain up to three 406080A-FUR AC/DC Power Supply Units the Mains AC connector has two terminals: • Use one terminal for the incoming mains power.
Page 20
DC output or optional input for daisy-chaining The second DC connector (DC 2) of the 406080A-FUR AC/DC Power Supply Unit can be used for 2 purposes, to provide DC output or to serve as an input connector when daisy-chaining up to 3 406080A-FUR AC/DC Power Supply Units.
Page 21
Chapter 2: Installation Battery input You can connect an external 24 V emergency battery to the 406080A- FUR AC/DC Power Supply Unit to make sure the unit is operational in case the AC input fails. The battery input is protected against wrong polarity of the battery.
Page 22
Chapter 2: Installation AC alarm output The AC alarm output provides an alarm signal when the 406080A-FUR AC/DC Power Supply Unit cannot deliver the required power from the AC input. This is the case when • No AC power is present.
Chapter 2: Installation 2.3 Installing 2 or 3 406080A-FUR AC/DC Power Supply Units You can mount up to three 406080A-FUR AC/DC Power Supply Units in a vertical (recommended to use the Wall- mount tray, heavy duty, with cable-relief bracket, order number: 406080A-opt.001) or...
Page 24
Chapter 2: Installation The following drawing shows the specifications of the mounting bolts needed when installing two or three units on top of each other. • 2-block mount: 4 x M6X100 mm DIN912 Unbrako • 3-block mount: 4 x M6X140 mm DIN912 Unbrako...
Page 25
Chapter 2: Installation 2.3.1 Wiring for daisy-chaining The following drawing shows how to wire the 406080A-FUR AC/DC Power Supply Units when daisy-chaining two or three units. 406080A-FUR 406080A-FUR 406080A-FUR To daisy-chain two or three 406080A-FUR AC/DC Power Supply Units proceed as follows: 1.
Page 26
Chapter 2: Installation This page is intentionally left blank.
Chapter 3 Service and repair The 406080A-FUR AC/DC Power Supply Unit is designed to operate without preventive maintenance. Repair or repair attempts performed by unqualified personnel may limit the warranty. The warranty on the system is defined and outlined by the distributor that supplied the 406080A-FUR AC/DC Power Supply Unit.
Chapter 3: Service and repair 3.2 Exchanging the fuses The 406080A-FUR AC/DC Power Supply Unit has fuses to secure AC input and input from an external battery. Fuse, AC input 2 fuses, battery input To exchange the AC fuse, do as follows: 1.
Chapter 3: Service and repair Exchanging the BATTERY fuses To exchange the two BATTERY fuses, do as follows: 1. Locate the fuses for battery plus and one for battery minus. These are accessible from outside the housing, They are is positioned to the right of the protective lid.
Page 30
Chapter 3: Service and repair 3.3.1 Repacking for shipment Should you need to send the product for repair, please read the below information before packing the product. The shipping carton has been carefully designed to protect the 406080A- FUR AC/DC Power Supply Unit and its accessories during shipment. This carton and its associated packing material should be used when repacking for shipment.
Appendix A Technical specifications The following table shows the electrical and environmental specifications of the 406080A-FUR AC/DC Power Supply Unit. Specifications Value Output power at 100 VAC - 300 W continuous 240 VAC 370 W peak (2 min.) Output power at 90 VAC -...
Page 32
Appendix A: Technical specifications Specifications Value Survival temperature (power -40° to +80° C Dimensions H: 46.5 mm, L: 354 mm, W: 265 mm Weight Approx. 3.7 kg Compass safe distance 30 cm...
Appendix B Wall-mount tray (option) B.1 Overview A Wall-mount tray, heavy duty, with cable-relief bracket is available and can be ordered (order number: 406080A-opt.001). Up to 3 406080A-FUR AC/DC Power Supply Units can be mounted on this tray.
Page 34
Appendix B: Wall-mount tray (option) B.1.1 Dimensions and weight B.1.1.1 Dimensions B.1.1.2 Weight The Wall-mount tray, heavy duty, weighs 2.5 kg.
You must connect the units as shown in the drawing. This is Important to make sure that a single connector is never overloaded with more than 30 A. C.1 Wiring 4 or more 406080A-FUR AC/DC Power Supply Units 406080A-FUR 406080A-FUR...
Page 36
Appendix C: Special installation This page is intentionally left blank.
Appendix D: Declaration of conformity D.2 CE (LVD & EMC) The 406080A-FUR AC/DC Power Supply Unit is CE certified (LVD & EMC directives) as stated in the “Declaration of Conformity with LVD and EMC Directives”.
Need help?
Do you have a question about the 406080A-FUR and is the answer not in the manual?
Questions and answers