OMNI EXPRESS PATIENT MONITOR
OPERATOR'S MANUAL
M3

Advertisement

Table of Contents
loading

Summary of Contents for Infinium M3

  • Page 1 OMNI EXPRESS PATIENT MONITOR OPERATOR’S MANUAL...
  • Page 2 Portab Copyright INFINIUM MEDICAL, INC. owns all right to this unpublished work and intends to maintain this work as confidential copyright. This publication is to be used solely for the purpose of reference, operation, maintenance, or repair INFINIUM equipment. No part of this can be disseminated for other purposes.
  • Page 3: Table Of Contents

    Portable Patient Monitor Manual Content Chapter 1 Introduction 1.1 Profile 1.2 Safety Information 1.3 Explanation of Symbols Chapter 2 Overview of the Monitor 2.1 Appearance of Monitor 2.2 Special Features 2.3 Specification Chapter 3 Menu Instruction 3.1 Display Screen 3.2 Menu Operation 3.2.1System Menu 3.2.2 Trend Table 3.2.3 Alarm Setup...
  • Page 4: Chapter 1 Introduction

    If monitor becomes accidentally wet during use, discontinue operation of the monitor until all affected components have been cleaned and permitted to dry completely. Contact your local INFINIUM representative if additional information is required. When replace the fuse, please with the new one which the type and the rating current are the same with the used one.
  • Page 5: Explanation Of Symbols

    The medical equipment must be manipulated by personnel who have already got relative training of operation. For safe and accurate operation, use only INFINIUM recommended patient cable, lead wires, cuffs, hose, sensors, tubing, etc. Request for the special children or infant accessories when monitor infant.
  • Page 6 Portable Patient Monitor Manual System menu Trend table Heart Beat Detected Description of Abbreviation ── Electrocardiograph ── Heart Rate Resp ── Respiration SPO2 ── Arterial oxygen saturation NIBP ── Non-invasive blood pressure ── Invasive blood pressure ── Systolic pressure ── Diastolic pressure ──...
  • Page 7: Chapter 2 Overview Of The Monitor

    Portable Patient Monitor Manual CHAPTER 2 Overview of the Monitor 2.1 Appearance of Monitor Screen display Alarm Indicator If there is physiological alarm, it demonstrates that some parameters measuring scale is beyond alarm limitation, in the meantime, the indicator begin flashing. According to the various alarm level, there are three alarm-level in all for selection: High level: when alarm occurs, the color of the indicator becomes red and starts flashing once every one second.
  • Page 8 Portable Patient Monitor Manual Print: Printer button, when Monitor equipped with printer which could be internal thermal array recorder or printer as a peripheral and then press the button, the correspondent data will be printed out. Rotary knob: User rotate this knob to select and enter desired item, it is similar in function with PC mouse. For more information, please refer to section of Menu operation.
  • Page 9: Special Features

    Portable Patient Monitor Manual Rear Panel (1) NET: net access point: connecting with the central monitoring system through the standard RJ-45 (2) (3)USB1,USB2 (reserved) (4)Speaker (reserved ) (5) AUX OUTPUT (reserved) (6)VGA MONITOR:CRT exteriorly connecting screen and standard VGA. (7)Ground terminal: Ground terminal of equivalent potential. (8)Power: AC Power supply: 100-230 V(AC), 50/60(Hz);fuse: 1.6A 2.2 Special Features Portable, compact, AC power and internal rechargeable battery...
  • Page 10: Specification

    Portable Patient Monitor Manual 2.3 Specification Dimension: 258mmX120mmX243mm Weight: 3.5kg with 0.79kg battery 4.5kg with package Packing list: Monitor. ECG cable, spo2 sensor, NIBP cuff, temp sensor, printer (optional) 1、 、 、 、 ECG 7-Lead: I、II、III、aVL、aVR、aVF、V Display Gain Scales:2.5mm/mV, 5mm/mV,7mm/mV,10mm/mV,15mm/mV,20mm/mV, 25mm/mV Sweep Speed: 12.5mm/s、25mm/s、50mm/s three classes can be changed...
  • Page 11 Portable Patient Monitor Manual Measurement Accuracy: Static Pressure: ±3mmHg Pulse Rate: ±2% 4、 、 、 、 Resp: ● Trans-thoracic impedance (RA-LL) Range: 2bpm~100bpm Accuracy: 15bpm~60bpm ≤2bpm 60bpm ~100bpm ≤5bpm ●CO2 method ( The standard monitor without this method) RR Range 2bpm~60bpm(including Neonatal)...
  • Page 12 Portable Patient Monitor Manual 8、 、 、 、 Default Alarm Setup: Parameter Systolic Diastolic Mean Arterial SpO2 TEMP (bpm) (℃) (bpm) (kPa) (kPa) (kPa) (bpm) (Fº) (mmHg) (mmHg) (mmHg) Upper Range 21.3 12.6 14.6 39.5 103.1 Lower Range 12.0 96.8 9、...
  • Page 13: Chapter 3 Menu Instruction

    Portable Patient Monitor Manual Chapter 3 Menu Instruction 3.1 Display Screen DEMO State HR,Lead, ECG analysis of ECG waveform ST segment Blood pressure value Hand/auto operating switch ECG waveform Measuring unit Measuring count down SPO2 waveform SPO2 RESP waveform Difference of T1&T2 channels Data Table T1 channel...
  • Page 14: Menu Operation

    Portable Patient Monitor Manual Fig.2 Fig.3 3.2 Menu Operation 3.2.1 System Menu...
  • Page 15 Portable Patient Monitor Manual In monitoring status, rotate the knob to highlight the MENU icon, and then press the knob, the menu bar of “system setup” appears on the bottom of screen. The “system setup” menu includes 6 items. Rotating and pressing the knob to select the menu to be set.
  • Page 16 Portable Patient Monitor Manual Fig.5 Mode 3: IBP Extend: (Only the IBP type unit has this picture, supplying according to custom’s order) Fig.6 Mode 4: ECG Extent:...
  • Page 17 Portable Patient Monitor Manual Fig.7 Mode 5: Graph Ext Fig.8 Extend SYSTEM: Manufacturer setup, please keep them unchanged. DEMO: You can open or close the measuring demonstration by setting this menu. FAN: You can open or close the FAN by setting this menu. When the fan is opened and the...
  • Page 18: Trend Table

    Portable Patient Monitor Manual ℃ internal temperature of the monitor is over 50 , the fan will start working automatically, and ℃ it will be off automatically when the temperature is below 45 . Bed Setup: Indicates the only bed number of the patient being monitored when the patient monitor is connected with the workstation, it always shows on the top left corner in the monitor status frame.
  • Page 19 Portable Patient Monitor Manual pop out the menu shown as below: A. Table display A.1 Enter menu of trend table: The latest 72-hour data table can be displayed at every 1 minute. The first column shows the items of the parameters. The first and the second line of the table indicate the date and time of measurement respectively.
  • Page 20 Portable Patient Monitor Manual Fig.10 A3 IBP Trend Table( Only your unit install the IBP module, you can see this table.) Fig.11 A4 Alarm Record:...
  • Page 21 Portable Patient Monitor Manual Fig.12 Standard type Fig.13 Standard &CO2...
  • Page 22 Portable Patient Monitor Manual Fig.14 Standard & IBP B. GRAPH Take the HR graph for example: Fig.15...
  • Page 23: Alarm Setup

    Portable Patient Monitor Manual Trend time: Time span of every page, there eight hours, 24hours and 72 hours for selection. When select “ERASE?” you can delete the former trend records (it needs restarting). C. OxyCRG OxyCRG display the HR, SPO2 and the RESP rate at the same time. Fig.16 D.
  • Page 24: Ecg Setup

    Portable Patient Monitor Manual Silence OFF Silence ON Highlight 3.2.5 ECG Setup: In monitoring status, rotate the knob to highlight the “ECG”, and then press the knob, the menu of “ECG setup” appears on the bottom of screen as shown below. A.
  • Page 25: Nibp Setup

    Portable Patient Monitor Manual OP MODE :Operation mode, bandwidth: 1 - 25 Hz MO MODE :Monitor mode, bandwidth: 0.5 - 75 Hz DG MODE :Diagnosis mode, bandwidth: 0.05 - 100 Hz FILTER ON :bandwidth: 1- 50 Hz ,display the ECG waveform in LEAD OFF condition. 3.2.6 NIBP setup Under the monitoring state, rotate the switch until the cursor focus on the position of NIBP.
  • Page 26: Resp Setup

    Portable Patient Monitor Manual A. AMPLITUD Under the menu of SPO2 setting up select AMPLITUD, then rotate the switch to choose suitable the SpO2 wave amplitude.5 items in all for selecting. B. AVERAGE Under the menu of SPO2 you can notice the item of Average, which means the average pulse rate according to calculation of SPO2 measurement for each time.
  • Page 27: Temp Setup

    Portable Patient Monitor Manual Select “ALARM” in RESP menu to call up the sub-menu and ready to adjust alarm level and related parameters. APNEA: You can set the APNEA on or off by this item. You can set the examination time during 5-90 seconds, and the interval time is five seconds.
  • Page 28: Printer

    IBP data table. ABP:Directness artery pressure PAP:Pulmonary artery pressure CVP:Center vein pressure 3.3 Printer Connection for printer Outer printer: connect the printer to the PRINT port. Inner printer: We have inner printer type 6000DP M3, supplying according to the customs order.
  • Page 29: Chapter 4 Operation

    Portable Patient Monitor Manual Chapter 4 Operation for the Equipment 4.1 ECG 4.1.1 How to put the electrode in place. 12 pieces of ECG leads are available. To activate one lead which directly link to patient’s correspondent body feature, then the associated waveform will be shown on the screen. You must be cautious when install the electrode.
  • Page 30 Portable Patient Monitor Manual Black (N) electrode: be placed on the right hypogastrium. Green (F) electrode: be placed on the left hypogastrium. White(C) electrode: be placed on the chest as illustrated. Recommended ECG lead connection. WARNING When using electrosurgery equipment, leads should be placed in a position in equal distance from electrosurgery electrotome and the grounding plate to avoid cautery.
  • Page 31: Spo2

    Portable Patient Monitor Manual Cleaning: Use the warm water or 70% alcohol solution to submerge an velvet cloth to start cleaning operation. Sterilization It is suggested sterilization on instrument is going only when it is required by hospital regulation in order to avoid long-term damage on instrument. We also suggest that the product used to sterilize our instrument is cleaned first.
  • Page 32 Portable Patient Monitor Manual 4.2.4 Precaution for SPO2 measuring Please apply the same brand SPO2 probe produced by designated manufacture, other unauthorized probe may not be compatible with the SPO2 module. Please do not use defective SPO2 probe, otherwise may cause damage to the SPO2 module.
  • Page 33: Nibp

    Portable Patient Monitor Manual cable is detected, stop using it immediately. Cleaning: Moisten the soft cloth or gauze with alcohol and use it to wipe the surface of sensor, and then use the clean cloth to dry it. The same method can be used to clean the light source and photo detector.
  • Page 34 Portable Patient Monitor Manual successively measure patient’s BP after taking break for the time you set in “CYCLE” item If you press “START” menu during AUTO mode, the measurement in progress will stop to another manual measurement. After this manual measurement, the device will enter AUTO monitoring mode again.
  • Page 35: Resp(Without In Standard Version, According To Customs Order)

    Portable Patient Monitor Manual Avoid squeezing and bonding cuff bag to have bad effect on BP measuring. Inaccurate measurements may result from such causes: a. Limb’s twitch and tremble will cause inaccuracy or prolonged the cycling of measurement, serious tremble will lead to the failure of measure. b.
  • Page 36: Temp

    Portable Patient Monitor Manual Warning The monitor just can measurement HR times can not be sued to measurement asphyxia and monitor neonate. The monitor measures respiration from the amount of thoracic impedance between ECG electrodes, the placing of ele ctrodes is important( detailed information please refers to ECG chapter).
  • Page 37: Chapter 5 Maintenance And Troubleshooting

    Portable Patient Monitor Manual Chapter 5 Maintenance and Troubleshooting 5.1 Maintenance Customers should responsible for periodic maintaining of the product and its accessories. It is very important for our company to warranty the service and repairs. We reserve the rights to change the time limit of warranty and replacement if the following steps are non-implemented: ⑴An effective maintenance plan should be designed for the product and its reusable accessories.
  • Page 38: Troubleshooting

    Portable Patient Monitor Manual ● Do not power on/off frequently. ● Take down and safekeeping probes, lead wires, gluey tube after using product. ● Please hold the product in packaging if the product would not work for a long time. ●...
  • Page 39 Portable Patient Monitor Manual 2、Exemption and restriction: a) Warranty does not apply to the damage or loss sustained due to well-known act of god, such as fire, earthquake, flood, thunder, cyclone, hail, electrical storm, blast, building collapse, commotion, etc. b) Non-service items: ·The cost and insurance of dismantling and testing, overhauling, reinstall, transfer, moving the instrument or parts.
  • Page 40: Storage And Transportation

    Portable Patient Monitor Manual ● Not original package for transportation. ● Any malfunction caused by non professional worker or unauthorized personnel for machine repair. ● Do not read the user instructions carefully。 5、Customer special warranty period Due to we stipulate the warranty period according to the relevant electronic regulation of country, which we stipulate is on year, accessory is three months.
  • Page 41: Appendix: Ha,Hv,St Segment Analysis

    Portable Patient Monitor Manual 5.6 Appendix: Arrhythmia, HR variation, ST analysis (VFE1.0.0 no support for this function) In order to get the better result, the highly efficient ECG waveform is a must. Too much noise and interruption will affect the accuracy. In view of the long time patient monitoring, therefore, the results from the monitor is only for reference at anytime and in any situation.