1.5KW&2.2KW
Port Table
Port
Function
1
PE
2
N
3
L
4
Braking resistor output -
5
Braking resistor output +
6
Motor brake -
7
Motor brake +
8
Reserved
9
Safety input 1
10
Safety input 2
11
Com/Gnd
12
DC24V+
13
Automatic open input
14
Partial open input
15
Start input
16
Com/Gnd
17
Open limit switch input
18
Close limit switch input
19
Lock input
20
Com/Gnd
21
DC24V+
22
Output 1A
23
Output 1B
24
Output 2A
25
Output 2B
26
Output 3A
27
Output 3B
28
Output 4A
29
Output 4B
30
RS485+
31
RS485-
32
Com/Gnd
33
Manual open input
34
Manual close input
35
Manual stop input
36
Emergency stop input
High Speed Door Servo Control System
AC220V input
DC 24V
NO (Safety edge, photocell, etc.), stop
NO (Safety edge, photocell, etc.), reverse to open limit
when closing
NO (contact radar, and the sense)
NO
NO
NO
NO
NO
1A-1B normally open, set the function selection
"Output 1 Config" 1A-1B is closed
2A-2B normally open, setting "Output 2 Config"
Function selection 2A-2B is closed
3A-3B normally open, set the function selection
"Output 3 Config" 3A-3B is closed
4A-4B normally open, setting "Output 4 Config"
Function selection 4A-4B is closed
NO
NO
NO
NC
24
Remark