Page 1
Instruction Manual MANFC440 REV B 15/10/15 EVAPORATIVE AIR CONDITIONER FC440, FC700 SILVAN AUSTRALIA PTY. LTD. ABN 48 099 851 144 VICTORIA (HEAD OFFICE) Hamilton, New Zealand Telephone: +61 (03) 9215 2700 Telephone: +64 (07) 8496 033 Fax: +61 (03) 9215 2701 Fax: +64 (07) 8496070 www.silvan.com.au...
Page 2
INTRODUCTION Thank you for purchasing our product. We trust it will give you long and trouble-free service. The cooler is a high-tech product, showing simplicity and outstanding reliability. Its working principle is that water evaporation uses up the surrounding heat and causes the temperature to cool down.
Page 3
Silvan Warranty Our goods come with guarantees that cannot be excluded under the Australian Consumer Law. You are entitled to a replacement or refund for a major failure and for compensation for any other reasonably foreseeable loss or damage. You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure.
TECHNICAL SPECIFICATIONS MODEL FC440 FC700 Max Airflow (M 12000 18000 Power supply/Frequency (V/HZ) 220-240/50 220-240/50 Power Consumption (W) Fan Style Axial Axial Water Consumption (L/H) 8-10 10-15 Water Tank Capacity (L) Dimension (L*W*H) (mm) 925×580×1440 1120x600x1650 Weight (kg) Effective Cooling Area (M...
IMPORTANT REMINDERS Please read the manual carefully before operating the cooler. A) Operating conditions: 1- Temperature: 18°C to 45°C; Water Temperature: < 45°C. 2- Power supply must not exceed the required voltage (+/-) 5%. 3- Air supply must be largely free of dust or extra cleaning is required. B) Protect the power cable from vehicles or foot traffic.
KEY COMPONENTS BACK SIVEL CASTER WITH LOCK FRONT SWIVEL CASTER...
Page 7
OPERATION INSTRUCTION Before attempting to operate or install this unit carefully read and take note of the following safety warnings. Failure to comply with these warnings may result in serious injury or death. 1. All electrical repairs must only be carried out by a suitably qualified electrician, after all power is disconnected.
5)To prevent build-up of algae and biological organisms in the reservoir, regularly add chlorine/bromine tablets as per tablet manufacturer recommendation for evaporative cooler reservoirs. SPARE PARTS: Cooling Pad to FC440-01 FC440-05 Level indicator Suit Model FC440 Cooling Pad to FC700-01 FC440-06 Float Valve Suit Model FC700 FC440-02 Water Pump...
TROUBLESHOOTING MALFUNCTION REASON SOLUTION - Check unit is plugged in - Check power point is live by - No power plugging in another appliance. - LCD screen - Fuse is blown - There is a fuse on the control stays dark - Main control board.
Need help?
Do you have a question about the FC440 and is the answer not in the manual?
Questions and answers