Do you have a question about the Touchless ADO and is the answer not in the manual?
Questions and answers
Summary of Contents for Sargent and Greenleaf Touchless ADO
Page 2
LOW ENERGY APPLICATION NOTE When using the Touchless ADO, S&G recommends the use of a door-mounted presence sensor on the approach side of the door to be used as a secondary activation device. This type of sensor can be installed at time of installation or can also be retrofitted.
[t] 800.826.7652 ■ 859.885.9411 ■ E-mail: (Information Required) ■ One Security Dr. Nicholasville, Kentucky 40356 PRODUCT DESCRIPTION & SPECIFICATIONS The S&G Touchless ADO Low Energy Swing Door Operator provides safe and reliable point of entry door control featuring a state-of-the-art microprocessor-based controller with electro-mechanical drives. The unit is self-tuning and self-learning while offering non-handed operation, full mechanical stops, and a variety of interface options for sensors, push-plates, fire alarms, and electrified locks.
Page 5
PULL or PUSH operator, the motor assembly will likely be shipped from the factory in the appropriate PULL or PUSH orientation. Take note of the orientation before removing the motor assembly (i.e. Is the motor towards the center of the housing, or the edge of the housing) S&G TOUCHLESS ADO.docx REV - 08/2021...
Page 6
Next, locate & loosen the 4 side hex bolts (see above) using a 5mm allen wrench. Slide the bolts away from the motor drive assembly allowing the assembly to be removed. The drive plate will be held in place by the 5 hex bolt. S&G TOUCHLESS ADO.docx REV - 08/2021...
Page 7
Remove the drive plate by shifting the drive plate to the left and lifting the drive plate away from the back plate. Key hole slots behind drive plate Fixed positioning bolt – do not attempt to remove S&G TOUCHLESS ADO.docx REV - 08/2021...
SWING frame face. 8" MAX REVEAL SECTION VIEW – PUSH (N.T.S) ” Typ. w/ 20mm spindle PULL ARM APPLICATIONS: Bottom of 1-½” " operator is mounted 1.5” up from the bottom side of top door frame DOOR SWING 0" REVEAL SECTION VIEW – PULL (Aluminum & Glass Door – N.T.S) S&G TOUCHLESS ADO.docx REV - 08/2021...
Page 9
SARGENT & GREENLEAF ■ WWW.SARGENTANDGREENLEAF.COM [t] 800.826.7652 ■ 859.885.9411 ■ E-mail: (Information Required) ■ One Security Dr. Nicholasville, Kentucky 40356 Backplate should overlap hinge side jamb tube by 1.5” (See figure below). S&G TOUCHLESS ADO.docx REV - 08/2021...
Page 10
[t] 800.826.7652 ■ 859.885.9411 ■ E-mail: (Information Required) ■ One Security Dr. Nicholasville, Kentucky 40356 DOOR PREP DRAWINGS: PUSH SIDE INSTALLATION – SINGLE DOOR Opening Width Housing Width X Dim 36" 39" 6.25" 42" 45" 12.25" 48" 51" 18.25" S&G TOUCHLESS ADO.docx REV - 08/2021...
Page 11
99" 24-7/16" 22-7/8" NOTES: Hollow metal frame with 5/8” stop height shown. “A” dimension is only located on the 72” & 96” operator “C” dimension is only located on the 84” & 96” operator S&G TOUCHLESS ADO.docx REV - 08/2021...
Page 12
[t] 800.826.7652 ■ 859.885.9411 ■ E-mail: (Information Required) ■ One Security Dr. Nicholasville, Kentucky 40356 PULL SIDE INSTALLATION - SINGLE DOOR Opening Width Housing Width Y Dim 36" 39" 6.25" 42" 45" 12.25" 48" 51" 18.25" S&G TOUCHLESS ADO.docx REV - 08/2021...
Page 13
[t] 800.826.7652 ■ 859.885.9411 ■ E-mail: (Information Required) ■ One Security Dr. Nicholasville, Kentucky 40356 PULL SIDE INSTALLATION – PAIR OF DOORS Opening Width Housing Width A Dim C Dim 72" 75" 12-7/16" 84" 87" 10-7/8" 96" 99" 24-7/16" 22-7/8" S&G TOUCHLESS ADO.docx REV - 08/2021...
Page 14
(Shown with Double Egress Arm on the right; Push Arm with 80mm spindle on the left) Opening Width Housing Width A Dim C Dim 72" 75" 12-7/16" 84" 87" 10-7/8" 96" 99" 24-7/16" 22-7/8" S&G TOUCHLESS ADO.docx REV - 08/2021...
Page 15
The orientation of the motor assembly will depend on the door handing & application (see below). PUSH APPLICATION (I/O board towards the hinge) Auto Operator Auto Operator Hinge PULL APPLICATION (Motor towards the hinge) Hinge Auto Operator Auto Operator S&G TOUCHLESS ADO.docx REV - 08/2021...
Page 16
5. Secure the motor assembly by tightening all 5 hex bolts. Reconnect the ON-Auto-OFF connector to the I/O board and the molex main power connector. S&G TOUCHLESS ADO.docx REV - 08/2021...
[t] 800.826.7652 ■ 859.885.9411 ■ E-mail: (Information Required) ■ One Security Dr. Nicholasville, Kentucky 40356 STEP 3: INSTALL THE ARM ASSEMBLY - STANDARD APPLICATION NOTE: All operator arms include a standard spindle as shown below. Arm assembly options are detailed on the next three pages. Proceed to Page xx for arm installation instructions. PUSH ARM FOR STANDARD PUSH APPLICATION FOR REVEALS UP TO 8” 5.00 STANDARD 35mm Reveal 4.750 Included w/Push arm .248 1.078 PUSH ARM 2.388 DOOR (OUTSWING) 1.062 S&G TOUCHLESS ADO.docx REV - 08/2021...
Page 18
ARM EXTENSION (for reveal > 8"; sold separately) P/N: AUTO-AEV (CLEAR) P/N: AUTO-AEX (BLACK) PULL ARM FOR STANDARD PULL APPLICATION WITH 0” REVEAL NOTE: FOR REVEALS > 0” BUT LESS THAN ½”, A SPACER (PROVIDED BY INSTALLER) MAY BE INSTALLED BEHIND THE SLIDE TRACK TO ACHIEVE A 0” REVEAL. FOR A PULL APPLICATION WITH A REVEAL GREATER THAN ½”, USE A DOUBLE EGRESS ARM WITH A 20mm SPINDLE. 5.00 SPINDLE 20mm Included 4.75 w/Pull arm 1.375" to 1.5" 2.363 .223 .453 0" Reveal PULL ARM DOOR (INSWING) S&G TOUCHLESS ADO.docx REV - 08/2021...
Page 19
[t] 800.826.7652 ■ 859.885.9411 ■ E-mail: (Information Required) ■ One Security Dr. Nicholasville, Kentucky 40356 80mm (P/N: SP80, sold separately) 50mm (P/N: SP50, sold separately) 35mm (P/N: SP35, sold separately) (included with pull arm) S&G TOUCHLESS ADO.docx REV - 08/2021...
Page 20
[t] 800.826.7652 ■ 859.885.9411 ■ E-mail: (Information Required) ■ One Security Dr. Nicholasville, Kentucky 40356 DOUBLE EGRESS ARM FOR STANDARD DOUBLE EGRESS PAIR OF DOORS, OR FOR A PULL APPLICATION WITH A REVEALGREATER THAN ZERO INCHES NOTE: AN 80mm SPINDLE IS INCLUDED WITH THE DOUBLE EGRESS ARM. THE 80mm SPINDLE SHOULD BE USED FOR DOUBLE EGRESS PAIR OF DOORS. FOR PULL APPLICATIONS WITH REVEALS > 0”, USE A DOUBLE EGRESS ARM WITH A 20mm SPINDLE (SOLD SEPARATELY). 80mm (included with double egress arm) 50mm (P/N: SP50, sold separately) 35mm (P/N: SP35, sold separately) 20mm (P/N: SP20, sold separately) S&G TOUCHLESS ADO.docx REV - 08/2021...
Page 21
• Use the chart below to determine the prescribed length of the secondary arm assembly and note the dimensions. Reveal Hinge Hung X Dim. Center Pivot X Dim. 0" 13" 16" 1" 14" 17" 2" 15" 18" 3" 16" 19" 4" 17" 20" 5" 18" 21" 6" 19" 7" 20" 8" 21" FOR DEEPER REVEAL DISTANCES UP TO 15”, USE ARM EXT. S&G TOUCHLESS ADO.docx REV - 08/2021...
Page 22
Mark a pencil line at the edge of the sleeve where it overlaps the short arm that is connected to the primary arm. This will make it easier when positioning the primary arm for final installation. o After marking the line, remove the primary arm assembly only from the sleeve. S&G TOUCHLESS ADO.docx REV - 08/2021...
Page 23
Center Pivot Doors: Centerline of door shoe at 16" in from inside of pivot jamb o The horizontal centerline of the door shoe will be approximately 2-3/8" below the bottom of the backplate S&G TOUCHLESS ADO.docx REV - 08/2021...
Page 24
Auto Operator • Tighten the spindle adaptor to the operator • Turn & Slide the primary short arm into the sleeve to the pencil marked position. Tighten the hex screws within the sleeve once complete S&G TOUCHLESS ADO.docx REV - 08/2021...
Page 25
7.5" 10.5" 8" • When using the standard 20mm spindle, the center of the track should be approximately 2-1/4” below the operator header. Attach the track with the screws provided. S&G TOUCHLESS ADO.docx REV - 08/2021...
Page 26
When completed, the end caps to the track can be installed. • Once the arm is installed and door is closed, press and hold button SW1 to launch a new setup (see Step 6) S&G TOUCHLESS ADO.docx REV - 08/2021...
• The opening direction is always counter-clockwise rotation when viewed as shown above • Loosen the bolts on the desired stop (do not remove bolts) and move to the desired position • Re-tighten bolts securely and test the door travel stroke S&G TOUCHLESS ADO.docx REV - 08/2021...
Page 28
Do not use the soft stop method if there is anything behind the open door that the door could be repeatedly pushed into from manual openings - such as a glass wall. S&G TOUCHLESS ADO.docx REV - 08/2021...
Page 29
NOTE: IF THE UNIT HAS TWO WHITE WIRES, BOTH WILL CONNECT TOGETHER TO INCOMING NEUTRAL. • DO NOT TURN POWER ON until all remaining wiring has been completed. BLACK: 115 VAC Power WHITE: Neutral GREEN: Ground S&G TOUCHLESS ADO.docx REV - 08/2021...
• The I/O board will not accept an activation until approx. 8 seconds after powering on AND until an initial setup is completed. • Initial setup should be done with all dip switches in the OFF position for PUSH applications, and with DIP #2 ON for pull applications. SETUP BUTTON S&G TOUCHLESS ADO.docx REV - 08/2021...
Page 31
Indicates status of input 14 In active Inactive Inactive Alarm command is active Fire Alarm command inactive Indicates status of input 16 Overhead Presence Command Overhead Presence Command Indicates status of input 17 Active Inactive S&G TOUCHLESS ADO.docx REV - 08/2021...
Page 32
• Go to Step 9. Adjust opening and closing speeds, and door hold open time as necessary. If speeds are changed, a re-learn is not required. • A re-learn is not required following a main power recovery. S&G TOUCHLESS ADO.docx REV - 08/2021...
Page 33
• There are 2 sets of dip switches. A 2-position on the I/O board (DS2), and a 10-position on the adjustment board (DS10). DS1 NOT USED Description For factory use only 3 Seconds (Default) Electric Lock Delay 500 milliseconds 200 milliseconds (Default) S&G TOUCHLESS ADO.docx REV - 08/2021...
Page 34
• ON is with the switch towards the number. Initial setup should be done with all dip switches in the position PUSH applications, and with DIP #2 ON for pull applications. All other dip switches may be set after the initial setup. S&G TOUCHLESS ADO.docx REV - 08/2021...
Page 35
5 seconds to close. Speed & low energy operation via time potentiometers are disabled. potentiometers. (Default) Settings are fixed. Not used for Low Set to OFF for Low Energy S&G TOUCHLESS ADO.docx REV - 08/2021...
Page 36
Disabled assisted closing Closing*** a manual opening following a manual opening 10 FACTORY USE ONLY *** S&G recommends the use of a door-mounted secondary activation device when dip switch 9 is ON - Enabled. S&G TOUCHLESS ADO.docx REV - 08/2021...
Alarm Output Common - Common Alarm Output N.O. output is closed upon closed contact from fire alarm. LED 2 also illuminates. + 24 VDC 1A max. (Total for terminals 9 & 25) Common GND S&G TOUCHLESS ADO.docx REV - 08/2021...
AND amber light DL4 is cleared by pressing the switch next to DL4. • Hold Open time affects the delay following activation from input 10, 11, and 13. • When Dip Switch 5 is ON, the blue speed and time potentiometers are disabled. S&G TOUCHLESS ADO.docx REV - 08/2021...
Ensure there is no binding of the door as it is closing through the • 10 degrees of closing last few degrees of closing. If binding exists (from a tight bottom sweep, for example), correct the condition and then re-launch a new setup. S&G TOUCHLESS ADO.docx REV - 08/2021...
Page 40
• Abnormal noises may come from the operator as you use the door manually • Wear marks may be evident on the body of the operator where the tensioner bolt has slipped • Contact the factory for tensioning instructions. S&G TOUCHLESS ADO.docx REV - 08/2021...
{Shown w/ door fully closed} closes upon full door closed position. Terminal 5: Common for both Door Open & Closed status Terminal 6: Door “Open” status switch: Contact is closed when door is full open. S&G TOUCHLESS ADO.docx REV - 08/2021...
Page 42
• Jumpers must be installed between terminal 8 and 12 & 14 if those inputs are not required for the application. If they are used for the application, they must be connected to a N.C. circuit. S&G TOUCHLESS ADO.docx REV -...
Page 43
WIRELESS PUSH PLATE WITH 24VDC ELECTRIC STRIKE OR MAGLOCK MUST INSTALL MOV! - As close to strike as possible. Fail- Secure Strike 24VDC EMLock® PUSH TO OPEN (N/O) Push SDC Wireless Button Receiver w/ Wireless (Mounted in (COM) Transmitter housing) S&G TOUCHLESS ADO.docx REV - 08/2021...
Page 44
TRIG A TRIG B RELAY A RELAY B Power Transfer Blk (-) Red (+) LR100 Series Latch Retraction Kit PUSH TO OPEN (N/O) SDC Wireless Push Receiver Button (COM) (Mounted in w/ Wireless housing) Transmitter S&G TOUCHLESS ADO.docx REV - 08/2021...
Page 45
SARGENT & GREENLEAF ■ WWW.SARGENTANDGREENLEAF.COM [t] 800.826.7652 ■ 859.885.9411 ■ E-mail: (Information Required) ■ One Security Dr. Nicholasville, Kentucky 40356 LOW ENERGY APPLICATION 4: SIMULTANEOUS PAIRS Not Used S&G TOUCHLESS ADO.docx REV - 08/2021...
Page 46
On-Off-Hold switch located in the header end-cap. One switch will control both doors. • All control adjustments (speed & time delay) must be made independently at each control. • All dip switches at each control must be set independently and must match between controls. S&G TOUCHLESS ADO.docx REV - 08/2021...
The door arm bracket must be through-bolted. o When attaching the header to the hollow metal door frame, ensure there are 5 attaching screws spaced equally apart. They should be #12 sheet metal type screws. S&G TOUCHLESS ADO.docx REV - 08/2021...
Page 48
• Only fire rated hardware shall be used on a fire rated door & frame assembly. • Ensure the operator that is being installed has the proper fire rated label applied to the header. S&G TOUCHLESS ADO.docx REV - 08/2021...
Need help?
Do you have a question about the Touchless ADO and is the answer not in the manual?
Questions and answers