Download Print this page
Celect SAS908XWHB-7-DF1 Manual

Celect SAS908XWHB-7-DF1 Manual

Waterline master control controller

Advertisement

Quick Links

SAS908XWHB-7-DF1 Waterline Master Control Controller
SAS908XWHB-7-DF1 most common residential thermostat and is designed to be used with electric,
gas or oil heating control system.the wireless thermostat application for adjust the room temperature
application.
Power source ....................................2 AA size 1.5V alkaline battery
Wireless frequency band........................868MHZ(FSK)
Wireless transmitter range.......................100m in the open air
Room temperature setting range .............5℃~50℃ or 41℉~123℉
Accuracy.............................................0.5℃ or 1℉
Ambient temperature-operation...............0℃~+50℃(32℉~122℉)
Ambient temperature-transport................-10℃~+60℃(14℉~140℉)
Dimensions.........................................115×90×32mm
 Can be placed anywhere in the home to detect and control the temperature of an area of the user's choice.
Not limited by power control wiring locations.
 Link with the Receiver via RF. Control distance 100M open site.
 Large LCD display
 The screen displays the set temperature and the room temperature also time simultaneously
 Permanent user setting and program setting retention during power loss
 Optional temperature display of Celsius or Fahrenheit scale
 Both Vacation mode and hold duration mode available for comfort and energy saving
 Optional programming Period: 7 individual day or Separate 5-day (weekday) and 1-day/1-day
(Saturday/Sunday) programming with 4 or 6 separate time/temperature periods per day.
 Display temperature recalibrates
 Low battery indication
 Anti-freezing protection
KEYBOARD, DISPLAY AND SWITCH DESCRIOPTION
SPECIFICATION
FEATURE:
1

Advertisement

loading

Summary of Contents for Celect SAS908XWHB-7-DF1

  • Page 1 SAS908XWHB-7-DF1 Waterline Master Control Controller SAS908XWHB-7-DF1 most common residential thermostat and is designed to be used with electric, gas or oil heating control system.the wireless thermostat application for adjust the room temperature application. SPECIFICATION Power source ………………………………2 AA size 1.5V alkaline battery Wireless frequency band……………………868MHZ(FSK)...
  • Page 2: Install The Thermostat

    Button and Functional description: ① Power on/ anti-freezing /off button; ② Time setting button;At starting shortly press ② button enter setting the minute, press add and subtract key, adjust the minute, press ④ button to confirm and exit; then shortly press button enter setting the ②...
  • Page 3: Output Regulation

    Wall installation: Tabletop installation: Error and Alarm function warning flashes on the screen for approximately 30 days when your thermostat runs out of 1) “ ” batteries. Replace the batteries when Low battery warning flashes 2) Room Temp (inside room Sensor) broken or short cut, the thermostat will have “room ERR” display 3) Communication alarm: When the thermostat stops or starts the output, the receiver do not start or not receive some signals that can not return to the thermostat, display will show Er2 OUTPUT REGULATION...
  • Page 4 2. Setting Temp – Room Temp ≥1℃, heating output on (Fast heating or slow heating, see configuration menu 6 items) 3. Room Temp – Setting Temp ≥1℃, heating output off, Configuration setting In standby mode press ③ button under the above three seconds, Through the After button adjustment, 、...
  • Page 5 factory default setting and return to implied parameters setting the first item,shortly press button exit implied parameters setting and return to OFF mode; In standby mode implied parameters display : 3.In boot mode display: A)In program running mode, shortly press button enter off mode;shortly press enter modify the time;shortly press button...
  • Page 6 2. Programming Setting Instruction In programming setting mode, look at the factory preprogrammed times and temperatures shown in the sample schedule. If this program will suit your needs, simply press the ③ button to begin running the factory preset program. If you want to change the preprogrammed time and temperature, follow these steps.
  • Page 7 Monday 6:00 21℃ 8:00 16.5℃ 12:00 21℃ 14:00 16.5℃ 18: 00 21℃ 22: 00 16.5℃ Values Tuesday 6:00 21℃ 8:00 16.5℃ 12:00 21℃ 14:00 16.5℃ 18: 00 21℃ 22: 00 16.5℃ Values Wednesday 6:00 21℃ 8:00 16.5℃ 12:00 21℃ 14:00 16.5℃...
  • Page 8 Table Four(5+1+1 6 Zones programme). ———could revised according to your request Heating Morning Our for work Lunch Noon shift Came back Sleep Mode Get up Monday 6:00 21℃ 8:00 16.5℃ 12:00 21℃ 14:00 16.5℃ 18:00 21℃ 22: 00 16.5℃ Values Tuesday 6:00 21℃...
  • Page 9 Thursday 6:00 21℃ 8:00 16.5℃ 18:00 21℃ 22:00 16.5℃ Values Friday 6:00 21℃ 8:00 16.5℃ 18:00 21℃ 22:00 16.5℃ Values ———could revised according to your request Heating Morning Our for work Came back Sleep Mode Get up 6:00 8:00 21℃ 16.5℃...
  • Page 10: Customer Assistance

    Otherwise, Please replace the product, Then press the last step action to execute. 2) Open SAS908XWHB-7-DF1 backplane Load two batteries (AA) ,Closed the backplane, And check the display and button functions, not normal replacement product, Press re-execute the previous step action.