Evinrude ICON User Manual
Evinrude ICON User Manual

Evinrude ICON User Manual

Concealed side mount remote control

Advertisement

EVINRUDE
REMOTE CONTROL USER'S GUIDE

TABLE OF CONTENTS

Declaration of Conformity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Safety Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
ICON REMOTE CONTROL Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Emergency Stop Lanyard . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Master Power/Key Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Station Select . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Switch Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
START/STOP Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Shift and Throttle Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Control Lever . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
FORWARD Gear . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
REVERSE Gear . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
NEUTRAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
THROTTLE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
NEUTRAL Throttle Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
RPM Adjustment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Trim and Tilt Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Control Lever Trim and Tilt Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Station Protect . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Indicator LED Brightness and Gauge Backlighting . . . . . . . . . . . . . . . . . . . . 12
Control Lever Friction Adjustment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
ICON Network Specifications and Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
ICON Gateway Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
ICON Network Hubs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Accessory Power Relay Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Engine Identity Numbers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Frequently Asked Questions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
ICON Fault Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
ICON System Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Product Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Notes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
®
ICON™ CONCEALED SIDE MOUNT
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ICON and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Evinrude ICON

  • Page 1: Table Of Contents

    Control Lever Friction Adjustment ........12 ICON Network Specifications and Information ......13 Specifications .
  • Page 2: Declaration Of Conformity

    DECLARATION OF CONFORMITY • Application of Council Directives: Directive 94/25/EC as amended by 2003/44/EC – Recreational-Craft This product has been designed to be compliant with the above Directive. Maximum performance, and compliance with the EMC Directive, can only be ensured by cor- rect installation.
  • Page 3: Safety Information

    This User’s Guide contains essential informa- tion to help prevent personal injury and dam- This User’s Guide uses the following signal age to equipment. Use the ICON User’s words identifying important safety messages. Guide in combination with the boat and en- gine operator’s guides.
  • Page 4: Icon Remote Control Features

    ICON REMOTE CONTROL FEATURES The ICON single lever concealed side mount remote control is used in single engine installa- tions. Use the ICON single lever concealed side mount remote control for single station instal- lations. – 007967 Feature Function Control Lever Controls shift and throttle function for outboard.
  • Page 5: Operation

    ® ICON™ C ’ VINRUDE ONCEALED OUNT EMOTE ONTROL UIDE OPERATION Operators should be familiar with nautical orientation. This User’s Guide often identifies outboards, parts or procedures using terms shown in the di- agram below. STARBOARD FORWARD PORT 008002...
  • Page 6: Emergency Stop Lanyard

    Operation Emergency Stop Lanyard WARNING Snap the emergency stop lanyard to a secure place on the operators clothing or life vest – Avoid knocking or pulling clip off the not where it might tear away instead of acti- stop switch during normal boating. vating the stop switch.
  • Page 7: Station Select

    007894 The master power/key switch turns power ON 1. NEUTRAL indicator LED and OFF to the: 008003 • ICON control network • Outboard • NMEA 2000/gauge network • Boat accessories (requires Accessory Pow- er Relay Kit, P/N 765296) In single station installations, the remote con-...
  • Page 8: Switch Panel

    Operation Switch Panel Press and release the STOP symbol of switch to stop the outboard. A switch panel is located at the operator sta- tion. The switch panel contains the START/ STOP switch, a NEUTRAL switch and an RPM switch. –...
  • Page 9: Shift And Throttle Control

    Move the control lever to the forward position. The NETRAL indicator LED turns OFF and the outboard shifts into FORWARD (FWD) gear. 1. NEUTRAL position 008005 1. FORWARD position 008005 Note: The ICON system delays gear changes until engine speeds are below 1500 RPM.
  • Page 10: Throttle

    Operation THROTTLE During normal operation, the Engine Manage- ment Module (EMM) of the outboard limits en- After shifting, move the control handle slowly gine speed to 1200 RPM while in NEUTRAL. in the same direction to increase speed. Return the control lever to the NEUTRAL po- For FORWARD gear, move control lever in a sition and press the N switch to deactivate forward direction to increase speed.
  • Page 11: Trim And Tilt Switch

    Note: “Station Protect” is normally used in dual station applications and this feature lim- its use of control stations. Station Protect must be set up during installation. Dealers must use Evinrude Diagnostics software to reprogram the Engine Management Module (EMM) to turn ON this option. –...
  • Page 12: Indicator Led Brightness And Gauge Backlighting

    Control Lever Friction Adjustment Indicator LED Brightness and CONTROL LEVER FRICTION Gauge Backlighting ADJUSTMENT The RPM switch also allows the operator to Check control lever friction adjustment. When adjust the brightness of indicator LEDs on the properly adjusted, the control lever should control base and the backlighting of the have low friction to allow easy movement in NMEA 2000/I-Command gauges.
  • Page 13: Icon Network Specifications And Information

    The gateway module receives power from the network power cable. When the gateway is Two hubs MUST be installed in the ICON net- powered and receiving data from the network work. See ICON System Diagram on the LED on the gateway module turns ON.
  • Page 14: Accessory Power Relay Kit

    ESM. Accessory Power Relay Kit, P/N 765296, must be used to power boat accessories The first time the ICON system is turned ON, which require switched B+. This kit is used in it automatically checks engine identity num- place of connecting accessories to the “A”...
  • Page 15: Frequently Asked Questions

    Q: How do I make a flashing NEUTRAL indicator LED stop flashing? A: Check emergency stop lanyard is in place. Move control lever to NEUTRAL position. Reset the ICON system by turning the master power/key switch to the OFF position and then back to the RUN position.
  • Page 16: Troubleshooting

    NMEA 2000 buss cable is not Check NMEA 2000 buss cable connected or is damaged. connectors. Check network connections from Gateway module LED Gateway module is not receiving gateway to ICON network hub and buss flashing. data from ICON control network. cable backbone.
  • Page 17: Icon Fault Messages

    Seek assistance to return to harbor. See dealer. RPM reduction, ICON fault 109, Control Hardware Fault see user guide. ICON Shutdown - ICON system shifts into NEUTRAL idle if able. Seek assistance to return to harbor. See dealer. RPM reduction, ICON fault 111, ESM Communication Fault see dealer.
  • Page 19 ® ICON™ C ’ VINRUDE ONCEALED OUNT EMOTE ONTROL UIDE DEVICE DEVICE DEVICE DEVICE DEVICE DEVICE...
  • Page 20: Product Warranty

    BRP US Inc.* ("BRP") warrants its Evinrude®/Johnson® Genuine Parts and accessories ("Prod- uct") sold by authorized Evinrude or Johnson dealers in the fifty United States and Canada from defects in material or workmanship for the period and under the conditions described below. This limited warranty does not apply to Products not bearing the Evinrude or Johnson trademarks that are made by other manufacturers.
  • Page 21 ® ICON™ C ’ VINRUDE ONCEALED OUNT EMOTE ONTROL UIDE SOME JURISDICTIONS DO NOT ALLOW FOR THE DISCLAIMERS, LIMITATIONS OF INCI- DENTAL OR CONSEQUENTIAL DAMAGES, OR OTHER EXCLUSIONS IDENTIFIED ABOVE. AS A RESULT, THEY MAY NOT APPLY TO YOU. THIS WARRANTY GIVES YOU SPECIFIC RIGHTS, AND YOU MAY ALSO HAVE OTHER LEGAL RIGHTS THAT MAY VARY FROM JURIS- DICTION TO JURISDICTION.
  • Page 22: Index

    Fuse 13, 16, 18 Shift Actuator Sensor Fault 17 Shift and Throttle Control 9 ICON Fault Messages 16, 17 Specifications 13 ICON Gateway Module 13, 15, 16, 18 Station Protect 11 ICON Network Hub 13, 18 Station Select 7 ICON Network Specifications and...
  • Page 23: Notes

    ® ICON™ C ’ VINRUDE ONCEALED OUNT EMOTE ONTROL UIDE NOTES...

Table of Contents