Download Print this page

squarespace SMART CELLAR Operation And Maintenance

Smart cellar inverter cooling unit

Advertisement

Quick Links

CONTENTS
1
2
3
SMART CELLAR QUICK REFERENCE GUIDE
4
INDOOR INSTALLATION GUIDE
14
INDOOR LCD AP2 GATEWAY DIAGNOSTICS
15
16
INDOOR AND OUTDOOR ELECTRICAL WIRING DIAGRAM
19
24
REFRIGERATION LINE SET AND CONNECTION INSTRUCTIONS
29
30
34
END
SMART CELLAR INVERTER COOLING UNIT
WWW.AIRSHEPHERD.COM.AU
0
WWW.AIRSHEPHERD.COM.AU

Advertisement

loading
Need help?

Need help?

Do you have a question about the SMART CELLAR and is the answer not in the manual?

Questions and answers

Summary of Contents for squarespace SMART CELLAR

  • Page 1: Table Of Contents

    SMART CELLAR INVERTER COOLING UNIT WWW.AIRSHEPHERD.COM.AU CONTENTS SAFETY WARNINGS AND PRECAUTIONS OPERATION AND MAINTENANCE SMART CELLAR QUICK REFERENCE GUIDE INDOOR INSTALLATION GUIDE INDOOR LCD AP2 GATEWAY DIAGNOSTICS TROUBLESHOOTING INDOOR AND OUTDOOR ELECTRICAL WIRING DIAGRAM OUTDOOR UNIT INSTALLATION REFRIGERATION LINE SET AND CONNECTION INSTRUCTIONS...
  • Page 2: Safety Warnings And Precautions

    ● Only use the SMART CELLAR as instructed in this booklet. These instructions are not intended to cover every possible condition and situation. As with any electrical household appliance, common sense and caution are therefore always recommended for installation,...
  • Page 3: Operation And Maintenance

    Always disconnect power supply when cleaning the SMART CELLAR, to minimise the risk of electric shock, injury or damage to the appliance. ● Never install or operate SMART CELLAR with a damaged supply cord. This must be replaced by the qualified persons to avoid a hazard. ●...
  • Page 4 SMART CELLAR INVERTER COOLING UNIT SMART CELLAR SPECIFICATIONS WWW.AIRSHEPHERD.COM.AU...
  • Page 5 The temperature of the refrigerant circuit will be high, always keep the interconnection cable away from the copper tube. ● The SMART CELLAR is a Class 1 electric appliance. It must be properly earthed using a specialised earthing device installed by a professional, otherwise it may cause electric shock. WWW.AIRSHEPHERD.COM.AU...
  • Page 6 SMART CELLAR INVERTER COOLING UNIT ● The yellow-green wire in SMART CELLAR is the earth wire. The earth wire cannot be used for other purposes. ● The earthing resistance should comply with national and local electrical safety regulations, codes and standards.
  • Page 7 SMART CELLAR INVERTER COOLING UNIT 2. Install the hanger on the indoor unit, as shown in Figure 4. Figure: 4 1. Prior to installation, prepare all piping (refrigerant pipe, drain pipe) and wiring (wired controller, wires between the indoor and outdoor unit) of the indoor unit 2.
  • Page 8 SMART CELLAR INVERTER COOLING UNIT Check Indoor Unit is Level ● Low humidity environment - insure unit is level without fall to drain port, this will keep 3-5mm of condensate in evaporator drip tray.This will increase relative humidity ● Supplied Indoor Installation bag contains one large foam adhesive rectangular strip that can be installed into the base only of the evaporator drip tray to increase humidity level.
  • Page 9 SMART CELLAR INVERTER COOLING UNIT Plenum Return Canvas Return Supply Plenum Supply diffuser Diffuser return air duct duct supply air duct joint louver outlet Figure 8 1. Preinstall the outlet of the round duct on the transition duct and then fix it with self-tapping screws.
  • Page 10 SMART CELLAR INVERTER COOLING UNIT Installation of the Condensate Pipe 1. The condensate pipe should be installed at an angle of 5 - 10° to facilitate the drainage of condensate water from the unit. The condensate pipe should be insulated to minimise condensation (See Figure 13).
  • Page 11 SMART CELLAR INVERTER COOLING UNIT 8. When a single drain pipe is used for multiple devices, the common section of the pipe should be 100mm lower than the drain hole of each device and should be sized appropriately for the total water flow.
  • Page 12 SMART CELLAR INVERTER COOLING UNIT NOTICE: ● Maximum lift of lift pipe (condensate pump) is 1m (1000mm) from base of unit. ● To prevent excessive force on the unit drain outlet, the drain hose connection between the lift pipe and the drain pipe should not be misaligned by more than 75mm (See Figure 17).
  • Page 13 Do not modify the wiring inside the indoor unit. Doing so will void the warranty. ● Communication cable from indoor unit ( N.2 on terminal strip) must be wired to smart cellar gateway module, communication cable from smart cellar gateway terminal (N.2) must be connected to communication cable to outdoor unit terminal N.2...
  • Page 14 SMART CELLAR INVERTER COOLING UNIT CAUTION • SMART CELLAR ultra compact indoor unit and SMART CELLAR inverter outdoor unit must be installed on the same circuit breaker. 1. Remove the cover of the electric box of the indoor unit. 2. Insert the power cable through the rubber ring.
  • Page 15 The use of an independent room humidifier may be required for long term storage for cork bottles. ● Recommended storage temperature range is between 12℃ -18℃ ● Relative humidity range between 50%-75% SMART CELLAR AP2 GATEWAY LCD DIAGNOSTICS ● LCD diagnostic gateway display at indoor unit must be accessible for diagnostics and fault diagnosis. WWW.AIRSHEPHERD.COM.AU...
  • Page 16: Troubleshooting

    Monthly Maintenance a. Cleaning return air filter if required. 1. When the SMART CELLAR ultra compact indoor unit is used in a high dust environment, a minimal restrictive air filter should be installed in the return air line and cleaned often (generally once every 4 weeks with soapy water).
  • Page 17 The installation must be conducted in accordance with local and national wiring regulations, codes and standards. ● Only the power cord with the rated voltage and specified circuit for SMART CELLAR can be used. ● Do not apply excessive force to the power cord.
  • Page 18 SMART CELLAR INVERTER COOLING UNIT Earthing Requirements The SMART CELLAR is classified a Class I appliance and must be earthed. The yellow-green wire is the earth line and cannot be: used for any other purpose, cut off, or fixed by a self-tapping screw.
  • Page 19 SMART CELLAR INVERTER COOLING UNIT ● If the compressor starts running whilst the stop valve is open and the connection pipe is not yet connected, air may enter the unit and cause an increase in system pressure or compressor rupture, which may in turn result in personal injury or property damage.
  • Page 20: Outdoor Unit Installation

    Connection Wire Air Outlet NOTICE: ● The above image is only intended to be a simple diagram of the SMART CELLAR outdoor unit and may not correspond to the appearance of the units that have been purchased. INSTALLATION LOCATION ●...
  • Page 21 SMART CELLAR INVERTER COOLING UNIT UNIT LOCATION The outdoor unit should be installed in a location: ● Where the noise and outflow air emitted by the unit will not affect the neighbourhood ● Where there is sufficient ventilation ● Where the area surrounding the unit is dry and free of moisture ●...
  • Page 22 SMART CELLAR INVERTER COOLING UNIT Outdoor Unit Installation Space Requirements 1. Confirm the desired space meets the requirements for installation as outlined NOTICE: All dimensions are listed in centimetres (cm), unless otherwise specified. 4.2. Fix the Support of the Outdoor Unit 1.
  • Page 23 SMART CELLAR INVERTER COOLING UNIT Screw Requirements by Outdoor Unit Model Model: SMART CELLAR Number of Screws Required 6 Install the Drain Joint 1. Connect the drain joint into the hole in the chassis of the outdoor unit as shown in Figure 4.
  • Page 24 SMART CELLAR INVERTER COOLING UNIT Fix the Outdoor Unit 1. Place the outdoor unit on the support. 2. Fix the foot holes of the outdoor unit with bolts as depicted. Connect the Indoor Unit and Outdoor Unit Pipes 1. Remove the screw on the right handle of the outdoor unit and then remove the handle.
  • Page 25 SMART CELLAR INVERTER COOLING UNIT 2. Remove the screw cap of the value and align the pipe joint with the bell-mouth of the pipe as depicted. 3. Pre-tighten the union nut by hand as shown in Figure 8. Adjusting the Torque Force Hex Nut Diameter (mm) φ6.00...
  • Page 26 SMART CELLAR INVERTER COOLING UNIT 5. The use of thread sealant paste is required for flared union and flare nut threads. ● The use of thread sealant should not be installed on the flare face or mating surface, this will cause contamination in the refrigeration system, this is classed as a non condensable.
  • Page 27 SMART CELLAR INVERTER COOLING UNIT Fixing the Piping 1. Piping should be placed alongside the nearest wall, limiting the amount of bends and also concealing as much as possible. The minimum semi-diameter of bending the pipe is 10cm. 2. If the outdoor unit is higher than the wall hole, a U-shaped curve must be employed before the pipe enters the wall hole to avoid moisture entering the hole.
  • Page 28 SMART CELLAR INVERTER COOLING UNIT 5. Remove the piezometer, open the liquid valve and gas valve completely using a spanner. 6. Tighten the screw caps of the valves and the refrigerant charging vent. 7. Reinstall the handle. Leakage Detection ●...
  • Page 29 SMART CELLAR INVERTER COOLING UNIT ● Are there any obstructions in the air inlet or outlet? ● Has dust caused through installation been removed? ● Are the gas valve and liquid valve of the connection pipe completely open? ● Is the correct additional refrigerant charge been installed? ●...
  • Page 30: Refrigerant Charging

    SMART CELLAR INVERTER COOLING UNIT Additional refrigerant oil and refrigerant charging is required when extending the connection pipe: ● Additional refrigerant oil amount = 5ml of refrigerant oil for every additional 5m of connection pipe (where extended by 10m beyond the standard length) ●...
  • Page 31: Indoor Lcd Ap2 Gateway Error Code List

    SMART CELLAR INVERTER COOLING UNIT INDOOR LCD AP2 GATEWAY ERROR CODE LIST MALFUNCTI DUAL 8 A/C STATUS POSSIBLE CAUSE ON NAME CODE DISPLAY High During cooling and drying Please refer to the malfunction discharge operation, compressor and outdoor analysis (discharge protection, temperature fan stop while indoor fan operates.
  • Page 32 SMART CELLAR INVERTER COOLING UNIT Indoor The unit will stop operation as it The wiring terminal between evaporator reaches the temperature point. indoor evaporator temperature During cooling and drying temperature sensor and sensor is operation, except indoor fan controller is loosened...
  • Page 33 SMART CELLAR INVERTER COOLING UNIT Overload During cooling and drying The Wiring terminal OVC-COMP is protection for operation, the compressor will stop loose. In the normal state the compressor while the indoor fan operates, resistance for the terminal should be during heating operation the less than 1 ohm.
  • Page 34 SMART CELLAR INVERTER COOLING UNIT Voltage of During cooling and drying Measure voltage of position L & N on DC bus bar operation, the compressor will stop wiring board (xt), if the voltage is is too low while the indoor fan operates,...
  • Page 35 SMART CELLAR INVERTER COOLING UNIT SMART CELLAR INVERTER COOLING UNIT Recommendations and advice regarding the use of the products described in this publication are to be taken as a guide only and are given without liability on the part of the company or its employees.