Polaris EPC12-A1 Owner's Manual page 5

Dc inverter monoblock duct type air conditioner
Table of Contents

Advertisement

DC Inverter Monoblock Duct Type Air Conditioner Installation and Operation Manual
● Please disconnect the main power if to put the air conditioner unit out of use for a long period.
● Please do not expose the air conditioner unit directly under corrosive environment with water or
moisture.
● Please do not foot on or place any goods on air conditioner unit.
● After electrical installation, the air conditioner unit shall be energized for electrical leakage test.
(Operating by professional)
● If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a
similarly qualified person in order to avoid a hazard.
● An all-pole disconnection switch having a contact separation of at least 3mm in all poles should
be connected in fixed wiring.
● The appliance shall be installed in accordance with national wiring regulations.
● The temperature of refrigerant circuit will be high, please keep the interconnection cable away
from the copper tube.
2

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the EPC12-A1 and is the answer not in the manual?

This manual is also suitable for:

Epe30-a1Epc30-a1

Table of Contents