Ultrasound detectors ..................10 4.1.4. Bells ........................10 4.1.5. Human activity....................10 4.2. Detection range of the VV600/602Plus ................10 4.2.1. The vault or safe sensitivity test ................. 11 4.3. Planning a vault protection ....................12 4.4. Planning safe, document cabinet and filing cabinet protection ........
Page 4
Cable requirements ......................25 6.2. Wiring the detector into the system ................... 25 6.3. Control and function test....................26 6.4. Trouble shooting........................ 28 The Testsystem.......................... 29 7.1. VT705P..........................29 7.2. Wiring and commissioning ....................29 Planning and Installation manual VV600/VV602Plus...
At the same time it allows for free movement around the protected area without the risk of creating false alarms. The Aritech VV600Plus system has been field proven to be a very effective and reliable solution for safe, vault and atuomatic teller machines protection. It provides protection with the highest security level possible.
VV602Plus. Each VV600/602Plus seismic detector is a fully equipped vibration detector. This means that all necessary processing electronics is incorporated within each VV600/602Plus unit. Each such unit is ready to co-operate with almost any control panel presently available. No intermediate signal processing is necessary, no vulnerable slave microphones are used.
In order to provide the highest level of security, a daily test of the function of all VV600Plus and VV602Plus detectors in a system is required. Therefore, the Aritech VV600Plus System features a full functional test system that may be operated in parallel with the detection system itself. When activated, the test system will test the following important functions the detection system: •...
Remote test transmitter VM651P Moveable mounting kit VM604P Steel plate for tack welding VT610P Hand held test unit VM652P Keyhole protection kit VM602P Recess mounting box VT611P Safe application test sensor VM653P Spacer for keyhole kit Planning and Installation manual VV600/VV602Plus...
If a second pulse is not detected within 180 seconds the counter will be reset. Five consecutive counts trigger the alarm. The sensitivity of this channel is pre-set and is not affected by the sensitivity setting of the integration channel. Planning and Installation manual VV600/VV602Plus...
One potential free normally closed contact, opening in alarm. • One open collector transistor output, going out of conductive mode upon alarm condition. The transistor is being protected against short circuit with a series resistor. Planning and Installation manual VV600/VV602Plus...
3.2. The VV602Plus ATM seismic detector The Aritech VV602Plus detector is a seismic detector capable of detecting vibrations from an attack on an automatic teller machine (ATM) or night safe deposit box to which it is attached, but still disregarding the vibrations created by the normal operation of the protected object.
LANNING INSTRUCTIONS 4.1. Planning limitations Although the Aritech seismic detectors are designed to provide a high level of immunity against nuisance alarm sources, some precautions have to be observed. Below we would like to mention some circumstances to preferably avoid: 4.1.1.
7. Take all irregularities into account when spacing detectors. Additional detectors may be required. The separation between vault door and the frame will require an additional detector on the door to encounter a possible attenuation at this point. Planning and Installation manual VV600/VV602Plus...
Layout plan It is recommended to prepare a plan to define the location of each sensor and other components of the system. A fold out plan will help in doing this. Planning and Installation manual VV600/VV602Plus...
The VM651P and VM652P have the advantage of forcing the staff to handle the alarm installation properly. It prevents the staff forgetting to remove keys or properly closing the safe doors. Planning and Installation manual VV600/VV602Plus...
If you want to mount a detector on a light weight safe we do recommend you to contact Aritech for further information. The VV602Plus can be mounted directly on the surface, with the movable mounting kit VM651P, or the key-hole protection kit VM652P.
Don’t install sensor on cinder block or other unproved masonry surface without contacting Aritech. Don’t mount sensor on rough surfaces, sand all surfaces. Don’t allow test signal transmitter to make contact with mounting plate or sensor on mansonry installaiton. Planning and Installation manual VV600/VV602Plus...
• High speed steel drill, diam. 4.2 mm (for M5 tap). • High speed steel drill, diam. 10 mm. • Tap M4 (to mount VV600Plus on steel surface). • Oil to cool drill and tap. Planning and Installation manual VV600/VV602Plus...
D = Mounting hole for expansion plug or recess mounting box. E = Mounting holes for Securitas 2000. F = Mounting hole for expansion plug to the test transmitter, VT705P. G = Mounting holes for accessories Planning and Installation manual VV600/VV602Plus...
5.4.1. Mounting on concrete In order to surface mount the VV600/602Plus on concrete, a VM600P mounting plate is always required. Please follow the instructions below carefully. Define the exact location of the VV600Plus and hold the VM600P mounting plate to the wall.
Weld the VM604P mounting plate to the surface. First weld the points 1,2,3,4 then weld the seams 5 and 6 on the inside of the two slots, see illustration. Mount the VV600/602Plus detector to the VM604P mounting plate, using the three M4 screws supplied.
7. When the casting is completed mount the VV600Plus detector on the VM600P mounting plate supplied with the VM602P. 8. After completion of the installation and a successful test, mount the cover plate with the enclosed screws. Planning and Installation manual VV600/VV602Plus...
100 Ohm/2 W gives approx. 1,5 W) in the mounting box and drill a small drain hole in the lowest point of the box. This will give a far better result then trying to seal the box with silicone, which will only result in condensation problems. Planning and Installation manual VV600/VV602Plus...
On metal surface mount exactly as the night position plate. On other surfaces than steel suitable screws and expanders have to be selected by the installer. Mount the VV600/602Plus detector on the base plate of the VM651P kit with the three screws supplied.
Mounting holes A are used for the VM652P. Drill/tap mounting holes as described in chapter 5.2. Mount the VV600/602Plus detector on the VM652P cover plate and wire the detector according to the desired system configuration. The micro-switch inside the VM652P should preferably be wired into the detector’s alarm loop to inhibit arming the alarm system if the keyhole...
26 terminal, two of which are used for the tamper switch and one for the screen to the base. There is a plastic strap for strain relief for the cable and flexible conduit. Planning and Installation manual VV600/VV602Plus...
10 cm of cable after the strain relief. Remove the wire insulation with about 1 cm. Wire the terminals according to wiring diagram below. (Illustration A: Form-A relay. and illustration B: Form-C relay) Planning and Installation manual VV600/VV602Plus...
After five blows, the VV600Plus shall alarm. To protect the surface from damage it is advised to use a small aluminium plate between hammer and surface. This test simulates the attack with hammer and chisel and is only valid for VV600Plus. Planning and Installation manual VV600/VV602Plus...
Page 29
Do not forget to set the detector’s sensibility at the right value. Close the lid of the detector and check for closed-loop condition of the tamper-loop. Perform a functional test of both alarm and tamper signals according to panel specifications. Planning and Installation manual VV600/VV602Plus...
ESTSYSTEM 7.1. VT705P The VT705P is a testsystem consisting of a testgenerator inside the VV600/602Plus and a crystal unit which is mounted on the protected object, inside the detector housing. There are two possiblitities for testing: Test disabled (ex-factory setting).