Ebyte E800-DTU User Manual page 11

Hide thumbs Also See for E800-DTU:
Table of Contents

Advertisement

hengdu Ebyte Electronic Technology Co.,Ltd
C
FC
Parameter description
DATA parameter description:
(1)Broadcast data(data is the content to be sent )
Command:01+type+data
Parameter description:type
01: Broadcast mode 1-The message is broadcast to all devices in the entire network
02:Broadcast mode 2-This message is only broadcast to devices that receiving (except sleep mode) is turned on
03:Broadcast mode 3-The message is broadcast to all full-function devices (routers and coordinators)
Example:FC 05 01 02 AA BB CC
Example description: Send HEX data to network broadcast in broadcast mode 2: 0xAA 0xBB 0xCC
(2)Multicast data(data is the content to be sent)
Command:02+ group+data
Parameter description:group
0~99:Multicast number of multicast messages
Example:FC 05 02 01 AA BB CC
Example description: Send HEX data to network group number 1: 0xAA 0xBB 0xCC
(3)Unicast data(data is the content to be sent)
Command:03+ type +addr+data
Parameter description: type (Coordinator in mode 2. This parameter is invalid and can be set to any value)
01:Transparent transmission mode (without carrying information)
02:Short address mode (carrying information is short address)
03:MAC address mode (carrying information is MAC address)
Parameter description:addr:Network short address
Copyright ©2012–2019,
Chengdu Ebyte Electronic Technology Co.,Ltd
LEN
Effective unicast address 0x0000—0xFFF8)