1. Ââåäåíèå 1. Introduction 1.1 Îáùåå 1.1 General remarks Îñóøèòåëü îõëàæäåííîãî ñæàòîãî âîçäóõà, îïèñàííûé â ýòîé The refrigerated compressed air dryer documented in these èíñòðóêöèè ïî ýêñïëóàòàöèè, îòâå÷àåò âñåì òðåáîâàíèÿì operating instructions has all requirements that can be expected ñîâðåìåííîãî óñòðîéñòâà. from a modern device.
2. Ïðàâèëà áåçîïàñíîñòè, 2. Safety rules, ïðåäîñòåðåæåíèÿ warnings 2.1 Èñïîëüçîâàíèå îñóøèòåëÿ 2.1 Use of dryer Attention ! Ïðåäóïðåæäåíèå ! • The dryer/system must only be used for the purpose as • Îñóøèòåëü/ñèñòåìà äîëæåí èñïîëüçîâàòüñÿ òîëüêî ïî designated in the operating instructions and only in íàçíà÷åíèþ, óêàçàííîìó...
Page 6
2. Ïðàâèëà áåçîïàñíîñòè, 2. Safety rules, ïðåäîñòåðåæåíèÿ warnings 2.3 Ïðåäóïðåæäåíèå áåçîïàñíîñòè 2.3 Security-Warnings Ïðåäóïðåæäåíèå! Warning! Â ñîñòàâ îñóøèòåëÿ âõîäÿò êîìïîíåíòû, íàõîäÿùèåñÿ ïîä The dryer contains components under high pressure. âûñîêèì äàâëåíèåì. Before starting any service work turn off compressed air supply Ïåðåä...
4. Òðàíñïîðòèðîâêà, äîñòàâêà, 4. Transport, delivery, Îñìîòð ïîñòóïàþùåãî òîâàðà Checking of goods received 4.1 Òðàíñïîðòèðîâêà 4.1 Transport Îñóøèòåëü îõëàæäåííîãî ñæàòîãî âîçäóõà íè â êîåì ñëó÷àå íå The refrigeration compressed air dryer must by no means be lifted äîëæåí ïîäíèìàòüñÿ ñ âõîäíûì èëè âûõîäíûì ñîåäèíåíèåì at the compressed air inlet- or outlet connections.
Page 9
5. Óñòàíîâêà è ñáîðêà 5. Installation and mounting 5.1 Ìåñòî óñòàíîâêè 5.1 Location of Installation õîëîäèëüíûé îñóøèòåëü ñæàòîãî âîçäóõà äîëæåí áûòü óñòàíîâëåí The refrigeration compressed air dryer should be installed in a dry â ñóõîì ïîìåùåíèè. Äëÿ îáñëóæèâàíèÿ óñòðîéñòâà íåîáõîäèìî room indoors.
Page 10
5. Óñòàíîâêà è ñáîðêà 5. Installation and mounting 5.5 Óäàëåíèå êîíäåíñàòà 5.5 Condensate drain Äëÿ óäàëåíèÿ êîíäåíñàòà ïðåäóñìîòðåíî îäíî ñîåäèíåíèå: For the condensate drain one connection each is provided: • • Àâòîìàòè÷åñêîå óäàëåíèå êîíäåíñàòà â ïðîöåññå ðàáîòû. Automatic drain during operation. The sizing of the connections please see in chapter 10.
6. Ïåðâîíà÷àëüíûé çàïóñê 6. Initial start-up Ôóíêöèîíèðîâàíèå Operation (âêëþ÷åíèå, (switching on, switching off, âûêëþ÷åíèå, ýëåìåíòû óïðàâëåíèÿ) controls) 6.1 Ïðåäâàðèòåëüíûå óñëîâèÿ 6.1 Preconditions õîëîäèëüíûé îñóøèòåëü ñæàòîãî âîçäóõà ãîòîâ ê ðàáîòå â ñëó÷àå, åñëè: The refrigerated compressed air-dryer is ready for operation when: •...
Page 12
6. Ïåðâîíà÷àëüíûé çàïóñê 6. Initial start-up Ôóíêöèîíèðîâàíèå Operation (âêëþ÷åíèå, (switching on, switching off, âûêëþ÷åíèå, ýëåìåíòû óïðàâëåíèÿ) controls) 6.3 Ôóíêöèîíèðîâàíèå 6.3 Operation • • Èíäèêàòîð âëàæíîñòè â êðàñíîé çîíå ïðèáëèçèòåëüíî 15 The dewpoint indicator are in the red area for approximately ìèíóò...
Page 13
6. Ïåðâîíà÷àëüíûé çàïóñê 6. Initial start-up Ôóíêöèîíèðîâàíèå Operation (âêëþ÷åíèå, (switching on, switching off, âûêëþ÷åíèå, ýëåìåíòû óïðàâëåíèÿ) controls) RFD 315-1000 RFD 315-1000 Íàñòðîéêà ñâåòîäèîäà îòîáðàæåíèÿ òî÷êè ðîñû è òàéìåðà LED´s „Dewoint indication“ and Timer drain setting: îòâîäà êîíäåíñàòà: In case of an sensor-break od a defective sensor line all LED´s are Â...
Page 14
7. Îïèñàíèå ðàáîòû 7. Description of operation  îñóøèòåëå îõëàæäåííîãî ñæàòîãî âîçäóõà òåïëàÿ âëàãà, In the refrigeration compressed air dryer warm, moisture saturated íàñûùåííàÿ ñæàòûì âîçäóõîì, îõëàæäàåòñÿ äî +3°C. compressed air is cooled down to +3°C. Ïåðâûé ýòàï — ýòî ïðåäâàðèòåëüíîå îõëàæäåíèå ïîñòóïàþùåãî The first step is the pre-cooling of the inlet air flow by heat exchange âîçäóøíîãî...
8. Òåõíè÷åñêîå îáñëóæèâàíèå 8. Servicing and maintenance Remark! Ïðèìå÷àíèå! Êîìïîíåíòû â êðóãëûõ ñêîáêàõ (íàïðèìåð. A103) The component specified in parentheses (e.g. A103) îòíîñÿòñÿ ê ïðèíöèïèàëüíîé ñõåìå R&I. refer to the R&I schematic diagram. Ñìîòðèòå òàêæå ðàçäåë 13 «×åðòåæ â ìàñøòàáå». Please see also section 13.
10. Òåõíè÷åñêèå äàííûå 10. Technical data Ñïåöèôèêàöèÿ ñîãëàñíî DIN ISO 7183 Ãëàâà A Specification according to DIN ISO 7183 Option A Ïðèìå÷àíèå! Remark! Èíôîðìàöèÿ, îòìå÷åííàÿ ñèìâîëîì ìîæåò Should any data change which is marked with a * all other èçìåíÿòüñÿ, äðóãàÿ èíôîðìàöèÿ ýòîãî ðàçäåëà òàêæå data in that section may also change.
Page 19
10. Òåõíè÷åñêèå äàííûå 10. Technical data Ñïåöèôèêàöèÿ ñîãëàñíî DIN ISO 7183 Ãëàâà A Specification according to DIN ISO 7183 Option A Ïðèìå÷àíèå! Remark! Èíôîðìàöèÿ, îòìå÷åííàÿ ñèìâîëîì ìîæåò Should any data change which is marked with a * all other èçìåíÿòüñÿ, äðóãàÿ èíôîðìàöèÿ ýòîãî ðàçäåëà òàêæå data in that section may also change.
Page 20
11. Ñòðóêòóðíàÿ ñõåìà 11. P&I-Diagram - 20 - t l l...
Page 21
11. Ñòðóêòóðíàÿ ñõåìà 11. P&I-Diagram - 21 - t l l...
Page 22
11. Ñòðóêòóðíàÿ ñõåìà 11. P&I-Diagram - 22 - t l l...
Page 23
Ïîëîæåíèå íà Çàï÷àñòü Îïèñàíèå Íîìåð äåòàëè. ñòðóêòóðíîé ñõåìå & Ñïóñê êîíäåíñàòà + Òàéìåð Òàéìåð H115 Îòäåëèòåëü âëàãè Îòäåëèòåëü Îñóøèòåëü ôèëüòðà t l i Õîëîäèëüíûé êîìïðåññîð Ëîïàñòü âåíòèëÿòîðà Äâèãàòåëü âåíòèëÿòîðà êàðòåðà Pàñøèðèòåëüíûè êëàïàí l l i Äàò÷èê äàâëåíèÿ âåíòèëÿòîðà Äàò÷èê âûñîêîãî äàâëåíèÿ Äàò÷èê...
Page 24
12. Ñõåìà ýëåêòðè÷åñêèõ 12. Wiring Diagram ñîåäèíåíèé - 24 - t l l...
Page 25
12. Ñõåìà ýëåêòðè÷åñêèõ 12. Wiring Diagram ñîåäèíåíèé - 25 - t l l...
Page 26
12. Ñõåìà ýëåêòðè÷åñêèõ 12. Wiring Diagram ñîåäèíåíèé - 26 - t l l...