JP AG Series Manual

JP AG Series Manual

Advertisement

Quick Links

JP FLUID CONTROL
Torque 50Nm
Open/Close 13s
ISO 5211 F03/F05/F07
Manual override
Position indicator
Position feedback
The AG-series is a range of
high-quality quarterturn actuators
to control the position of valves
with an ISO 5211 flange of type
F03, F05 and F07. The actuator
can deliver 50Nm in a fast and
smooth operation. The dome
indicator provides a clear visual
inspection of the valve position.
The actuator features a manual
override and 2 auxiliary limit
switches for position feedback
Model
Response time
Voltage
Utility frequency
Torque (Max.)
Current (Max.)
Current (Nom.)
Resolution
Housing material
Seal material
Ambient temperature range
ISO 5211 flange
Duty cycle
Properties
AG-5 series actuator
.
Figure 1. AG-5 Actuator.
AG-550-A
13s
100-230V AC ±10%
50/60Hz
50Nm
0.45A
0.13A
0.6°
Powder coated aluminum
NBR
-10°C to max. 50°C
F03, F05 and F07. 9, 10 and 12mm
thread depth respectively
14 x 14 Star connection
IP67 weather proof rating for housing
Manual override lever for safety-control
Cable entry: 2 x ½" PF
Two auxiliary limit switches for position feedback
101,6 x 120,6 x 128,6 mm L x W x H
www.jpfluidcontrol.com
AG-5 series
Electric actuator
AG-550-B
13s
24 AC/DC ±10% (AC/DC automatically
detected)
50/60Hz
50Nm
1.2A
0.25A
0.6°
Powder coated aluminum
NBR
-10°C to max. 50°C
F03, F05 and F07. 9, 10 and 12mm thread
depth respectively
S2 30Min
1W space heater
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AG Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for JP AG Series

  • Page 1 AG-5 series JP FLUID CONTROL Electric actuator • Torque 50Nm • Open/Close 13s • ISO 5211 F03/F05/F07 • Manual override • Position indicator • Position feedback The AG-series is a range of high-quality quarterturn actuators to control the position of valves with an ISO 5211 flange of type F03, F05 and F07.
  • Page 2: Safety Instructions

    AG-5 series JP FLUID CONTROL Electric actuator Safety Instructions General Safety Instructions Please read the safety instructions carefully before installation, use or maintenance. • The actuator only complies protection class IP67 (according to IEC 60529), if the device is properly connected.
  • Page 3: Working Conditions

    AG-5 series JP FLUID CONTROL Electric actuator Identification The following figure shows an example of the type plate of the actuator. Observe the specifications and the connection diagram before using the product. Components Figure 2: Components of the AG-5-Series Actuator.
  • Page 4 AG-5 series JP FLUID CONTROL Electric actuator Step-by-step installation guide Do not use sharp objects while opening the box. Make sure the actuator is disconnected from any electricity before following the installation guide. Carefully open and unpack the box. Loosen the four Captive Bolts of the Terminal Block chamber (Figure 3) and the four captive bolts of the housing cover (Figure 4).
  • Page 5: Electrical Wiring

    AG-5 series JP FLUID CONTROL Electric actuator Electrical wiring Figure 5: Wiring diagram (3 point connection) for the AG-550 models The minimally required wiring for operation is shown in the green box. AG – 550 – A (100-240VAC): Connect terminal 2 to the power supply, connecting terminal 4 to the power supply closes the actuator, connecting terminal 5 to the power supply opens the actuator.
  • Page 6 AG-5 series JP FLUID CONTROL Electric actuator Feedback (optional) Always apply a load (max. 5A) in the feedback circuit to prevent permanent damage. Always apply the correct polarity/phasing. The limit switches share a common source, do not use different power supplies on both limit switches at the same time.
  • Page 7: Actuator Setting And Configuration

    AG-5 series JP FLUID CONTROL Electric actuator Actuator Setting and Configuration Manual override Always disconnect the power supply before using the manual override. Do not use excessive force when shifting the lever and lever wheel to prevent damage. Shift the lever on the bottom of the actuator from “auto” to “manual” to set the actuator to manual override, a small “wiggle”...
  • Page 8: Limit Switch Adjustment

    This manual can be downloaded from www.jpfluidcontrol.com. Modifications reserved. This document has been prepared with great care. JP Fluid Control assumes no responsibility for any errors that may appear in this document. No rights can be derived from this document.

This manual is also suitable for:

Ag-5 seriesAg-550-aAg-550-b

Table of Contents