Page 1
Refer to Service Manual RS6200003 for installation, op- numbers listed in this manual. eration, and troubleshooting information. • All safety information must be followed as provided in MODEL the Service Manual. BBA24A2A P1206401C • Refer to the appropriate Parts Catalog for part number BBA36A2A P1206402C BBA48A2A P1206403C information.
Page 2
PRODUCT IDENTIFICATION The model and manufacturing number are used for positive identification of component parts used in manufacturing. Please use these numbers when requesting service or parts information. Product Type Design Series B: Blower Unit A: First Series Voltage System Type 2: 230 V-1-60 B: Multi-position Factory Heat...
Page 3
PRODUCT DESIGN BBA blower cabinets are designed as a two-piece blower coil. The BBA blower section can be attached to a CCA_FC_, CHA_TC_, or CHF_TC_ cased evaporator coil. This two piece arrangement allows for a variety of mix-matching possibili- ties providing greater flexibility. The BBA blower cabinets can be positioned for upflow, counterflow, horizontal right or horizontal left operation.
Page 4
21 1/8 "W" Dimensions, inches (mm) Shipping Physical Information Weight Blower Wheel Blower Motor MODEL lbs.(kg) (D x W) (HP) BBA24A2A 9 x 7 (28.6) 16 - 1/2 (419) (381) (381) BBA36A2A 22 - 1/4 10 x 7 (30.8) (565)
Page 6
WIRING DIAGRAMS BBA(24-60)A2A TO AVOID PERSONAL INJURY OR DEATH DUE TO ELECTRICAL WARNING SHOCK, DISCONNECT THE POWER BEFORE SERVICING. Wiring is subject to change, always refer to the wiring diagram on the unit for the most up-to-date wiring. 6 Rev. 1...
Page 7
WIRING DIAGRAMS BBA w/ DSK02A TO AVOID PERSONAL INJURY OR DEATH DUE TO ELECTRICAL WARNING SHOCK, DISCONNECT THE POWER BEFORE SERVICING. Wiring is subject to change, always refer to the wiring diagram on the unit for the most up-to-date wiring. 7 Rev.
Page 8
WIRING DIAGRAMS TO AVOID PERSONAL INJURY OR DEATH DUE TO ELECTRICAL WARNING SHOCK, DISCONNECT THE POWER BEFORE SERVICING. RH-HEAT PUMP WITH INDOOR BLOWER COIL WITH APPROVED THERMOSTATS* With Outdoor Thermostat - ATK Controlling ALL Electric Heat Morning Warmup Could be Slow - 4.8 to 28.8KW ROOM THERMOSTAT (6 wires)
Page 9
WIRING DIAGRAMS BBA w/ EHK05B/C TO AVOID PERSONAL INJURY OR DEATH DUE TO ELECTRICAL WARNING SHOCK, DISCONNECT THE POWER BEFORE SERVICING. Wiring is subject to change, always refer to the wiring diagram on the unit for the most up-to-date wiring. 9 Rev.
Page 10
WIRING DIAGRAMS BBA w/ EHK07/10B/C TO AVOID PERSONAL INJURY OR DEATH DUE TO ELECTRICAL WARNING SHOCK, DISCONNECT THE POWER BEFORE SERVICING. Wiring is subject to change, always refer to the wiring diagram on the unit for the most up-to-date wiring. 10 Rev.
Page 11
WIRING DIAGRAMS BBA w/ EHK15B/C TO AVOID PERSONAL INJURY OR DEATH DUE TO ELECTRICAL WARNING SHOCK, DISCONNECT THE POWER BEFORE SERVICING. Wiring is subject to change, always refer to the wiring diagram on the unit for the most up-to-date wiring. 11 Rev.
Page 12
WIRING DIAGRAMS BBA w/ EHK20B/C TO AVOID PERSONAL INJURY OR DEATH DUE TO ELECTRICAL WARNING SHOCK, DISCONNECT THE POWER BEFORE SERVICING. Wiring is subject to change, always refer to the wiring diagram on the unit for the most up-to-date wiring. 12 Rev.
Page 13
WIRING DIAGRAMS BBA w/ EHK25B/C TO AVOID PERSONAL INJURY OR DEATH DUE TO ELECTRICAL WARNING SHOCK, DISCONNECT THE POWER BEFORE SERVICING. Wiring is subject to change, always refer to the wiring diagram on the unit for the most up-to-date wiring. 13 Rev.
Page 14
BBA MODELS ONLY WARNING: DISCONNECT POWER BEFORE THERMISTOR SERVICING. BK-L2 RD-L1 RD-L3 BK-L4 TRANSFORMER RD-L5 BK-L2 BK-L6 RD-L1 RD-L5 BK-L6 WN WN WN WN WN WN IDLE UNUSED FIELD CONNECT 208/240 10 VAC LED FLASH CODE MODE LED ON TIME LED OFF TIME NORMAL OPERATION 1/2 SECOND ON...
Page 15
WIRING DIAGRAMS BBA w/ ECB05B/C TO AVOID PERSONAL INJURY OR DEATH DUE TO ELECTRICAL WARNING SHOCK, DISCONNECT THE POWER BEFORE SERVICING. Wiring is subject to change, always refer to the wiring diagram on the unit for the most up-to-date wiring. 15 Rev.
Page 16
WIRING DIAGRAMS BBA w/ ECB07/10B/C TO AVOID PERSONAL INJURY OR DEATH DUE TO ELECTRICAL WARNING SHOCK, DISCONNECT THE POWER BEFORE SERVICING. Wiring is subject to change, always refer to the wiring diagram on the unit for the most up-to-date wiring. 16 Rev.
Page 17
BBA MODELS ONLY THERMISTOR WARNING: DISCONNECT POWER BEFORE SERVICING. BK-L2 RD-L1 BK-L2 RD-L1 TRANSFORMER CIRCUIT BREAKERS IDLE FIELD CONNECT FIELD CONNECT 208/240 1Ø VAC 208/240 1Ø VAC W/ SPK02A INSTALLED UNUSED LED FLASH CODE MODE LED OFF TIME LED ON TIME NORMAL OPERATION 1/2 SECOND OFF 1/2 SECOND ON...
Page 18
BBA MODELS ONLY THERMISTOR WARNING: DISCONNECT POWER BEFORE SERVICING. BK-L2 RD-L3 RD-L1 BK-L2 BK-L4 RD-L1 TRANSFORMER CIRCUIT BREAKERS IDLE FIELD CONNECT FIELD CONNECT 208/240 1Ø VAC 208/240 1Ø VAC UNUSED W/ SPK02A INSTALLED LED FLASH CODE MODE LED OFF TIME LED ON TIME NORMAL OPERATION 1/2 SECOND OFF...
Page 19
BBA MODELS ONLY WARNING: DISCONNECT POWER BEFORE THERMISTOR SERVICING. BK-L2 RD-L1 RD-L3 BK-L4 TRANSFORMER RD-L5 BK-L2 BK-L6 RD-L1 CIRCUIT BREAKERS IDLE UNUSED FIELD CONNECT FIELD CONNECT 208/240 1Ø VAC 208/240 1Ø VAC W/ SPK03A INSTALLED LED FLASH CODE MODE LED ON TIME LED OFF TIME NORMAL OPERATION 1/2 SECOND ON...
Page 20
BBA MODELS ONLY WARNING: DISCONNECT POWER BEFORE THERMISTOR SERVICING. BK-L2 RD-L1 RD-L3 BK-L4 TRANSFORMER RD-L5 BK-L2 BK-L6 RD-L1 RD-L5 BK-L6 CIRCUIT BREAKERS IDLE UNUSED FIELD CONNECT FIELD CONNECT 208/240 1Ø VAC 208/240 1Ø VAC W/ SPK03A INSTALLED LED FLASH CODE MODE LED ON TIME LED OFF TIME...