Do you have a question about the Braemar XE71-42G and is the answer not in the manual?
Questions and answers
Summary of Contents for Seeley Braemar XE71-42G
Page 1
OWNER’S MANUAL WIRED CONTROLLER 08:30 10/06/2014 AUTO COOL MENU ON/OFF MENU/OK MODE SWING (English) (KDHV)
Page 2
IMPORTANT As with any product that has moving parts or is subject to wear and tear, it is that you maintain your air conditioner and have it regularly VERY IMPORTANT serviced. Accordingly, it is a condition of warranty cover for your air conditioner that you comply with all of the maintenance and service requirements set out in this Manual.
INTRODUCTION & SAFETY Congratulations on purchasing a new when the Braemar Air Conditioning Unit Braemar Air Conditioner! is used. Note: the manufacturer recommends that low level return air grilles Please keep this Manual and the are installed. Warranty Booklet in a safe place, along with the original purchase IMPORTANT! documents, plus all relevant...
6. Before operating the air conditioner, please read this manual carefully and keep it in a safe place for future reference. SEELEY INTERNATIONAL – OWNER’S MANUAL...
OPERATION cont. LCD ICONS Display Definition Display Definition Fresh air Function Fan Speed Health Function Cooling Mode Time On Status Filter Reminder Sleep Function Lock Setting 08:30 Holiday Function Clock Quiet Function Dry Mode I-Demand Function Fan Mode Memory Function Heating Mode DRED Function Auto Mode...
> (3) Set parameter (1) Enter menu MENU/OK page (2) Confirm setting Set auto, cooling, dry, fan and heating MODE modes for indoor unit. For use with the Remote wireless wall Receiver controller (optional) SEELEY INTERNATIONAL – OWNER’S MANUAL...
Page 8
OPERATION cont. ON / OFF MODE SETTING Press the On/Off button to turn the unit Under the ON state of the unit, press on or off. the Mode button to switch the operation modes as the sequence shown below. 08:30 10/06/2014 MENU ON/OFF...
08:30 10/06/2014 MENU/OK SWING MODE COOL MENU Pressing ∧ or ∨ continuously, temperature will ON/OFF 08:30 10/06/2014 be increased or MENU/OK decreased by 1°C SWING MODE every 0.5s. AUTO COOL MENU ON/OFF MENU/OK SWING MODE SEELEY INTERNATIONAL – OWNER’S MANUAL...
OPERATION cont. UP / DOWN SWING SETTING LEFT / RIGHT SWING SETTING Under the ON state of the unit, press the Under the ON state of the unit, press the SWING button to select the “Up and Down SWING button to select the “Left and Right Swing”...
MENU symbol. Press < or > button to select specific SEARCH TIMER CLOCK FUNCTION function item. FUNCTION FRESH AIR LOCK SLEEP MENU HEALTH IDEMAND HOLIDAY MEMORY ON/OFF MENU MENU/OK SWING MODE ON/OFF MENU/OK SWING MODE SEELEY INTERNATIONAL – OWNER’S MANUAL...
OPERATION cont. FRESH AIR FUNCTION FRESH AIR FUNCTION cont. This is used to adjust the fresh air Press ∧ or ∨ button to select volume indoors to improve air quality. fresh air function. FUNCTION FRESH AIR SLEEP Note: HEALTH IDEMAND 1.
- In fan or auto mode, sleep function is not available. - Sleep function will be canceled when turning off the unit or switching modes. Press the MENU/OK button to confirm. FUNCTION FRESH AIR SLEEP HEALTH IDEMAND HOLIDAY MEMORY MENU ON/OFF MENU/OK SWING MODE SEELEY INTERNATIONAL – OWNER’S MANUAL...
OPERATION cont. HEALTH FUNCTION I-DEMAND FUNCTION Generate negative ions to ensure the When the unit is first turned on in COOL health. During operation of indoor fan, set or HEAT modes, set I-Demand to quickly health function by wired wall controller. reach the SET temperature.
ON/OFF sleep function will be valid, and vice versa. MENU/OK SWING MODE Press the MENU/OK button to confirm. FUNCTION FRESH AIR SLEEP HEALTH IDEMAND HOLIDAY MEMORY MENU ON/OFF MENU/OK SWING MODE SEELEY INTERNATIONAL – OWNER’S MANUAL...
OPERATION cont. MEMORY FUNCTION SAVE FUNCTION After power recovery, the unit will be turned Air conditioner operates within a smaller on automatically according to memory temperature range to conserve energy. content. Mode, up & down swing, light, set temperature, set fan speed, general timer. Press ∧...
FUNCTION HEALTH IDEMAND HOLIDAY MEMORY SAVE AUXILIARY HEATING MENU ON/OFF MENU/OK MODE SWING Press the MENU/OK button to confirm. FUNCTION HEALTH IDEMAND HOLIDAY MEMORY SAVE AUXILIARY HEATING MENU ON/OFF MENU/OK MODE SWING SEELEY INTERNATIONAL – OWNER’S MANUAL...
OPERATION cont. DRY FUNCTION DRY FUNCTION cont. The dry function can be used in Press ∧ or ∨ button to select COOL or DRY modes, to continue operation dry function. FUNCTION of the indoor fan for an additional IDEMAND HOLIDAY 2 minutes after the power is turned off (so MEMORY SAVE...
FUNCTION HOLIDAY MEMORY SAVE AUXILIARY HEATING QUIET MENU ON/OFF MENU/OK SWING MODE Press the MENU/OK button to confirm. FUNCTION HOLIDAY MEMORY SAVE AUXILIARY HEATING QUIET MENU ON/OFF MENU/OK SWING MODE SEELEY INTERNATIONAL – OWNER’S MANUAL...
OPERATION cont. FILTER CLEAN REMINDER FILTER CLEAN REMINDER cont. After entering user This function is used to remind you to clean function page, press the filter when the unit’s own operating time ∧ or ∨ button to FUNCTION select filter clean is reach your setting.
Page 21
FILTER CLEAN setting. POLLUTION LEVEL ACCUMULATING TIME 500 HOURS MENU ON/OFF MENU/OK MODE SWING Press < or > button to set required time. FILTER CLEAN POLLUTION LEVEL ACCUMULATING TIME 500 HOURS MENU ON/OFF MENU/OK SWING MODE SEELEY INTERNATIONAL – OWNER’S MANUAL...
OPERATION cont. FAHRENHEIT SETTING LOW TEMPERATURE DRYING This function is only available in dry mode. The temperature display can be toggled between Centigrade and Fahrenheit scales. When low-temperature drying function is on, the displayed set temperature in dry mode is 12 ºC (54 ºF ). This function will Press ∧...
OPERATION cont. LANGUAGE FUNCTION SETBACK FUNCTION Select the preferred language. Press < or > button Press ∧ or ∨ to adjust the limit button to select the temperature value. language function. FUNCTION SETBACK FILTER CLEAN FAHRENHEIT UPPER LIMIT 27 C LOW TEMPERATURE WIFI 18 C...
UNIT STATUS DEFROST Press BACK button AUXILIARY HEAT 200DAY to return to the last CLEANING DUE IN 24 C INDOOR TEMPERATURE page. 24 C OUTDOOR TEMPERATURE RETURN ON/OFF MENU/OK SWING MODE SEELEY INTERNATIONAL – OWNER’S MANUAL...
OPERATION cont. TIMER FUNCTION CURRENT ERROR VIEW cont. The wired controller is capable of setting 5 Press ∧ or ∨ types of timers. button to select error information. SEARCH UNIT STATUS 1. One time clock timer ERROR INFORMATION 2. Daily timer 3.
SCH TIME OnOFF COOL HEAT 07:00 26 C 26 C 26 C 26 C 08:00 26 C 26 C 10:00 11:00 26 C 26 C 26 C 26 C 07:00 MENU ON/OFF MENU/OK MODE SWING SEELEY INTERNATIONAL – OWNER’S MANUAL...
OPERATION cont. WEEKLY TIMER WEEKLY TIMER cont. The user can set the everyday timer content for a week. In each day, 8 segments can be set for the timer. The unit will execute Press the ∧ or ∨ corresponding timer settings in a week. button to adjust the content.
ON/OFF MENU/OK After entering timer off setting page, SWING MODE press ∧ or ∨ TIMER ON button to increase or decrease the HOURS ON timer by 0.5 hours. MENU ON/OFF MENU/OK SWING MODE SEELEY INTERNATIONAL – OWNER’S MANUAL...
OPERATION cont. COUNT DOWN TIMER cont. TIME FORMAT SETTING The time format can be set to either 12 hour or 24 h Press BACK button to return to the last Press the MENU page. TIMER OFF button to enter the functions setting.
Press < or > button to select settings time CLOCK setting items hour, minute, TIME : : 05 year month, day. DATE : 2020/08/20 Press ∧ or ∨ MENU button to set the value. ON/OFF MENU/OK SWING MODE SEELEY INTERNATIONAL – OWNER’S MANUAL...
OPERATION cont. LOCK SETTING The lock setting can lock functions, Mode, temperature, fan speed. After locking the item cannot be set through the controller buttons. NOTE: If the keys are locked, all keys cannot be operated after returning to the previous screen.
About unit view Low temperature dry function Unit ON/OFF lock WiFi function Mode setting lock Setback function Temperature lock Function lock menu Independent swing function Fan speed setting lock Panel lifting function Key lock language selection SEELEY INTERNATIONAL – OWNER’S MANUAL...
Page 34
MENU When an error occurs, please immediately ON/OFF shut down the unit and contact your MENU/OK Seeley approved service agent. MODE SWING A typical error message is shown over - “E1” means the high pressure protection. WIRED CONTROLLER - KDHV Series Inverter Ducted...
ODU jumper cap error DC fan error Phase-loss and anti-phase protection ODU error, for specific error please see Driver out-of-step protection the status of ODU indicator PFC protection Emergency stop Startup failure Compressor stall protection Compressor phase-sequence protection SEELEY INTERNATIONAL – OWNER’S MANUAL...
MAINTENANCE & SERVICE with other debris that may build up AIR FILTER over time, namely, leaves and the like. It is important to check and clean the air filter as per the Maintenance Schedule below. A dirty air filter will not REFRIGERANT allow the correct amount of clean air to pass through your air conditioner,...
Braemar Ducted Inverter Air Conditioning Unit as per the items and frequency set out in the Schedule, and as indicated elsewhere in this Manual. SEELEY INTERNATIONAL – OWNER’S MANUAL...
MAIN COMPONENTS OPERATION TIPS OPERATION TIPS The following events may occur during normal operation: The following events may occur during normal operation: 1. Protection of the air conditioner. INDOOR UNIT 1. Protection of the air conditioner. Compressor protection Compressor protection •...
Probable Cause Remedy LCD ICONS Problem Probable Cause Remedy Seeley International strives for continuous product improvements, therefore specifications are subject to change 1.1 Wait for power to resume. 1. The air conditioner 1.1 Power failure. Icons Introduction 1. The air conditioner 1.1 Power failure.
Page 40
It is the policy of Seeley International to introduce continuous product improvements. Accordingly, specifications are subject to change without notice. Please consult with your dealer to confirm the specifications of the model selected. Warranty Service Refrigerated Cooling 1300 526 477 seeleyinternational.com...
Need help?
Do you have a question about the Braemar XE71-42G and is the answer not in the manual?
Questions and answers