(size 3). Door opening and closing cycles, including opening speed, back check speed, hold open time delay, closing speed, and latch position are all adjustable. CAUTION Always disconnect mains power to the operator prior to servicing or cleaning 2/15 Relcross Door Controls | E: sales@relcross.co.uk | T: 44(0)1380 729600...
2.9 When Pre-Install & Product Check is complete go to: 3 OPERATOR INSTALLATION. Clearances for Pull System Clearances for Push System 3/15 Relcross Door Controls | E: sales@relcross.co.uk | T: 44(0)1380 729600...
NOTE: For push units with a reveal greater than 152mm you will need to purchase an extended arm Header Frame & Door Preparation: Pull System HIGH VOLTAGE CONDUIT Ø22 4/15 Relcross Door Controls | E: sales@relcross.co.uk | T: 44(0)1380 729600 Relcross Door Controls | E: sales@relcross.co.uk | T: 44(0)1380 729600...
Do not connect any remote activating device to the door unless it is located within line of sight of the door. When the wiring is complete go to 5 ARM & COVER INSTALLATION. 5/15 Relcross Door Controls | E: sales@relcross.co.uk | T: 44(0)1380 729600...
Turn off the power operator switch - the door closes. Remove the jumper from the control box T27, T28. When arm installation is complete go to 6 OPERATOR ADJUSTMENT 6/15 Relcross Door Controls | E: sales@relcross.co.uk | T: 44(0)1380 729600...
(P5) where the speed is decreased automatically by the control box allowing the door to close smoothly until fully closed. 6.2.6 If the door does not open at all during learning cycle: Check the door for binding. 7/15 Relcross Door Controls | E: sales@relcross.co.uk | T: 44(0)1380 729600...
Page 9
The door should stop and then slowly drive to the fully opening position The point at which the safety device becomes inactive can be adjusted via P8 from closed position up to back check position 8/15 Relcross Door Controls | E: sales@relcross.co.uk | T: 44(0)1380 729600...
Page 10
P7 from open position up to a few degrees of closed position NOTE Adjust operator in accordance with EN16005 be it for power assisted low energy power operated doors 9/15 Relcross Door Controls | E: sales@relcross.co.uk | T: 44(0)1380 729600...
Then go to 8 RELEASE FOR SERVIVE. 7.1 CONTROL BOX: POTENTIOMETERS & SWITCHES 7.4OTE POWER BOOST ADJ CONT 5 SECS POWER BOOST ACT PUSH & GO MONITORED SAFETY Relcross Door Controls | E: sales@relcross.co.uk | T: 44(0)1380 729600 10/15...
Page 12
Fire Alarm Door Open on fire alarm and remain electrically unlocked (if locking present) Key Switch Off BESPOKE SOLUTION - ALLEGION T22, T23 Two Way 9, A-F NOT IN USE Relcross Door Controls | E: sales@relcross.co.uk | T: 44(0)1380 729600 11/15...
Page 13
Activation closed - used for high wind situations Enables power boost to operate Power Boost continuously or for 5 seconds only Continuous 5 Seconds Adjustment after the door closes Relcross Door Controls | E: sales@relcross.co.uk | T: 44(0)1380 729600 12/15...
Page 14
7.4 WIRING DIAGRAM INCLUDING TERMINALS Relcross Door Controls | E: sales@relcross.co.uk | T: 44(0)1380 729600 13/15...
Instruct the owner or people in charge who and where to call for service and maintenance when required. IMPORT IMPORTANT Make sure to install all safety, traffic control and instruction decals on the door as required Relcross Door Controls | E: sales@relcross.co.uk | T: 44(0)1380 729600 15/15...