GENERAL DESCRIPTION: Our solid state timers are capable of switching from one (1) to ten (10) independent outputs. Each of the outputs has a switching capacity of 1 Amp at 120 VAC. By relocating the program wire from Position #10 (on the Timer) to the number of positions desired, the timer will pulse only from Position #1 through the programmed number.
Page 4
ELECTRICAL WIRING: Connect 120VAC supply to HI (TERMINAL 14) and NEUTRAL (TERMINAL 13). Connect one side of each valve to the COMMON (TERMINAL 11), sequentially. Connect the other side of each solenoid valve to the SWITCHED OUTPUTS (TERMINAL 1 through 10), sequentially. 4.
Page 5
120 VAC 60 HZ INPUT POWER 120 VAC SWITCHED OUTPUTS TO SOLENOIDS (120 VAC HI) SOLENOID COMMON (120 VAC N) PHYSICAL DIM. 5.5" X 7" MOUNTING DIM: E10CH1, 10 POSITION TIMER 5" X 6.5" CONTINOUS CLEANING WITH OPTION FOR HOLD-OFF HEWITT NJ 07421...