[1] TROUBLE SHOOTING FLOWCHART
Check R701.
Check D751, IC702, D750
and IC703.
Service Manual
NO RASTER
Check F701.
Check T701 pin (17) voltage
(Approx. 310V at 220V AC)
Check Secondary Main+B
(Approx. 130V)
Check CRT connector K-
wire and the signal on it.
Check 185V
Check
Bias on
IC801.
CRT board.
Does horizontal circuit
oscillate ?
Check Q601 and Q602.
5 – 1
Blown out.
Replace the fuse.
The fuse is blown out again.
Check IC701, D701 and
C705.
Check Q752 for 8V regulator
circuit and Q751, Q754 for
5V regulator circuit.