Need help?

Do you have a question about the 50/50P and is the answer not in the manual?

Questions and answers

Summary of Contents for Apex Digital 50/50P

  • Page 1 APEX Water Filters Pure water in every drop APEX- 50/50P APEX -100/100P APEX - ALK6ST Quick Setup Guide Treat your body to pure goodness with Apex filtered water...
  • Page 2 FIGURE #1 A Water supply adapter valve H Pre-filter sump B Cold water shut-off valve J Pre-carbon filter sumps C Hot water shut-off valve K User friendly wrench D Auxiliary faucet with handle in closed position L Membrane assembly E Garbage disposal M Auto shut-off valve F Drain Saddle N Post-filter...
  • Page 3: Mounting The Faucet

    4) For Stainless Steel Sink: Before using a ½” carbide 1) Disconnect the threaded nut at the connection and thread the water supply adapter, with the flat washer drill bit, an indent should be made with a center punch and cone washer in place, onto the connection and to keep the drill bit from moving.
  • Page 4: Drain Clamp Installation

    DRAIN CLAMP INSTALLATION POSITIONING THE SYSTEM 1) The drain clamp assembly should be installed above 1) The head assembly will stand up in the sink cabinet or can be hung on screws provided. the trap and on the vertical or horizontal tailpiece (Fig. #5) 2) The storage tan k may be laid on its side.
  • Page 5: Start-Up Procedure

    2) GAC and Carbon Block:Designed to remove START-UP PROCEDURE chlorine form the water supply, as well as organic and inorganic substance before entering the TFC membrane (average life 12 months). 1) Check to see all connections are made. 3)Post-Carbon: The post-filter should be changed 2) Check that the pre-filter and pre-carbon sumps are when you experience an unusual taste and/or odor to secure using the housing wrench provided.
  • Page 6: Changing The Membrane

    CHANGING THE MEMBRANE Replacement TFC membranes come with complete changing instructions when ordered. TROUBLESHOOTING LEAKS 1) Filter sump: The O-ring in the sump may not be making firm contact, have dirt or hair on it or be stretched. Clean or replace O-ring and tighten sump to make firm contact with cap. 2) Fitting Connection: Compression - Check that the fitting is tightened with all parts in proper place (refer to Fig.