AL-238
PPROGRAMMING GUIDE
AL-238P
Installation Manual

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AL-238P and is the answer not in the manual?

Questions and answers

Summary of Contents for Alean AL-238P

  • Page 1 AL-238 PPROGRAMMING GUIDE AL-238P Installation Manual...
  • Page 2: Table Of Contents

    AL-238 PPROGRAMMING GUIDE Contents Part 1 General description ................................... 3 1. AL-238P main function ................................3 2.System wiring instructions ............................... 5 3. Main board LED lights status description ..........................8 4.Main parts description ................................9 Part 2 System Operation Instruction ..............................11 1.User operation guide................................
  • Page 3: Part 1 General Description

    It is an ideal choice for installing anti-theft alarm equipment in homes, business places, financial systems and other units. 1. AL-238P main function 1.1、 Features ...
  • Page 4 AL-238 PPROGRAMMING GUIDE  Intelligent voice prompts, support for arming and disarming, programming, alarm voice broadcast, and zone broadcast content synchronization zone name (use "local control panel name" + "zone name" + "alarm" combination). Voices include local broadcasts and user phone voice broadcasts. Support remote reminders, off duty reminders and warning reminders for networked alarm users.
  • Page 5: System Wiring Instructions

    Siren 2.2.AL-238P connection to the power supply AL-238P adopts wide voltage design, can withstand DC12-24V power supply (factory standard DC13.8V 3A power supply); it will prompt the system under voltage,when the power supply voltage is lower than 10V; 2.3.AL-238P and the keypad connection The VCC, A, B, and GND of the keypad correspond to the red, green, yellow, and black terminals of the master keypad, and up to 8 keypads are connected.
  • Page 6 AL-238 PPROGRAMMING GUIDE 2.4.AL-238P connection to wired detector The AL-238P series control panel can connect up to 8 wired detectors, and supports 4 kinds of zone wiring methods. The specific connection method is as follows: 1、NC wired detector 2、NO wired detector 3、With 2.2K NO wired...
  • Page 7 BC of JP2 As shown in FIG:  Plugged-in AB and CD of JP2 jumper of AL-238P panel, the siren interface is active output, and the output power consumption is DC12V 2000mA;  Plugged-in BC of JP2 jumper of AL-238P panel, the siren interface is passive output;...
  • Page 8: Main Board Led Lights Status Description

    AL-238 PPROGRAMMING GUIDE DC power supply-2 Keypad interface 8 zones expansion 16-output module Partition keypad module(address 0-4) (address 64-66) (address 1-7) GrnYel Blk Red Grn yel Blk 8 zones expansion module address dial code description: the address dial code range is 0-4; the address dial 0, the zone number represents 1-8 zone, dial 1 represents 9-16 zone, and so on;...
  • Page 9: Main Parts Description

    AL-238 PPROGRAMMING GUIDE 4.Main parts description 4.1.Keypad Keypad layout: The keypad is mainly divided into two areas: the display area and the keypad area. The keypad display area shows the running status of the control panel: such as arm, alarm, communication , power supply, program, bypass, and zone. The keypad area is mainly divided into: password input and programming command input, system arming, disarming, staying arming, bypass and other function buttons.。...
  • Page 10 AL-238 PPROGRAMMING GUIDE when there is no data, the light is off; LED4=Send indicator: When the module serial port sends data, the light is on; when there is no data, the light is off; LED5=Network indicator: Long flashing once every 3s: successful registration of the network;...
  • Page 11: Part 2 System Operation Instruction

    AL-238 PPROGRAMMING GUIDE Part 2 System Operation Instruction 1.User operation guide 1.1 .Arming Keypad arming: password(123456) + “ARM ” key Remote controller arming: Press“ ”key After right operation, control panel sounds di…di…di…, wait till control panel delay arming time is up(10s), and the arming succeeds.
  • Page 12: System Programming Instruction

    AL-238 PPROGRAMMING GUIDE 1.10.Keypad lock and unlock If keypad locked function is turned on, keypad disarming operates 3 times error password, and enters locked status. Only beep when you press any key. The keypad will unlock automatically after15 minutes or cut off the control panel and restart. 1.11.Recovery keypad programming password is123456 <1>.
  • Page 13: Attachment 2

    AL-238 PPROGRAMMING GUIDE Query Query alarm record Input format:00+N(01~06); N means programming address 01~06,that is: various record Query operation record numbers; Query system AC supply, Press 1 to previous, press 2 to next expand module and query, press 0 to repeat.*#to exit.
  • Page 14 AL-238 PPROGRAMMING GUIDE Arm&Disarm 99999999(8 the first two digits means hour(s), timing setting digits) the last two digits means minute(s); 6 time setting YYYY means disarming time,the first two digits means hour(s), the last two digits means minute(s); More than 23:59 is invalid Default factory value is 99999999.
  • Page 15 AL-238 PPROGRAMMING GUIDE Attribute of 111(3 digits) X indicates the type of zone:0:Shield zone 40 zone;1:instantaneous zone;2: delay zone;3:24-hour zone;4:fire zone;5:blank;6:temperature sensing zone 7:ambulance zone; 8:Trigger the arm and disarm zone (When triggered, the panel arming , triggers again the panel disarming ) 9:Intelligent arming and disarming the zone (if the zone is not triggered for a long time, the panel will automatically...
  • Page 16 AL-238 PPROGRAMMING GUIDE wireless code, the operations are as below: input: 09+01+1+#, when" wireless self-learning entry" is heard, to trigger wireless detector twice, each time interval more than 2 seconds, the prompt "wireless self- learning success" twice indicating successful learning.If you want to delete the wireless code of zone 1, then input: 09+01+9+#...
  • Page 17 AL-238 PPROGRAMMING GUIDE 11+01+9+#, and it will prompt "Operation successful"; Time 010(3 digits) Input Format: settings 12+01+XXX+# System alarm XXX means alarm time is 000-999s, time default factory value is 010s 010(3 digits) Input Format: 12+02+XXX+# Keypad arming XXX means keypad arming time is 000- delay 999s,default factory value is 010s.
  • Page 18 AL-238 PPROGRAMMING GUIDE Function instruction: If this function is enabled, the master keypad buzzer will sound every 10 seconds when the system is under voltage until the voltage is restored. If the function is off, it won’t prompt. 0(1 digit) Input Format:12+04+X+# X indicates:...
  • Page 19 AL-238 PPROGRAMMING GUIDE disarming disconnects. 5:Linking alarm (pulse output), disarming disconnects. 6:Alarm linkage (pulse output) (following the alarm time of control panel), disarming disconnects. Default factory PMG1 is 0, PMG2 is 1. Extended d Number of alarm Extended device settings (reserved) 0 (1 digit)...
  • Page 20 AL-238 PPROGRAMMING GUIDE plus the phone number plus # before entering the phone number; For example: the group outgoing number is 0, use the number 1 to dial the user's phone: Input in programming state 18+01+0+*+user number+# Note: "*" means waiting for 1 second. Each additional "*"...
  • Page 21 AL-238 PPROGRAMMING GUIDE Center 4 upload r 0 (1 digit) eport content setti Call center 000000-999999 002000 (6 digit Call center accoun account s) Call center The system regula 0000-9999 hours; when 0000 hours d 0000 (4 digits) heartbeat r rly sends online h o not report eport...
  • Page 22 AL-238 PPROGRAMMING GUIDE 000.000.000.000 IP address: Each digit in the IP address GPRS center IP must be entered with 3 digits (such as address 192.168.001.002), as long as you enter 192.168.001.001 Gateway 12 digits, you do not need to enter the 255.255.255.000 Subnet mask dot in the middle.
  • Page 23 AL-238 PPROGRAMMING GUIDE long beep to restore successfully) Printer Operation print 1(1 digit) Input format: 45+01+X+#’’ settings or not X means: 0=prohibit; 1=allow; Whether the fault is 0(1 digit) Input format: 45+02+X+# printed X means: 0=prohibit; 1=allow; Whether to print 0(1 digit)...
  • Page 24: Programming Example

    AL-238 PPROGRAMMING GUIDE 550003 Partition 3 (6 digits)+# password N represents programming address 01~05, that is, 5 partitions; 550004 Partition 4 password 550005 Partition 5 password Partition remote control 1 Assign the remote control to partition 1, remote arm and disarm through the remote control 1 control;...
  • Page 25: Part 3.Zone Type And Password Permission Description

    AL-238 PPROGRAMMING GUIDE E.g. 4: To modify the Zone1 attribute to 24 hours and be a silent zone, enter the programming mode and input: 07+01+300+# ,the buzzer will beeps once after modification. E.g. 5: To modify control panel own wired zone attribute of terminal 2 to NO (Normally open). Enter the programming and input:05+02+2+#, the buzzer will beeps once after modification.
  • Page 26: System Password Permission Description

    AL-238 PPROGRAMMING GUIDE Fire zone: Regardless of arming or not, while the zones are active, it will alarm as soon as it is triggered. Temperature sensing zone: Regardless of arming or not, while the zones are active, it will alarm as soon as it is triggered Panic zone:...
  • Page 27: The User Telephone Alarm Notice

    AL-238 PPROGRAMMING GUIDE host will broadcast the previous configuration information, if you need to modify it, directly enter the new IP and press # to save;  The IP address of center 1, format: 34+02+021052118056# (IP address of the computer or cloud server where the software is installed) ...
  • Page 28 AL-238 PPROGRAMMING GUIDE 6.Serial port connection printer 1. The panel has a real-time printing function. The information that can be printed includes: alarms, faults, operations, and equipment normal online information. By default, the zone alarm and arming and disarming operations are printed, and the printing has time records.
  • Page 29: Address Code List

    AL-238 PPROGRAMMING GUIDE Address code list Explanation 1、 DIP switch setting , ”ON” means “1”, refer to “●”,”OFF” means “0”...