Huw Jones
February 18, 2025

I have a Even Sprey Club. I have an intermittent fault when the pump stops. I have renewed the operating switch, to no avail. Is there a wiring diagram so that I can trace and eliminate the fault. Thank you. Huw Jones

1 comments:
Mr. Anderson
May 14, 2025

Yes, a spare parts diagram is available for the Vitax EvenSprey CLUB, which includes components such as the pump, loom, switch, and handlebar unit. This diagram can help trace and eliminate an intermittent fault with the pump.

This answer is automatically generated

Subscribe to Our Youtube Channel

Summary of Contents for Vitax Supaturf EvenSprey CLUB

  • Page 1 EvenSprey CLUB Operator Manual...
  • Page 2 Council Directives” concerned with the supply of machinery compatibility. No alterations are to be made to the machine without the prior consultation and approval of Vitax Limited otherwise this Declaration may become invalid. This equipment must be commissioned, used and maintained strictly in accordance with the operating and maintenance instructions issued with the machine.
  • Page 3 INTRODUCTION IMPORTANT - PLEASE READ THIS MANUAL BEFORE USE This is essential if you are to learn how to operate this equipment correctly. Failure to do so could result in personal injury or equipment damage. This manual should be considered a permanent part of the equipment and should remain with the machinery if sold on.
  • Page 4 EvenSprey CLUB Machine Assembly The EvenSprey CLUB (both 3 nozzle boom option and hand lance option) comes ready for use. The machine is packed with a tank filter in the neck of the tank to prevent debris from inadvertently entering the tank when filling.
  • Page 5 EvenSprey CLUB Hand Lance Assembly To attach the hand lance, disconnect the 12mm tubing from the pump outlet (see bottom right pic) and simply attach the coiled hose into this fitting. The hand lance can be used whilst the spray boom is attached to the boom mount.
  • Page 6 Nozzle Overlap Flat fan spray nozzles are designed to overlap. For accurate spraying it is recommended using a spray pattern indicator, which allows the operator to see clearly the area covered. Hand Lance Information During hand lance operation, the pump is designed to stop when the Hand Lance trigger is in the 'Off' position.
  • Page 7 Cleaning It is recommended that the machine pipe work, strainers and nozzle filters are thoroughly washed out after every use to avoid cross contamination of products and to extend the pump life. Follow the instructions printed on the side of the tank. These instructions are duplicated below: 1.
  • Page 8 If the calibration tests show the output to be below 7% of the results shown in the spray guide table, contact Vitax on the technical service line. How to Check Walking Speed to Maximise Spray Accuracy The EvenSprey CLUB is designed to give a constant output at all times.
  • Page 9 EvenSprey CLUB Spare Parts Listing Order Code Description 04700 PUMP 00227 BATTERY 00274 SWITCH 00337 LOOM 00201 HANDLEBAR UNIT COMPLETE WITH LOOM & BRACKET TO HOLD SWITCH 8” BASKET FILTER 14006 8” TANK LID 14005 12077 10MM TANK OUTLET ELBOW BATTERY CHARGER –...
  • Page 10 EvenSprey CLUB Spare Parts Diagram 00274 00201 14005 14006 15206 12005 12077 11373 00227 00236 04700 00337 15196 04500 15216 15195...
  • Page 11 NOTES...